Common Weakness Enumeration
Show details on NVD website
Show details on NVD website
Show details on NVD website
Show details on NVD website
Show details on NVD website
Show details on NVD website
Show details on NVD website
Show details on NVD website
Show details on NVD website
Show details on NVD website
Back to CWE stats page
CWE-121
Stack-based Buffer Overflow
A stack-based buffer overflow condition is a condition where the buffer being overwritten is allocated on the stack (i.e., is a local variable or, rarely, a parameter to a function).
CVE-2024-3879 (GCVE-0-2024-3879)
Vulnerability from cvelistv5 – Published: 2024-04-16 19:00 – Updated: 2024-08-19 18:45
VLAI
Title
Tenda W30E setcfm formSetCfm stack-based overflow
Summary
A vulnerability, which was classified as critical, was found in Tenda W30E 1.0.1.25(633). This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260913 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.260913 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.260913 | signaturepermissions-required |
| https://vuldb.com/?submit.312822 | third-party-advisory |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | W30E |
Affected:
1.0.1.25(633)
|
|
| tenda | w30e_firmware |
Affected:
1.0.1.25\(633\)
cpe:2.3:o:tenda:w30e_firmware:1.0.1.25\(633\):*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:26:56.983Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-260913 | Tenda W30E setcfm formSetCfm stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.260913"
},
{
"name": "VDB-260913 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.260913"
},
{
"name": "Submit #312822 | Tenda W30Ev1.0 V1.0.1.25(633) buffer overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.312822"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/formSetCfm.md"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:w30e_firmware:1.0.1.25\\(633\\):*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "w30e_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.0.1.25\\(633\\)"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-3879",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-19T17:33:22.591779Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-19T18:45:07.704Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "W30E",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.1.25(633)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wxhwxhwxh_mie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, was found in Tenda W30E 1.0.1.25(633). This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260913 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Tenda W30E 1.0.1.25(633) gefunden. Dabei betrifft es die Funktion formSetCfm der Datei /goform/setcfm. Durch Manipulation des Arguments funcpara1 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-16T19:00:04.934Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-260913 | Tenda W30E setcfm formSetCfm stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.260913"
},
{
"name": "VDB-260913 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.260913"
},
{
"name": "Submit #312822 | Tenda W30Ev1.0 V1.0.1.25(633) buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.312822"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/formSetCfm.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-04-16T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-04-16T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-04-16T12:55:02.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda W30E setcfm formSetCfm stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-3879",
"datePublished": "2024-04-16T19:00:04.934Z",
"dateReserved": "2024-04-16T10:49:39.590Z",
"dateUpdated": "2024-08-19T18:45:07.704Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-3881 (GCVE-0-2024-3881)
Vulnerability from cvelistv5 – Published: 2024-04-16 19:31 – Updated: 2024-08-01 20:26
VLAI
Title
Tenda W30E frmL7ProtForm frmL7PlotForm stack-based overflow
Summary
A vulnerability was found in Tenda W30E 1.0.1.25(633) and classified as critical. This issue affects the function frmL7PlotForm of the file /goform/frmL7ProtForm. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-260915. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.260915 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.260915 | signaturepermissions-required |
| https://vuldb.com/?submit.312824 | third-party-advisory |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:w30e:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "w30e",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.0.1.25\\/633\\/"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-3881",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-18T15:46:58.429046Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-03T15:34:42.267Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:26:56.424Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-260915 | Tenda W30E frmL7ProtForm frmL7PlotForm stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.260915"
},
{
"name": "VDB-260915 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.260915"
},
{
"name": "Submit #312824 | Tenda W30Ev1.0 V1.0.1.25(633) buffer overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.312824"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/frmL7ProtForm.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "W30E",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.1.25(633)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wxhwxhwxh_mie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda W30E 1.0.1.25(633) and classified as critical. This issue affects the function frmL7PlotForm of the file /goform/frmL7ProtForm. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-260915. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in Tenda W30E 1.0.1.25(633) gefunden. Davon betroffen ist die Funktion frmL7PlotForm der Datei /goform/frmL7ProtForm. Mittels Manipulieren des Arguments page mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-16T19:31:04.202Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-260915 | Tenda W30E frmL7ProtForm frmL7PlotForm stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.260915"
},
{
"name": "VDB-260915 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.260915"
},
{
