Endpoint Manager

Description

Product name

endpoint_manager

CVE-2025-22459 (GCVE-0-2025-22459)
Vulnerability from
Published
2025-04-08 14:25
Modified
2025-04-08 15:37
CWE
  • CWE-296 - Improper Following of a Certificate's Chain of Trust
Summary
Improper certificate validation in Ivanti Endpoint Manager before version 2024 SU1 or before version 2022 SU7 allows a remote unauthenticated attacker to intercept limited traffic between clients and servers.
Impacted products
Vendor Product Version
Ivanti Endpoint Manager Patch: 2024 SU1
Patch: 2022 SU7
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-22459",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-08T15:24:28.541549Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-08T15:37:26.132Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Endpoint Manager",
          "vendor": "Ivanti",
          "versions": [
            {
              "status": "unaffected",
              "version": "2024 SU1",
              "versionType": "custom"
            },
            {
              "status": "unaffected",
              "version": "2022 SU7",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eImproper certificate validation\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e in \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eIvanti Endpoint Manager before version 2024 SU1 or before version 2022 SU7\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e allows a \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eremote\u003c/span\u003e \u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eunauthenti\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ec\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eate\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ed \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eattacker \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eto intercept limited traffic between clients and servers.\u003c/span\u003e"
            }
          ],
          "value": "Improper certificate validation in Ivanti Endpoint Manager before version 2024 SU1 or before version 2022 SU7 allows a remote unauthenticated attacker to intercept limited traffic between clients and servers."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-117",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-117 Interception"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-296",
              "description": "CWE-296: Improper Following of a Certificate\u0027s Chain of Trust",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-08T14:25:57.827Z",
        "orgId": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
        "shortName": "ivanti"
      },
      "references": [
        {
          "url": "https://forums.ivanti.com/s/article/Security-Advisory-EPM-April-2025-for-EPM-2024-and-EPM-2022-SU6"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
    "assignerShortName": "ivanti",
    "cveId": "CVE-2025-22459",
    "datePublished": "2025-04-08T14:25:57.827Z",
    "dateReserved": "2025-01-07T02:19:22.797Z",
    "dateUpdated": "2025-04-08T15:37:26.132Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-22464 (GCVE-0-2025-22464)
Vulnerability from
Published
2025-04-08 14:27
Modified
2025-04-08 15:04
CWE
  • CWE-822 - Untrusted Pointer Dereference
Summary
An untrusted pointer dereference vulnerability in Ivanti Endpoint Manager before version 2024 SU1 or before version 2022 SU7 allows an attacker with local access to write arbitrary data into memory causing a denial-of-service condition.
Impacted products
Vendor Product Version
Ivanti Endpoint Manager Patch: 2024 SU1
Patch: 2022 SU7
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-22464",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-08T14:58:16.739481Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-08T15:04:45.498Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Endpoint Manager",
          "vendor": "Ivanti",
          "versions": [
            {
              "status": "unaffected",
              "version": "2024 SU1",
              "versionType": "custom"
            },
            {
              "status": "unaffected",
              "version": "2022 SU7",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn untrusted pointer dereference vulnerability in Ivanti Endpoint Manager before version 2024 SU1 or before version 2022 SU7 allows an attacker with local access to write arbitrary data into memory causing a denial-of-service condition.\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003c/span\u003e"
            }
          ],
          "value": "An untrusted pointer dereference vulnerability in Ivanti Endpoint Manager before version 2024 SU1 or before version 2022 SU7 allows an attacker with local access to write arbitrary data into memory causing a denial-of-service condition."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-129",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-129 Pointer Manipulation"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-822",
              "description": "CWE-822: Untrusted Pointer Dereference",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-08T14:27:03.158Z",
        "orgId": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
        "shortName": "ivanti"
      },
      "references": [
        {
          "url": "https://forums.ivanti.com/s/article/Security-Advisory-EPM-April-2025-for-EPM-2024-and-EPM-2022-SU6"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
    "assignerShortName": "ivanti",
    "cveId": "CVE-2025-22464",
    "datePublished": "2025-04-08T14:27:03.158Z",
    "dateReserved": "2025-01-07T02:19:27.271Z",
    "dateUpdated": "2025-04-08T15:04:45.498Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-22465 (GCVE-0-2025-22465)
Vulnerability from
Published
2025-04-08 14:27
Modified
2025-04-08 14:52
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Summary
Reflected XSS in Ivanti Endpoint Manager before version 2024 SU1 or before version 2022 SU7 allows a remote unauthenticated attacker to execute arbitrary javascript in a victim's browser. Unlikely user interaction is required.
