Common Weakness Enumeration
Show details on NVD website
Show details on NVD website
Show details on NVD website
Show details on NVD website
Show details on NVD website
Show details on NVD website
Show details on NVD website
Show details on NVD website
Show details on NVD website
Show details on NVD website
Back to CWE stats page
CWE-121
Stack-based Buffer Overflow
A stack-based buffer overflow condition is a condition where the buffer being overwritten is allocated on the stack (i.e., is a local variable or, rarely, a parameter to a function).
CVE-2024-10661 (GCVE-0-2024-10661)
Vulnerability from cvelistv5 – Published: 2024-11-01 16:00 – Updated: 2024-11-05 15:26
VLAI
Title
Tenda AC15 SetDlnaCfg stack-based overflow
Summary
A vulnerability has been found in Tenda AC15 15.03.05.19 and classified as critical. This vulnerability affects the function SetDlnaCfg of the file /goform/SetDlnaCfg. The manipulation of the argument scanList leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.282676 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.282676 | signaturepermissions-required |
| https://vuldb.com/?submit.434932 | third-party-advisory |
| https://github.com/theRaz0r/iot-mycve/blob/main/t… | exploit |
| https://www.tenda.com.cn/ | product |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | AC15 |
Affected:
15.03.05.19
|
|
| tenda | ac15_firmware |
Affected:
15.03.05.19
cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac15_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.19"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-10661",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-01T19:06:43.033160Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-05T15:26:23.637Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC15",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.19"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "theRaz0r (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Tenda AC15 15.03.05.19 and classified as critical. This vulnerability affects the function SetDlnaCfg of the file /goform/SetDlnaCfg. The manipulation of the argument scanList leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "In Tenda AC15 15.03.05.19 wurde eine kritische Schwachstelle gefunden. Das betrifft die Funktion SetDlnaCfg der Datei /goform/SetDlnaCfg. Durch das Beeinflussen des Arguments scanList mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-01T16:00:13.148Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-282676 | Tenda AC15 SetDlnaCfg stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.282676"
},
{
"name": "VDB-282676 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.282676"
},
{
"name": "Submit #434932 | Tenda AC15 V15.03.05.19 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.434932"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/theRaz0r/iot-mycve/blob/main/tenda_ac15_stackflow_formDLNAserver/tenda_ac15_stackflow_formDLNAserver.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-11-01T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-11-01T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-11-01T10:18:54.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC15 SetDlnaCfg stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-10661",
"datePublished": "2024-11-01T16:00:13.148Z",
"dateReserved": "2024-11-01T09:13:46.982Z",
"dateUpdated": "2024-11-05T15:26:23.637Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-10662 (GCVE-0-2024-10662)
Vulnerability from cvelistv5 – Published: 2024-11-01 16:00 – Updated: 2024-11-05 15:25
VLAI
Title
Tenda AC15 SetOnlineDevName formSetDeviceName stack-based overflow
Summary
A vulnerability was found in Tenda AC15 15.03.05.19 and classified as critical. This issue affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.282677 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.282677 | signaturepermissions-required |
| https://vuldb.com/?submit.434933 | third-party-advisory |
| https://github.com/theRaz0r/iot-mycve/blob/main/t… | exploit |
| https://www.tenda.com.cn/ | product |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | AC15 |
Affected:
15.03.05.19
|
|
| tenda | ac15_firmware |
Affected:
15.03.05.19
cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac15_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.19"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-10662",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-01T19:06:25.331828Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-05T15:25:38.625Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC15",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.19"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "theRaz0r (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC15 15.03.05.19 and classified as critical. This issue affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in Tenda AC15 15.03.05.19 gefunden. Dies betrifft die Funktion formSetDeviceName der Datei /goform/SetOnlineDevName. Durch Beeinflussen des Arguments devName mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-01T16:00:16.399Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-282677 | Tenda AC15 SetOnlineDevName formSetDeviceName stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.282677"
},
{
"name": "VDB-282677 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.282677"