"name": "Submit #312824 | Tenda W30Ev1.0 V1.0.1.25(633) buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.312824"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/frmL7ProtForm.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-04-16T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-04-16T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-04-16T12:55:05.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda W30E frmL7ProtForm frmL7PlotForm stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-3881",
"datePublished": "2024-04-16T19:31:04.202Z",
"dateReserved": "2024-04-16T10:49:45.427Z",
"dateUpdated": "2024-08-01T20:26:56.424Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-3882 (GCVE-0-2024-3882)
Vulnerability from cvelistv5 – Published: 2024-04-16 20:00 – Updated: 2024-08-01 20:26
VLAI
Title
Tenda W30E fromRouteStatic stack-based overflow
Summary
A vulnerability was found in Tenda W30E 1.0.1.25(633). It has been classified as critical. Affected is the function fromRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260916. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.260916 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.260916 | signaturepermissions-required |
| https://vuldb.com/?submit.312825 | third-party-advisory |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | W30E |
Affected:
1.0.1.25(633)
|
|
| tenda | w30e_firmware |
Affected:
1.0.1.25\(633\)
cpe:2.3:o:tenda:w30e_firmware:1.0.1.25\(633\):*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:w30e_firmware:1.0.1.25\\(633\\):*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "w30e_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.0.1.25\\(633\\)"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-3882",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-09T16:18:28.401307Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-10T16:32:20.665Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:26:57.138Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-260916 | Tenda W30E fromRouteStatic stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.260916"
},
{
"name": "VDB-260916 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.260916"
},
{
"name": "Submit #312825 | Tenda W30Ev1.0 V1.0.1.25(633) buffer overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.312825"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/fromRouteStatic.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "W30E",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.1.25(633)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wxhwxhwxh_mie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda W30E 1.0.1.25(633). It has been classified as critical. Affected is the function fromRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260916. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Tenda W30E 1.0.1.25(633) ausgemacht. Hiervon betroffen ist die Funktion fromRouteStatic der Datei /goform/fromRouteStatic. Durch das Manipulieren des Arguments page mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-16T20:00:12.433Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-260916 | Tenda W30E fromRouteStatic stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.260916"
},
{
"name": "VDB-260916 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.260916"
},
{
"name": "Submit #312825 | Tenda W30Ev1.0 V1.0.1.25(633) buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.312825"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/fromRouteStatic.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-04-16T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-04-16T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-04-16T12:55:07.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda W30E fromRouteStatic stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-3882",
"datePublished": "2024-04-16T20:00:12.433Z",
"dateReserved": "2024-04-16T10:49:48.302Z",
"dateUpdated": "2024-08-01T20:26:57.138Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-3905 (GCVE-0-2024-3905)
Vulnerability from cvelistv5 – Published: 2024-04-17 10:31 – Updated: 2024-08-01 20:26
VLAI
Title
Tenda AC500 execCommand R7WebsSecurityHandler stack-based overflow
Summary
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been classified as critical. This affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.261141 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.261141 | signaturepermissions-required |
| https://vuldb.com/?submit.313790 | third-party-advisory |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-3905",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-29T19:10:05.982005Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:31:03.283Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:26:57.134Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-261141 | Tenda AC500 execCommand R7WebsSecurityHandler stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.261141"
},
{
"name": "VDB-261141 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.261141"
},
{
"name": "Submit #313790 | Tenda AC500 V2.0.1.9(1307) buffer overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.313790"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/R7WebsSecurityHandler.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AC500",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "2.0.1.9(1307)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wxhwxhwxh_mie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been classified as critical. This affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine Schwachstelle in Tenda AC500 2.0.1.9(1307) ausgemacht. Sie wurde als kritisch eingestuft. Hiervon betroffen ist die Funktion R7WebsSecurityHandler der Datei /goform/execCommand. Dank Manipulation des Arguments password mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-17T10:31:04.297Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-261141 | Tenda AC500 execCommand R7WebsSecurityHandler stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.261141"
},
{
"name": "VDB-261141 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.261141"
},
{
"name": "Submit #313790 | Tenda AC500 V2.0.1.9(1307) buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.313790"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/R7WebsSecurityHandler.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-04-17T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-04-17T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-04-17T07:52:41.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC500 execCommand R7WebsSecurityHandler stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-3905",