Impacted products
Vendor Product Version
Ivanti Endpoint Manager Patch: 2024 SU1
Patch: 2022 SU7
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-22465",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-08T14:52:33.435771Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-08T14:52:54.418Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Endpoint Manager",
          "vendor": "Ivanti",
          "versions": [
            {
              "status": "unaffected",
              "version": "2024 SU1",
              "versionType": "custom"
            },
            {
              "status": "unaffected",
              "version": "2022 SU7",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eReflected XSS in Ivanti Endpoint Manager before version 2024 SU1 or before version 2022 SU7 allows a remote unauthenticated attacker to \u003c/span\u003e\u003cspan style=\"background-color: transparent;\"\u003eexecute arbitrary javascript in a victim\u0027s browser. Unlikely \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003euser interaction is required.\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003c/span\u003e"
            }
          ],
          "value": "Reflected XSS in Ivanti Endpoint Manager before version 2024 SU1 or before version 2022 SU7 allows a remote unauthenticated attacker to execute arbitrary javascript in a victim\u0027s browser. Unlikely user interaction is required."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-591",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-591 Reflected XSS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-08T14:27:27.199Z",
        "orgId": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
        "shortName": "ivanti"
      },
      "references": [
        {
          "url": "https://forums.ivanti.com/s/article/Security-Advisory-EPM-April-2025-for-EPM-2024-and-EPM-2022-SU6"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
    "assignerShortName": "ivanti",
    "cveId": "CVE-2025-22465",
    "datePublished": "2025-04-08T14:27:27.199Z",
    "dateReserved": "2025-01-07T02:19:27.271Z",
    "dateUpdated": "2025-04-08T14:52:54.418Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-22466 (GCVE-0-2025-22466)
Vulnerability from
Published
2025-04-08 14:27
Modified
2025-04-08 14:46
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Summary
Reflected XSS in Ivanti Endpoint Manager before version 2024 SU1 or before version 2022 SU7 allows a remote unauthenticated attacker to obtain admin privileges. User interaction is required.
Impacted products
Vendor Product Version
Ivanti Endpoint Manager Patch: 2024 SU1
Patch: 2022 SU7
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-22466",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-08T14:46:11.382026Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-08T14:46:25.244Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Endpoint Manager",
          "vendor": "Ivanti",
          "versions": [
            {
              "status": "unaffected",
              "version": "2024 SU1",
              "versionType": "custom"
            },
            {
              "status": "unaffected",
              "version": "2022 SU7",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eReflected XSS in Ivanti Endpoint Manager before version 2024 SU1 or before version 2022 SU7 allows a remote unauthenticated attacker to obtain admin privileges. User interaction is required.\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003c/span\u003e"
            }
          ],
          "value": "Reflected XSS in Ivanti Endpoint Manager before version 2024 SU1 or before version 2022 SU7 allows a remote unauthenticated attacker to obtain admin privileges. User interaction is required."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-591",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-591 Reflected XSS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-08T14:27:55.834Z",
        "orgId": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
        "shortName": "ivanti"
      },
      "references": [
        {
          "url": "https://forums.ivanti.com/s/article/Security-Advisory-EPM-April-2025-for-EPM-2024-and-EPM-2022-SU6"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
    "assignerShortName": "ivanti",
    "cveId": "CVE-2025-22466",
    "datePublished": "2025-04-08T14:27:55.834Z",
    "dateReserved": "2025-01-07T02:19:27.271Z",
    "dateUpdated": "2025-04-08T14:46:25.244Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-22058 (GCVE-0-2024-22058)
Vulnerability from
Published
2024-05-31 17:38
Modified
2025-03-17 15:41
Summary
A buffer overflow allows a low privilege user on the local machine that has the EPM Agent installed to execute arbitrary code with elevated permissions in Ivanti EPM 2021.1 and older.