},
{
"name": "Submit #434933 | Tenda AC15 V15.03.05.19 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.434933"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/theRaz0r/iot-mycve/blob/main/tenda_ac15_stackflow_formSetDeviceName/tenda_ac15_stackflow_formSetDeviceName.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-11-01T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-11-01T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-11-01T10:18:55.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC15 SetOnlineDevName formSetDeviceName stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-10662",
"datePublished": "2024-11-01T16:00:16.399Z",
"dateReserved": "2024-11-01T09:13:49.387Z",
"dateUpdated": "2024-11-05T15:25:38.625Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-10698 (GCVE-0-2024-10698)
Vulnerability from cvelistv5 – Published: 2024-11-02 13:31 – Updated: 2024-11-05 15:20
VLAI
Title
Tenda AC6 SetOnlineDevName formSetDeviceName stack-based overflow
Summary
A vulnerability was found in Tenda AC6 15.03.05.19 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.282866 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.282866 | signaturepermissions-required |
| https://vuldb.com/?submit.434935 | third-party-advisory |
| https://github.com/theRaz0r/iot-mycve/blob/main/t… | exploit |
| https://www.tenda.com.cn/ | product |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | AC6 |
Affected:
15.03.05.19
|
|
| tenda | ac6_firmware |
Affected:
15.03.05.19
cpe:2.3:o:tenda:ac6_firmware:15.03.05.19:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac6_firmware:15.03.05.19:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac6_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.19"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-10698",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-05T15:20:09.420551Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-05T15:20:38.088Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC6",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.19"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "theRaz0r (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC6 15.03.05.19 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda AC6 15.03.05.19 gefunden. Sie wurde als kritisch eingestuft. Es geht hierbei um die Funktion formSetDeviceName der Datei /goform/SetOnlineDevName. Dank Manipulation des Arguments devName mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-02T13:31:07.358Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-282866 | Tenda AC6 SetOnlineDevName formSetDeviceName stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.282866"
},
{
"name": "VDB-282866 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.282866"
},
{
"name": "Submit #434935 | Tenda AC6 V15.03.05.19 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.434935"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/theRaz0r/iot-mycve/blob/main/tenda_ac6_stackflow_formSetDeviceName/tenda_ac6_stackflow_formSetDeviceName.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-11-01T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-11-01T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-11-01T18:06:51.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC6 SetOnlineDevName formSetDeviceName stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-10698",
"datePublished": "2024-11-02T13:31:07.358Z",
"dateReserved": "2024-11-01T17:01:44.965Z",
"dateUpdated": "2024-11-05T15:20:38.088Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-10918 (GCVE-0-2024-10918)
Vulnerability from cvelistv5 – Published: 2025-02-27 11:44 – Updated: 2025-11-03 20:36
VLAI
Title
Stack-based Buffer Overflow in libmodbus library
Summary
Stack-based Buffer Overflow vulnerability in libmodbus v3.1.10 allows to overflow the buffer allocated for the Modbus response if the function tries to reply to a Modbus request with an
unexpected length.
Severity
4.8 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-10918",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-27T14:46:41.226453Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-27T14:46:51.404Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T20:36:25.510Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://lists.debian.org/debian-lts-announce/2025/03/msg00010.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"collectionURL": "https://libmodbus.org/",
"defaultStatus": "unaffected",
"modules": [
"modbus"
],
"product": "libmodbus",
"programFiles": [
"modbus.c"
],
"programRoutines": [
{
"name": "modbus_reply"
}
],
"repo": "https://github.com/stephane/libmodbus",
"vendor": "libmodbus",
"versions": [
{
"lessThanOrEqual": "3.1.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Gabriele Quagliarella of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Stack-based Buffer Overflow vulnerability in libmodbus v3.1.10 allows to overflow the buffer allocated for the Modbus response \u003cspan style=\"background-color: var(--wht);\"\u003eif the function tries to reply to a Modbus request with an\nunexpected length\u003c/span\u003e."
}
],
"value": "Stack-based Buffer Overflow vulnerability in libmodbus v3.1.10 allows to overflow the buffer allocated for the Modbus response if the function tries to reply to a Modbus request with an\nunexpected length."