"datePublished": "2024-04-17T10:31:04.297Z",
"dateReserved": "2024-04-17T05:42:30.657Z",
"dateUpdated": "2024-08-01T20:26:57.134Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-3906 (GCVE-0-2024-3906)
Vulnerability from cvelistv5 – Published: 2024-04-17 10:31 – Updated: 2024-08-01 20:26
VLAI
Title
Tenda AC500 QuickIndex formQuickIndex stack-based overflow
Summary
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.261142 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.261142 | signaturepermissions-required |
| https://vuldb.com/?submit.313801 | third-party-advisory |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:ac500:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac500",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "2.0.1.9(1307)"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-3906",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-23T18:24:41.411561Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:33:20.174Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:26:57.104Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-261142 | Tenda AC500 QuickIndex formQuickIndex stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.261142"
},
{
"name": "VDB-261142 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.261142"
},
{
"name": "Submit #313801 | Tenda AC500 V2.0.1.9(1307) buffer overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.313801"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formQuickIndex.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AC500",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "2.0.1.9(1307)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_tu (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "In Tenda AC500 2.0.1.9(1307) wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Betroffen ist die Funktion formQuickIndex der Datei /goform/QuickIndex. Mit der Manipulation des Arguments PPPOEPassword mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-17T10:31:05.641Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-261142 | Tenda AC500 QuickIndex formQuickIndex stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.261142"
},
{
"name": "VDB-261142 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.261142"
},
{
"name": "Submit #313801 | Tenda AC500 V2.0.1.9(1307) buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.313801"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formQuickIndex.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-04-17T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-04-17T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-04-17T07:52:55.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC500 QuickIndex formQuickIndex stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-3906",
"datePublished": "2024-04-17T10:31:05.641Z",
"dateReserved": "2024-04-17T05:42:39.118Z",
"dateUpdated": "2024-08-01T20:26:57.104Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-3907 (GCVE-0-2024-3907)
Vulnerability from cvelistv5 – Published: 2024-04-17 11:00 – Updated: 2024-08-01 20:26
VLAI
Title
Tenda AC500 setcfm formSetCfm stack-based overflow
Summary
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been rated as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.261143 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.261143 | signaturepermissions-required |
| https://vuldb.com/?submit.313802 | third-party-advisory |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:ac500:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac500",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "-2.0.1.9(1307)"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-3907",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-22T19:50:29.075942Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:32:54.186Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:26:57.130Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-261143 | Tenda AC500 setcfm formSetCfm stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.261143"
},
{
"name": "VDB-261143 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.261143"
},
{
"name": "Submit #313802 | Tenda AC500 V2.0.1.9(1307) buffer overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.313802"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formSetCfm.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AC500",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "2.0.1.9(1307)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_tu (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been rated as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda AC500 2.0.1.9(1307) ausgemacht. Sie wurde als kritisch eingestuft. Betroffen davon ist die Funktion formSetCfm der Datei /goform/setcfm. Durch die Manipulation des Arguments funcpara1 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-17T11:00:06.424Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-261143 | Tenda AC500 setcfm formSetCfm stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.261143"
},
{
"name": "VDB-261143 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.261143"
},
{
"name": "Submit #313802 | Tenda AC500 V2.0.1.9(1307) buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.313802"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formSetCfm.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-04-17T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-04-17T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-04-17T07:53:02.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC500 setcfm formSetCfm stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-3907",
"datePublished": "2024-04-17T11:00:06.424Z",
"dateReserved": "2024-04-17T05:42:46.647Z",
"dateUpdated": "2024-08-01T20:26:57.130Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-3909 (GCVE-0-2024-3909)
Vulnerability from cvelistv5 – Published: 2024-04-17 11:31 – Updated: 2024-08-01 20:26
VLAI
Title
Tenda AC500 execCommand formexeCommand stack-based overflow
Summary
A vulnerability classified as critical was found in Tenda AC500 2.0.1.9(1307). Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.261145 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.261145 | signaturepermissions-required |
| https://vuldb.com/?submit.313804 | third-party-advisory |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | AC500 |
