Common Weakness Enumeration

CWE-489

Allowed

Active Debug Code

Abstraction: Base · Status: Draft

The product is released with debugging code still enabled or active.

141 vulnerabilities reference this CWE, most recent first.

CVE-2025-4106 (GCVE-0-2025-4106)

Vulnerability from cvelistv5 – Published: 2025-10-24 21:32 – Updated: 2026-02-26 16:57
VLAI
Title
WatchGuard Firebox leftover debug code vulnerability
Summary
An authenticated admin user with access to both the management WebUI and command line interface on a Firebox can enable a diagnostic debug shell by uploading a platform and version-specific diagnostic package and executing a leftover diagnostic command. This issue affects Fireware OS: from 12.0 before 12.11.2.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
Impacted products
Vendor Product Version
WatchGuard Fireware OS Affected: 12.0 , < 12.11.2 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-4106",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-28T03:56:00.722896Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-26T16:57:06.433Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Fireware OS",
          "vendor": "WatchGuard",
          "versions": [
            {
              "lessThan": "12.11.2",
              "status": "affected",
              "version": "12.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003eAn authenticated admin user with access to both the management WebUI and command line interface on a Firebox can enable a diagnostic debug shell by uploading a platform and version-specific diagnostic package and executing a leftover diagnostic command.\u003c/div\u003e\u003c/div\u003e\u003cp\u003eThis issue affects Fireware OS: from 12.0 before 12.11.2.\u003c/p\u003e"
            }
          ],
          "value": "An authenticated admin user with access to both the management WebUI and command line interface on a Firebox can enable a diagnostic debug shell by uploading a platform and version-specific diagnostic package and executing a leftover diagnostic command.\n\n\n\nThis issue affects Fireware OS: from 12.0 before 12.11.2."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-121",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-121 Exploit Non-Production Interfaces"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 8.9,
            "baseSeverity": "HIGH",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-489",
              "description": "CWE-489 Active Debug Code",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-24T21:32:30.165Z",
        "orgId": "5d1c2695-1a31-4499-88ae-e847036fd7e3",
        "shortName": "WatchGuard"
      },
      "references": [
        {
          "url": "https://www.watchguard.com/wgrd-psirt/advisory/wgsa-2025-00010"
        }
      ],
      "source": {
        "advisory": "WGSA-2025-00010",
        "defect": [
          "FBX-29549"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "WatchGuard Firebox leftover debug code vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5d1c2695-1a31-4499-88ae-e847036fd7e3",
    "assignerShortName": "WatchGuard",
    "cveId": "CVE-2025-4106",
    "datePublished": "2025-10-24T21:32:30.165Z",
    "dateReserved": "2025-04-30T00:34:47.769Z",
    "dateUpdated": "2026-02-26T16:57:06.433Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-2919 (GCVE-0-2025-2919)

Vulnerability from cvelistv5 – Published: 2025-03-28 17:31 – Updated: 2025-03-28 17:42
VLAI
Title
Netis WF-2404 UART hardware allows activation of test or debug logic at runtime
Summary
A vulnerability was found in Netis WF-2404 1.1.124EN. It has been declared as critical. This vulnerability affects unknown code of the component UART. The manipulation leads to hardware allows activation of test or debug logic at runtime. It is possible to launch the attack on the physical device. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-1313 - Hardware Allows Activation of Test or Debug Logic at Runtime
  • CWE-489 - Active Debug Code
Assigner
References
Impacted products
Vendor Product Version
Netis WF-2404 Affected: 1.1.124EN
Create a notification for this product.
Credits
scoozi (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-2919",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-28T17:42:22.165899Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-28T17:42:25.648Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://scoozi.substack.com/p/hacking-a-netis-wf-2404-router-with"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "UART"
          ],
          "product": "WF-2404",
          "vendor": "Netis",
          "versions": [
            {
              "status": "affected",
              "version": "1.1.124EN"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "scoozi (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Netis WF-2404 1.1.124EN. It has been declared as critical. This vulnerability affects unknown code of the component UART. The manipulation leads to hardware allows activation of test or debug logic at runtime. It is possible to launch the attack on the physical device. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Netis WF-2404 1.1.124EN wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Hierbei betrifft es unbekannten Programmcode der Komponente UART. Durch Beeinflussen mit unbekannten Daten kann eine hardware allows activation of test or debug logic at runtime-Schwachstelle ausgenutzt werden. Ein Angriff setzt physischen Zugriff auf dem Zielobjekt voraus. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 7.2,
            "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1313",
              "description": "Hardware Allows Activation of Test or Debug Logic at Runtime",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-489",
              "description": "Active Debug Code",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-28T17:31:05.919Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-301894 | Netis WF-2404 UART hardware allows activation of test or debug logic at runtime",
          "tags": [
            "vdb-entry"
          ],
          "url": "https://vuldb.com/?id.301894"
        },
        {
          "name": "VDB-301894 | CTI Indicators (IOB, IOC)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.301894"
        },
        {
          "name": "Submit #521036 | Netis WF-2404 Firmware Version: APR-R4A4-V1.1.124EN-Netis(WF-2404),2010.12.14 16:18. Hardware Allows Activation of Test or Debug Logic at Runtime",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.521036"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://scoozi.substack.com/p/hacking-a-netis-wf-2404-router-with"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-03-28T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-03-28T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-03-28T12:53:38.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Netis WF-2404 UART hardware allows activation of test or debug logic at runtime"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-2919",
    "datePublished": "2025-03-28T17:31:05.919Z",
    "dateReserved": "2025-03-28T11:48:25.491Z",
    "dateUpdated": "2025-03-28T17:42:25.648Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-2486 (GCVE-0-2025-2486)