}
],
"impacts": [
{
"capecId": "CAPEC-100",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-100 Overflow Buffers"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-27T11:44:25.170Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-10918"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "To fix this issue, it\u0027s suggested to update libmodbus to v3.1.11"
}
],
"value": "To fix this issue, it\u0027s suggested to update libmodbus to v3.1.11"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Stack-based Buffer Overflow in libmodbus library",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-10918",
"datePublished": "2025-02-27T11:44:25.170Z",
"dateReserved": "2024-11-06T09:29:36.151Z",
"dateUpdated": "2025-11-03T20:36:25.510Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-11047 (GCVE-0-2024-11047)
Vulnerability from cvelistv5 – Published: 2024-11-10 03:31 – Updated: 2024-11-12 15:46
VLAI
Title
D-Link DI-8003 upgrade_filter.asp upgrade_filter_asp stack-based overflow
Summary
A vulnerability was found in D-Link DI-8003 16.07.16A1. It has been declared as critical. Affected by this vulnerability is the function upgrade_filter_asp of the file /upgrade_filter.asp. The manipulation of the argument path leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.283633 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.283633 | signaturepermissions-required |
| https://vuldb.com/?submit.434931 | third-party-advisory |
| https://github.com/theRaz0r/iot-mycve/blob/main/D… | exploit |
| https://www.dlink.com/ | product |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| D-Link | DI-8003 |
Affected:
16.07.16A1
|
|
| d-link | di-8003_firmware |
Affected:
16.07.16a1
cpe:2.3:o:d-link:di-8003_firmware:16.07.16a1:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:d-link:di-8003_firmware:16.07.16a1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "di-8003_firmware",
"vendor": "d-link",
"versions": [
{
"status": "affected",
"version": "16.07.16a1"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-11047",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-12T15:44:21.435500Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-12T15:46:48.981Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "DI-8003",
"vendor": "D-Link",
"versions": [
{
"status": "affected",
"version": "16.07.16A1"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "theRaz0r (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in D-Link DI-8003 16.07.16A1. It has been declared as critical. Affected by this vulnerability is the function upgrade_filter_asp of the file /upgrade_filter.asp. The manipulation of the argument path leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "In D-Link DI-8003 16.07.16A1 wurde eine kritische Schwachstelle ausgemacht. Dabei geht es um die Funktion upgrade_filter_asp der Datei /upgrade_filter.asp. Durch das Beeinflussen des Arguments path mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-10T03:31:04.900Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-283633 | D-Link DI-8003 upgrade_filter.asp upgrade_filter_asp stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.283633"
},
{
"name": "VDB-283633 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.283633"
},
{
"name": "Submit #434931 | Dlink DI8003 16.07.16A1 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.434931"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/theRaz0r/iot-mycve/blob/main/Dlink_DI8003_stackoverflow/Dlink_DI8003_stackoverflow.md"
},
{
"tags": [
"product"
],
"url": "https://www.dlink.com/"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-11-09T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-11-09T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-11-09T09:13:43.000Z",
"value": "VulDB entry last update"
}
],
"title": "D-Link DI-8003 upgrade_filter.asp upgrade_filter_asp stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-11047",
"datePublished": "2024-11-10T03:31:04.900Z",
"dateReserved": "2024-11-09T08:08:34.041Z",
"dateUpdated": "2024-11-12T15:46:48.981Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-11048 (GCVE-0-2024-11048)
Vulnerability from cvelistv5 – Published: 2024-11-10 04:00 – Updated: 2024-11-12 15:46
VLAI
Title
D-Link DI-8003 dbsrv.asp dbsrv_asp stack-based overflow
Summary
A vulnerability was found in D-Link DI-8003 16.07.16A1. It has been rated as critical. Affected by this issue is the function dbsrv_asp of the file /dbsrv.asp. The manipulation of the argument str leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.283634 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.283634 | signaturepermissions-required |
| https://vuldb.com/?submit.434936 | third-party-advisory |
| https://github.com/theRaz0r/iot-mycve/blob/main/D… | exploit |
| https://www.dlink.com/ | product |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| D-Link | DI-8003 |
Affected:
16.07.16A1
|
|
| d-link | di-8003_firmware |
Affected:
16.07.16a1
cpe:2.3:o:d-link:di-8003_firmware:16.07.16a1:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:d-link:di-8003_firmware:16.07.16a1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "di-8003_firmware",
"vendor": "d-link",
"versions": [
{
"status": "affected",