Affected:
2.0.1.9(1307)
|
|
| tenda | ac500_firmware |
Affected:
2.0.1.9\(1307\)
cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\(1307\):*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac500_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "2.0.1.9\\(1307\\)"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-3909",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-22T15:10:58.576153Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:31:11.551Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:26:57.136Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-261145 | Tenda AC500 execCommand formexeCommand stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.261145"
},
{
"name": "VDB-261145 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.261145"
},
{
"name": "Submit #313804 | Tenda AC500 V2.0.1.9(1307) buffer overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.313804"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formexeCommand.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AC500",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "2.0.1.9(1307)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_tu (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as critical was found in Tenda AC500 2.0.1.9(1307). Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "In Tenda AC500 2.0.1.9(1307) wurde eine kritische Schwachstelle entdeckt. Es geht um die Funktion formexeCommand der Datei /goform/execCommand. Mittels dem Manipulieren des Arguments cmdinput mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-17T11:31:05.865Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-261145 | Tenda AC500 execCommand formexeCommand stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.261145"
},
{
"name": "VDB-261145 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.261145"
},
{
"name": "Submit #313804 | Tenda AC500 V2.0.1.9(1307) buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.313804"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formexeCommand.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-04-17T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-04-17T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-04-17T07:53:08.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC500 execCommand formexeCommand stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-3909",
"datePublished": "2024-04-17T11:31:05.865Z",
"dateReserved": "2024-04-17T05:42:53.219Z",
"dateUpdated": "2024-08-01T20:26:57.136Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-3910 (GCVE-0-2024-3910)
Vulnerability from cvelistv5 – Published: 2024-04-17 12:00 – Updated: 2024-08-01 20:26
VLAI
Title
Tenda AC500 DhcpListClient fromDhcpListClient stack-based overflow
Summary
A vulnerability, which was classified as critical, has been found in Tenda AC500 2.0.1.9(1307). Affected by this issue is the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.261146 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.261146 | signaturepermissions-required |
| https://vuldb.com/?submit.313805 | third-party-advisory |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:ac500:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac500",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "-"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-3910",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-23T19:14:35.355698Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:33:24.339Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:26:57.124Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-261146 | Tenda AC500 DhcpListClient fromDhcpListClient stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.261146"
},
{
"name": "VDB-261146 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.261146"
},
{
"name": "Submit #313805 | Tenda AC500 V2.0.1.9(1307) buffer overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.313805"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/fromDhcpListClient_page.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AC500",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "2.0.1.9(1307)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_tu (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, has been found in Tenda AC500 2.0.1.9(1307). Affected by this issue is the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in Tenda AC500 2.0.1.9(1307) entdeckt. Es geht hierbei um die Funktion fromDhcpListClient der Datei /goform/DhcpListClient. Mittels Manipulieren des Arguments page mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-17T12:00:05.651Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-261146 | Tenda AC500 DhcpListClient fromDhcpListClient stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.261146"
},
{
"name": "VDB-261146 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.261146"
},
{
"name": "Submit #313805 | Tenda AC500 V2.0.1.9(1307) buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.313805"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/fromDhcpListClient_page.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-04-17T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-04-17T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-04-17T07:53:13.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC500 DhcpListClient fromDhcpListClient stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-3910",
"datePublished": "2024-04-17T12:00:05.651Z",
"dateReserved": "2024-04-17T05:42:57.816Z",
"dateUpdated": "2024-08-01T20:26:57.124Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-39354 (GCVE-0-2024-39354)
Vulnerability from cvelistv5 – Published: 2024-11-11 14:59 – Updated: 2024-11-11 16:07
VLAI
Title
Delta Electronics DIAScreen Stack-based Buffer Overflow
Summary
If an attacker tricks a valid user into running Delta Electronics DIAScreen with a file containing malicious code, a stack-based buffer overflow in CEtherIPTagItem can be exploited, allowing the attacker to remotely execute arbitrary code.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Delta Electronics | DIAScreen |
Affected:
0 , < v1.5.0
(custom)
|
|
| deltaww | diascreen |
Affected:
0 , < 1.5.0
(custom)
cpe:2.3:a:deltaww:diascreen:*:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:deltaww:diascreen:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "diascreen",
"vendor": "deltaww",
"versions": [