Impacted products
Vendor Product Version
Ivanti EPM Version: 2021    2021
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-22058",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-07T16:26:52.175727Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-122",
                "description": "CWE-122 Heap-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-17T15:41:54.663Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T22:35:34.747Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://forums.ivanti.com/s/article/CVE-2024-22058-Privilege-Escalation-for-Ivanti-Endpoint-Manager-EPM"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "EPM",
          "vendor": "Ivanti",
          "versions": [
            {
              "lessThanOrEqual": "2021",
              "status": "affected",
              "version": "2021",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A buffer overflow allows a low privilege user on the local machine that has the EPM Agent installed to execute arbitrary code with elevated permissions in Ivanti EPM 2021.1 and older."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-31T17:38:31.334Z",
        "orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
        "shortName": "hackerone"
      },
      "references": [
        {
          "url": "https://forums.ivanti.com/s/article/CVE-2024-22058-Privilege-Escalation-for-Ivanti-Endpoint-Manager-EPM"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
    "assignerShortName": "hackerone",
    "cveId": "CVE-2024-22058",
    "datePublished": "2024-05-31T17:38:31.334Z",
    "dateReserved": "2024-01-05T01:04:06.642Z",
    "dateUpdated": "2025-03-17T15:41:54.663Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-10811 (GCVE-0-2024-10811)
Vulnerability from
Published
2025-01-14 16:59
Modified
2025-03-08 04:55
Severity ?
CWE
  • CWE-36 - Absolute Path Traversal
Summary
Absolute path traversal in Ivanti EPM before the 2024 January-2025 Security Update and 2022 SU6 January-2025 Security Update allows a remote unauthenticated attacker to leak sensitive information.
Impacted products
Vendor Product Version
Ivanti Endpoint Manager Patch: 2024 January-2025 Security Update
Patch: 2022 SU6 January-2025 Security Update
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-10811",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-23T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-08T04:55:14.273Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://www.horizon3.ai/attack-research/attack-blogs/ivanti-endpoint-manager-multiple-credential-coercion-vulnerabilities/"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Endpoint Manager",
          "vendor": "Ivanti",
          "versions": [
            {
              "status": "unaffected",
              "version": "2024 January-2025 Security Update",
              "versionType": "custom"
            },
            {
              "status": "unaffected",
              "version": "2022 SU6 January-2025 Security Update",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAbsolute path traversal in Ivanti EPM before the 2024 January-2025 Security Update and 2022 SU6 January-2025 Security Update allows a remote unauthenticated attacker to leak sensitive information.\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003c/span\u003e"
            }
          ],
          "value": "Absolute path traversal in Ivanti EPM before the 2024 January-2025 Security Update and 2022 SU6 January-2025 Security Update allows a remote unauthenticated attacker to leak sensitive information."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-597",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-597 Absolute Path Traversal"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-36",
              "description": "CWE-36 Absolute Path Traversal",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-01-14T16:59:32.982Z",
        "orgId": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
        "shortName": "ivanti"
      },
      "references": [
        {
          "url": "https://forums.ivanti.com/s/article/Security-Advisory-EPM-January-2025-for-EPM-2024-and-EPM-2022-SU6"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
    "assignerShortName": "ivanti",
    "cveId": "CVE-2024-10811",
    "datePublished": "2025-01-14T16:59:32.982Z",
    "dateReserved": "2024-11-04T18:01:19.410Z",
    "dateUpdated": "2025-03-08T04:55:14.273Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-13162 (GCVE-0-2024-13162)
Vulnerability from
Published
2025-01-14 17:23
Modified
2025-01-24 04:55
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
SQL injection in Ivanti EPM before the 2024 January-2025 Security Update and 2022 SU6 January-2025 Security Update allows a remote authenticated attacker with admin privileges to achieve remote code execution. This CVE addresses incomplete fixes from CVE-2024-32848.