"version": "16.07.16a1"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-11048",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-12T15:44:15.502899Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-12T15:46:02.785Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "DI-8003",
"vendor": "D-Link",
"versions": [
{
"status": "affected",
"version": "16.07.16A1"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "theRaz0r (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in D-Link DI-8003 16.07.16A1. It has been rated as critical. Affected by this issue is the function dbsrv_asp of the file /dbsrv.asp. The manipulation of the argument str leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in D-Link DI-8003 16.07.16A1 ausgemacht. Hierbei geht es um die Funktion dbsrv_asp der Datei /dbsrv.asp. Durch Beeinflussen des Arguments str mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-10T04:00:10.367Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-283634 | D-Link DI-8003 dbsrv.asp dbsrv_asp stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.283634"
},
{
"name": "VDB-283634 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.283634"
},
{
"name": "Submit #434936 | D-Link DI8003 16.07.16A1 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.434936"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/theRaz0r/iot-mycve/blob/main/Dlink_DI8003_stackoverflow/Dlink-DI8003-stackoverflow-dbsrv.md"
},
{
"tags": [
"product"
],
"url": "https://www.dlink.com/"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-11-09T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-11-09T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-11-09T09:13:45.000Z",
"value": "VulDB entry last update"
}
],
"title": "D-Link DI-8003 dbsrv.asp dbsrv_asp stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-11048",
"datePublished": "2024-11-10T04:00:10.367Z",
"dateReserved": "2024-11-09T08:08:36.541Z",
"dateUpdated": "2024-11-12T15:46:02.785Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-11056 (GCVE-0-2024-11056)
Vulnerability from cvelistv5 – Published: 2024-11-10 16:31 – Updated: 2024-11-12 20:11
VLAI
Title
Tenda AC10 WifiExtraSet FUN_0046AC38 stack-based overflow
Summary
A vulnerability, which was classified as critical, was found in Tenda AC10 16.03.10.13. Affected is the function FUN_0046AC38 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.283800 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.283800 | signaturepermissions-required |
| https://vuldb.com/?submit.439358 | third-party-advisory |
| https://tasty-foxtrot-3a8.notion.site/Tenda-AC10v… | exploit |
| https://www.tenda.com.cn/ | product |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | AC10 |
Affected:
16.03.10.13
|
|
| tenda | ac10_firmware |
Affected:
16.03.10.13
cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "16.03.10.13"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-11056",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-12T16:07:11.156602Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-12T20:11:15.388Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC10",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "16.03.10.13"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "hand_king (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, was found in Tenda AC10 16.03.10.13. Affected is the function FUN_0046AC38 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Es wurde eine Schwachstelle in Tenda AC10 16.03.10.13 gefunden. Sie wurde als kritisch eingestuft. Es betrifft die Funktion FUN_0046AC38 der Datei /goform/WifiExtraSet. Dank der Manipulation des Arguments wpapsk_crypto mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-10T16:31:06.581Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-283800 | Tenda AC10 WifiExtraSet FUN_0046AC38 stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.283800"
},
{
"name": "VDB-283800 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.283800"
},
{
"name": "Submit #439358 | Tenda AC10v4 V16.03.10.13 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.439358"
},
{
"tags": [
"exploit"
],
"url": "https://tasty-foxtrot-3a8.notion.site/Tenda-AC10v4-stack-overflow-1380448e619580409bb1e1ac85f45570"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-11-09T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-11-09T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-11-09T21:19:49.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC10 WifiExtraSet FUN_0046AC38 stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-11056",
"datePublished": "2024-11-10T16:31:06.581Z",
"dateReserved": "2024-11-09T20:14:34.790Z",
"dateUpdated": "2024-11-12T20:11:15.388Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-11061 (GCVE-0-2024-11061)
Vulnerability from cvelistv5 – Published: 2024-11-11 00:31 – Updated: 2024-11-12 18:27
VLAI
Title
Tenda AC10 fast_setting_wifi_set FUN_0044db3c stack-based overflow
Summary
A vulnerability classified as critical was found in Tenda AC10 16.03.10.13. Affected by this vulnerability is the function FUN_0044db3c of the file /goform/fast_setting_wifi_set. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.283807 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.283807 | signaturepermissions-required |