{
"lessThan": "1.5.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-39354",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-11T16:07:33.279755Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-11T16:07:37.602Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "DIAScreen",
"vendor": "Delta Electronics",
"versions": [
{
"lessThan": "v1.5.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eIf an attacker tricks a valid user into running Delta Electronics DIAScreen with a file containing malicious code, a stack-based buffer overflow in CEtherIPTagItem can be exploited, allowing the attacker to remotely execute arbitrary code.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
}
],
"value": "If an attacker tricks a valid user into running Delta Electronics DIAScreen with a file containing malicious code, a stack-based buffer overflow in CEtherIPTagItem can be exploited, allowing the attacker to remotely execute arbitrary code."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-11T14:59:38.364Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-312-02"
},
{
"url": "https://www.deltaww.com/en-US/Cybersecurity_Advisory"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eDelta Electronics has released \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://diastudio.deltaww.com/home/downloads?sec=download\"\u003ev1.5.0 of DIAScreen (login required)\u003c/a\u003e\u0026nbsp;and recommends users install this update on all affected systems.\u003c/p\u003e\u003cp\u003eFor more information, please see the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.deltaww.com/en-US/Cybersecurity_Advisory\"\u003eDelta product cybersecurity advisory for these issues.\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
}
],
"value": "Delta Electronics has released v1.5.0 of DIAScreen (login required) https://diastudio.deltaww.com/home/downloads \u00a0and recommends users install this update on all affected systems.\n\nFor more information, please see the Delta product cybersecurity advisory for these issues. https://www.deltaww.com/en-US/Cybersecurity_Advisory"
}
],
"source": {
"advisory": "ICSA-24-312-02",
"discovery": "EXTERNAL"
},
"title": "Delta Electronics DIAScreen Stack-based Buffer Overflow",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2024-39354",
"datePublished": "2024-11-11T14:59:38.364Z",
"dateReserved": "2024-07-16T16:12:58.987Z",
"dateUpdated": "2024-11-11T16:07:37.602Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-39357 (GCVE-0-2024-39357)
Vulnerability from cvelistv5 – Published: 2025-01-14 14:21 – Updated: 2025-01-14 16:04
VLAI
Summary
A stack-based buffer overflow vulnerability exists in the wireless.cgi SetName() functionality of Wavlink AC3000 M33A8.V5030.210505. A specially crafted HTTP request can lead to arbitrary command execution. An attacker can make an authenticated HTTP request to trigger this vulnerability.
Severity
9.1 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Wavlink | Wavlink AC3000 |
Affected:
M33A8.V5030.210505
|
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-39357",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-14T15:35:19.963498Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-14T15:35:28.715Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-01-14T16:04:01.283Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2024-2039"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Wavlink AC3000",
"vendor": "Wavlink",
"versions": [
{
"status": "affected",
"version": "M33A8.V5030.210505"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Discovered by Lilith \u0026gt;_\u0026gt; of Cisco Talos."
}
],
"descriptions": [
{
"lang": "en",
"value": "A stack-based buffer overflow vulnerability exists in the wireless.cgi SetName() functionality of Wavlink AC3000 M33A8.V5030.210505. A specially crafted HTTP request can lead to arbitrary command execution. An attacker can make an authenticated HTTP request to trigger this vulnerability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-14T14:21:22.249Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2024-2039",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2024-2039"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2024-39357",
"datePublished": "2025-01-14T14:21:22.249Z",
"dateReserved": "2024-06-28T18:06:08.518Z",
"dateUpdated": "2025-01-14T16:04:01.283Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Mitigation ID: MIT-10
Phases: Operation, Build and Compilation
Strategy: Environment Hardening
Description:
- Use automatic buffer overflow detection mechanisms that are offered by certain compilers or compiler extensions. Examples include: the Microsoft Visual Studio /GS flag, Fedora/Red Hat FORTIFY_SOURCE GCC flag, StackGuard, and ProPolice, which provide various mechanisms including canary-based detection and range/index checking.
- D3-SFCV (Stack Frame Canary Validation) from D3FEND [REF-1334] discusses canary-based detection in detail.
Mitigation
Phase: Architecture and Design
Description:
- Use an abstraction library to abstract away risky APIs. Not a complete solution.
Mitigation
Phase: Implementation
Description:
- Implement and perform bounds checking on input.
Mitigation
Phase: Implementation
Description:
- Do not use dangerous functions such as gets. Use safer, equivalent functions which check for boundary errors.
Mitigation ID: MIT-11
Phases: Operation, Build and Compilation
Strategy: Environment Hardening
Description:
- Run or compile the software using features or extensions that randomly arrange the positions of a program's executable and libraries in memory. Because this makes the addresses unpredictable, it can prevent an attacker from reliably jumping to exploitable code.
- Examples include Address Space Layout Randomization (ASLR) [REF-58] [REF-60] and Position-Independent Executables (PIE) [REF-64]. Imported modules may be similarly realigned if their default memory addresses conflict with other modules, in a process known as "rebasing" (for Windows) and "prelinking" (for Linux) [REF-1332] using randomly generated addresses. ASLR for libraries cannot be used in conjunction with prelink since it would require relocating the libraries at run-time, defeating the whole purpose of prelinking.
- For more information on these techniques see D3-SAOR (Segment Address Offset Randomization) from D3FEND [REF-1335].
No CAPEC attack patterns related to this CWE.