Impacted products
Vendor Product Version
Ivanti Endpoint Manager Patch: 2024 January-2025 Security Update
Patch: 2022 SU6 January-2025 Security Update
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-13162",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-23T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-24T04:55:58.303Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Endpoint Manager",
          "vendor": "Ivanti",
          "versions": [
            {
              "status": "unaffected",
              "version": "2024 January-2025 Security Update",
              "versionType": "custom"
            },
            {
              "status": "unaffected",
              "version": "2022 SU6 January-2025 Security Update",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eSQL injection in Ivanti EPM before the 2024 January-2025 Security Update and 2022 SU6 January-2025 Security Update allows a remote authenticated attacker with admin privileges to achieve remote code execution. \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThis CVE addresses incomplete fixes from CVE-2024-32848.\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003c/span\u003e"
            }
          ],
          "value": "SQL injection in Ivanti EPM before the 2024 January-2025 Security Update and 2022 SU6 January-2025 Security Update allows a remote authenticated attacker with admin privileges to achieve remote code execution. This CVE addresses incomplete fixes from CVE-2024-32848."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-66",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-66 SQL Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-01-14T17:23:48.256Z",
        "orgId": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
        "shortName": "ivanti"
      },
      "references": [
        {
          "url": "https://forums.ivanti.com/s/article/Security-Advisory-EPM-January-2025-for-EPM-2024-and-EPM-2022-SU6"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
    "assignerShortName": "ivanti",
    "cveId": "CVE-2024-13162",
    "datePublished": "2025-01-14T17:23:48.256Z",
    "dateReserved": "2025-01-07T02:28:48.487Z",
    "dateUpdated": "2025-01-24T04:55:58.303Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-13163 (GCVE-0-2024-13163)
Vulnerability from
Published
2025-01-14 17:23
Modified
2025-01-24 04:55
CWE
  • CWE-502 - Deserialization of Untrusted Data
Summary
Deserialization of untrusted data in Ivanti EPM before the 2024 January-2025 Security Update and 2022 SU6 January-2025 Security Update allows a remote unauthenticated attacker to achieve remote code execution. Local user interaction is required.
Impacted products
Vendor Product Version
Ivanti Endpoint Manager Patch: 2024 January-2025 Security Update
Patch: 2022 SU6 January-2025 Security Update
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-13163",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-23T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-24T04:55:56.946Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Endpoint Manager",
          "vendor": "Ivanti",
          "versions": [
            {
              "status": "unaffected",
              "version": "2024 January-2025 Security Update",
              "versionType": "custom"
            },
            {
              "status": "unaffected",
              "version": "2022 SU6 January-2025 Security Update",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDeserialization of untrusted data in Ivanti EPM before the 2024 January-2025 Security Update and 2022 SU6 January-2025 Security Update allows a remote unauthenticated attacker to achieve remote code execution. Local user interaction is required.\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003c/span\u003e"
            }
          ],
          "value": "Deserialization of untrusted data in Ivanti EPM before the 2024 January-2025 Security Update and 2022 SU6 January-2025 Security Update allows a remote unauthenticated attacker to achieve remote code execution. Local user interaction is required."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-586",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-586 Object Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-502",
              "description": "CWE-502 Deserialization of Untrusted Data",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-01-14T17:23:13.781Z",
        "orgId": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
        "shortName": "ivanti"
      },
      "references": [
        {
          "url": "https://forums.ivanti.com/s/article/Security-Advisory-EPM-January-2025-for-EPM-2024-and-EPM-2022-SU6"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
    "assignerShortName": "ivanti",
    "cveId": "CVE-2024-13163",
    "datePublished": "2025-01-14T17:23:13.781Z",
    "dateReserved": "2025-01-07T02:28:50.799Z",
    "dateUpdated": "2025-01-24T04:55:56.946Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-13164 (GCVE-0-2024-13164)
Vulnerability from
Published
2025-01-14 17:22
Modified
2025-01-24 04:55
CWE
  • CWE-908 - Use of Uninitialized Resource
Summary
An uninitialized resource in Ivanti EPM before the 2024 January-2025 Security Update and 2022 SU6 January-2025 Security Update allows a local authenticated attacker to escalate their privileges.