| https://vuldb.com/?submit.440825 | third-party-advisory |
| https://tasty-foxtrot-3a8.notion.site/Tenda-AC10v… | exploit |
| https://www.tenda.com.cn/ | product |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | AC10 |
Affected:
16.03.10.13
|
|
| tenda | ac10_firmware |
Affected:
16.03.10.13
cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "16.03.10.13"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-11061",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-12T16:17:31.059883Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-12T18:27:42.336Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC10",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "16.03.10.13"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "hand_king (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as critical was found in Tenda AC10 16.03.10.13. Affected by this vulnerability is the function FUN_0044db3c of the file /goform/fast_setting_wifi_set. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "In Tenda AC10 16.03.10.13 wurde eine kritische Schwachstelle entdeckt. Betroffen ist die Funktion FUN_0044db3c der Datei /goform/fast_setting_wifi_set. Durch das Manipulieren des Arguments timeZone mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-11T00:31:07.099Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-283807 | Tenda AC10 fast_setting_wifi_set FUN_0044db3c stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.283807"
},
{
"name": "VDB-283807 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.283807"
},
{
"name": "Submit #440825 | Tenda AC10v4 V16.03.10.13 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.440825"
},
{
"tags": [
"exploit"
],
"url": "https://tasty-foxtrot-3a8.notion.site/Tenda-AC10v4-FUN_0044db3c-stack-overflow-13a0448e619580ae96fee2899545e159"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-11-10T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-11-10T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-11-10T09:50:30.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC10 fast_setting_wifi_set FUN_0044db3c stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-11061",
"datePublished": "2024-11-11T00:31:07.099Z",
"dateReserved": "2024-11-10T08:45:18.006Z",
"dateUpdated": "2024-11-12T18:27:42.336Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-11237 (GCVE-0-2024-11237)
Vulnerability from cvelistv5 – Published: 2024-11-15 12:00 – Updated: 2024-11-15 20:42
VLAI
Title
TP-Link VN020 F3v(T) DHCP DISCOVER Packet Parser TP-Thumper stack-based overflow
Summary
A vulnerability, which was classified as critical, has been found in TP-Link VN020 F3v(T) TT_V6.2.1021. Affected by this issue is some unknown functionality of the component DHCP DISCOVER Packet Parser. The manipulation of the argument hostname leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
Severity
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.284672 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.284672 | signaturepermissions-required |
| https://vuldb.com/?submit.438408 | third-party-advisory |
| https://github.com/Zephkek/TP-Thumper | related |
| https://github.com/Zephkek/TP-Thumper/blob/main/poc.c | exploit |
| https://www.tp-link.com/ | product |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| TP-Link | VN020 F3v(T) |
Affected:
TT_V6.2.1021
|
|
| tp-link | vn020_f3v_firmware |
Affected:
tt_v6.2.1021
cpe:2.3:o:tp-link:vn020_f3v_firmware:tt_v6.2.1021:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tp-link:vn020_f3v_firmware:tt_v6.2.1021:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "vn020_f3v_firmware",
"vendor": "tp-link",
"versions": [
{
"status": "affected",
"version": "tt_v6.2.1021"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-11237",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-15T20:29:12.783100Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-15T20:42:20.206Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"DHCP DISCOVER Packet Parser"
],
"product": "VN020 F3v(T)",
"vendor": "TP-Link",
"versions": [
{
"status": "affected",
"version": "TT_V6.2.1021"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Mohamed Maatallah (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, has been found in TP-Link VN020 F3v(T) TT_V6.2.1021. Affected by this issue is some unknown functionality of the component DHCP DISCOVER Packet Parser. The manipulation of the argument hostname leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in TP-Link VN020 F3v(T) TT_V6.2.1021 entdeckt. Dies betrifft einen unbekannten Teil der Komponente DHCP DISCOVER Packet Parser. Durch die Manipulation des Arguments hostname mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 7.8,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-15T12:00:15.886Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-284672 | TP-Link VN020 F3v(T) DHCP DISCOVER Packet Parser TP-Thumper stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.284672"
},
{
"name": "VDB-284672 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.284672"
},
{
"name": "Submit #438408 | TP-Link VN020 F3v(T) ISP Routers Hardware Version: 1.0 / Firmware Version: TT_V6.2.1021 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.438408"
},
{
"tags": [