Impacted products
Vendor Product Version
Ivanti Endpoint Manager Patch: 2024 January-2025 Security Update
Patch: 2022 SU6 January-2025 Security Update
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-13164",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-23T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-24T04:55:55.615Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Endpoint Manager",
          "vendor": "Ivanti",
          "versions": [
            {
              "status": "unaffected",
              "version": "2024 January-2025 Security Update",
              "versionType": "custom"
            },
            {
              "status": "unaffected",
              "version": "2022 SU6 January-2025 Security Update",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003en uninitialized resource\u003c/span\u003e \u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ein Ivanti EPM\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e before \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ethe 2024 January-2025 Security Update and 2022 SU6 January-2025 Security Update\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e allows a \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003elocal\u003c/span\u003e \u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eauthenticated\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e attacker to \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eescalate their privileges.\u003c/span\u003e"
            }
          ],
          "value": "An uninitialized resource in Ivanti EPM before the 2024 January-2025 Security Update and 2022 SU6 January-2025 Security Update allows a local authenticated attacker to escalate their privileges."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-233",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-233 Privilege Escalation"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-908",
              "description": "CWE-908 Use of Uninitialized Resource",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-01-14T17:22:49.382Z",
        "orgId": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
        "shortName": "ivanti"
      },
      "references": [
        {
          "url": "https://forums.ivanti.com/s/article/Security-Advisory-EPM-January-2025-for-EPM-2024-and-EPM-2022-SU6"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
    "assignerShortName": "ivanti",
    "cveId": "CVE-2024-13164",
    "datePublished": "2025-01-14T17:22:49.382Z",
    "dateReserved": "2025-01-07T02:28:51.714Z",
    "dateUpdated": "2025-01-24T04:55:55.615Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-13169 (GCVE-0-2024-13169)
Vulnerability from
Published
2025-01-14 17:18
Modified
2025-01-24 04:55
CWE
  • CWE-125 - Out-of-bounds Read
  • CWE-843 - Access of Resource Using Incompatible Type ('Type Confusion')
Summary
An out-of-bounds read in Ivanti EPM before the 2024 January-2025 Security Update and 2022 SU6 January-2025 Security Update allows a local authenticated attacker to escalate their privileges.
Impacted products
Vendor Product Version
Ivanti Endpoint Manager Patch: 2024 January-2025 Security Update
Patch: 2022 SU6 January-2025 Security Update
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-13169",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-23T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-24T04:55:54.205Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Endpoint Manager",
          "vendor": "Ivanti",
          "versions": [
            {
              "status": "unaffected",
              "version": "2024 January-2025 Security Update",
              "versionType": "custom"
            },
            {
              "status": "unaffected",
              "version": "2022 SU6 January-2025 Security Update",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn out-of-bounds read in Ivanti EPM before the 2024 January-2025 Security Update and 2022 SU6 January-2025 Security Update allows a local authenticated attacker to escalate their privileges.\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003c/span\u003e"
            }
          ],
          "value": "An out-of-bounds read in Ivanti EPM before the 2024 January-2025 Security Update and 2022 SU6 January-2025 Security Update allows a local authenticated attacker to escalate their privileges."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-233",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-233 Privilege Escalation"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125 Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-843",
              "description": "CWE-843 Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-01-14T17:18:28.069Z",
        "orgId": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
        "shortName": "ivanti"
      },
      "references": [
        {
          "url": "https://forums.ivanti.com/s/article/Security-Advisory-EPM-January-2025-for-EPM-2024-and-EPM-2022-SU6"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
    "assignerShortName": "ivanti",
    "cveId": "CVE-2024-13169",
    "datePublished": "2025-01-14T17:18:28.069Z",
    "dateReserved": "2025-01-07T02:28:56.274Z",
    "dateUpdated": "2025-01-24T04:55:54.205Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

displaying 31 - 40 organizations in total 49