"related"
],
"url": "https://github.com/Zephkek/TP-Thumper"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Zephkek/TP-Thumper/blob/main/poc.c"
},
{
"tags": [
"product"
],
"url": "https://www.tp-link.com/"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-11-15T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-11-15T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-11-15T08:09:30.000Z",
"value": "VulDB entry last update"
}
],
"title": "TP-Link VN020 F3v(T) DHCP DISCOVER Packet Parser TP-Thumper stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-11237",
"datePublished": "2024-11-15T12:00:15.886Z",
"dateReserved": "2024-11-15T07:04:26.277Z",
"dateUpdated": "2024-11-15T20:42:20.206Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-11248 (GCVE-0-2024-11248)
Vulnerability from cvelistv5 – Published: 2024-11-15 17:00 – Updated: 2024-11-15 19:30
VLAI
Title
Tenda AC10 SetSysAutoRebbotCfg formSetRebootTimer stack-based overflow
Summary
A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.284684 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.284684 | signaturepermissions-required |
| https://vuldb.com/?submit.443204 | third-party-advisory |
| https://tasty-foxtrot-3a8.notion.site/Tenda-AC10v… | exploit |
| https://www.tenda.com.cn/ | product |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | AC10 |
Affected:
16.03.10.13
|
|
| tenda | ac10_firmware |
Affected:
16.03.10.13
cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "16.03.10.13"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-11248",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-15T19:29:37.983327Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-15T19:30:31.322Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC10",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "16.03.10.13"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "hand_king (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda AC10 16.03.10.13 gefunden. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion formSetRebootTimer der Datei /goform/SetSysAutoRebbotCfg. Durch Manipulation des Arguments rebootTime mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-15T17:00:12.864Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-284684 | Tenda AC10 SetSysAutoRebbotCfg formSetRebootTimer stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.284684"
},
{
"name": "VDB-284684 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.284684"
},
{
"name": "Submit #443204 | Tenda AC10v4 V16.03.10.13 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.443204"
},
{
"tags": [
"exploit"
],
"url": "https://tasty-foxtrot-3a8.notion.site/Tenda-AC10v4-formSetRebootTimer-stack-overflow-13d0448e619580bf8ab1df7cfb6c018b"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-11-15T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-11-15T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-11-15T08:40:15.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC10 SetSysAutoRebbotCfg formSetRebootTimer stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-11248",
"datePublished": "2024-11-15T17:00:12.864Z",
"dateReserved": "2024-11-15T07:35:05.406Z",
"dateUpdated": "2024-11-15T19:30:31.322Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Mitigation ID: MIT-10
Phases: Operation, Build and Compilation
Strategy: Environment Hardening
Description:
- Use automatic buffer overflow detection mechanisms that are offered by certain compilers or compiler extensions. Examples include: the Microsoft Visual Studio /GS flag, Fedora/Red Hat FORTIFY_SOURCE GCC flag, StackGuard, and ProPolice, which provide various mechanisms including canary-based detection and range/index checking.
- D3-SFCV (Stack Frame Canary Validation) from D3FEND [REF-1334] discusses canary-based detection in detail.
Mitigation
Phase: Architecture and Design
Description:
- Use an abstraction library to abstract away risky APIs. Not a complete solution.
Mitigation
Phase: Implementation
Description:
- Implement and perform bounds checking on input.
Mitigation
Phase: Implementation
Description:
- Do not use dangerous functions such as gets. Use safer, equivalent functions which check for boundary errors.
Mitigation ID: MIT-11
Phases: Operation, Build and Compilation
Strategy: Environment Hardening
Description:
- Run or compile the software using features or extensions that randomly arrange the positions of a program's executable and libraries in memory. Because this makes the addresses unpredictable, it can prevent an attacker from reliably jumping to exploitable code.
- Examples include Address Space Layout Randomization (ASLR) [REF-58] [REF-60] and Position-Independent Executables (PIE) [REF-64]. Imported modules may be similarly realigned if their default memory addresses conflict with other modules, in a process known as "rebasing" (for Windows) and "prelinking" (for Linux) [REF-1332] using randomly generated addresses. ASLR for libraries cannot be used in conjunction with prelink since it would require relocating the libraries at run-time, defeating the whole purpose of prelinking.
- For more information on these techniques see D3-SAOR (Segment Address Offset Randomization) from D3FEND [REF-1335].
No CAPEC attack patterns related to this CWE.