Vulnerability from cvelistv5 – Published: 2025-11-26 17:33 – Updated: 2025-11-26 18:25
VLAI
Title
UEFI Shell accessible in AAVMF with Secure Boot enabled on Ubuntu
Summary
The Ubuntu edk2 UEFI firmware packages accidentally allowed the UEFI Shell to be accessed in Secure Boot environments, possibly allowing bypass of Secure Boot constraints. Versions 2024.05-2ubuntu0.3 and 2024.02-2ubuntu0.3 disable the Shell. Some previous versions inserted a secure-boot-based decision to continue running inside the Shell itself, which is believed to be sufficient to enforce Secure Boot restrictions. This is an additional repair on top of the incomplete fix for CVE-2023-48733.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
Assigner
Impacted products
Vendor Product Version
Ubuntu edk2 Affected: 2024.05 , < 2024.05-2ubuntu0.3 (dpkg)
Affected: 2024.02 , < 2024.02-2ubuntu0.3 (dpkg)
Create a notification for this product.
Credits
Dann Frazier
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-2486",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-26T18:25:19.164474Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-26T18:25:29.426Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "AAVMF UEFI Shell"
          ],
          "platforms": [
            "aarch64"
          ],
          "product": "edk2",
          "vendor": "Ubuntu",
          "versions": [
            {
              "lessThan": "2024.05-2ubuntu0.3",
              "status": "affected",
              "version": "2024.05",
              "versionType": "dpkg"
            },
            {
              "lessThan": "2024.02-2ubuntu0.3",
              "status": "affected",
              "version": "2024.02",
              "versionType": "dpkg"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dann Frazier"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The Ubuntu edk2 UEFI firmware packages accidentally allowed the UEFI Shell to be accessed in Secure Boot environments, possibly allowing bypass of Secure Boot constraints. Versions 2024.05-2ubuntu0.3 and 2024.02-2ubuntu0.3 disable the Shell. Some previous versions inserted a secure-boot-based decision to continue running inside the Shell itself, which is believed to be sufficient to enforce Secure Boot restrictions. This is an additional repair on top of the incomplete fix for CVE-2023-48733."
            }
          ],
          "value": "The Ubuntu edk2 UEFI firmware packages accidentally allowed the UEFI Shell to be accessed in Secure Boot environments, possibly allowing bypass of Secure Boot constraints. Versions 2024.05-2ubuntu0.3 and 2024.02-2ubuntu0.3 disable the Shell. Some previous versions inserted a secure-boot-based decision to continue running inside the Shell itself, which is believed to be sufficient to enforce Secure Boot restrictions. This is an additional repair on top of the incomplete fix for CVE-2023-48733."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-554",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-554 Functionality Bypass"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 3.7,
            "baseSeverity": "LOW",
            "exploitMaturity": "UNREPORTED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "ACTIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:A/VC:N/VI:H/VA:N/SC:H/SI:H/SA:H/E:U",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-489",
              "description": "CWE-489: Active Debug Code",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-26T17:33:17.506Z",
        "orgId": "cc1ad9ee-3454-478d-9317-d3e869d708bc",
        "shortName": "canonical"
      },
      "references": [
        {
          "url": "https://bugs.launchpad.net/ubuntu/+source/edk2/+bug/2101797"
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "UEFI Shell accessible in AAVMF with Secure Boot enabled on Ubuntu"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cc1ad9ee-3454-478d-9317-d3e869d708bc",
    "assignerShortName": "canonical",
    "cveId": "CVE-2025-2486",
    "datePublished": "2025-11-26T17:33:17.506Z",
    "dateReserved": "2025-03-18T01:16:20.240Z",
    "dateUpdated": "2025-11-26T18:25:29.426Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-1479 (GCVE-0-2025-1479)

Vulnerability from cvelistv5 – Published: 2025-05-30 19:13 – Updated: 2026-02-26 18:27
VLAI
Summary
An open debug interface was reported in the Legion Space software included on certain Legion devices that could allow a local attacker to execute arbitrary code.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
Impacted products
Credits
Lenovo thanks Aobo Wang(@M4x_1997) of Chaitin Security Research Lab for reporting this issue.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-1479",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-03T03:55:12.265203Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-26T18:27:50.445Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Legion Space for Legion Go",
          "vendor": "Lenovo",
          "versions": [
            {
              "lessThan": "1.2.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Legion Space for Legion PC",
          "vendor": "Lenovo",
          "versions": [
            {
              "lessThan": "1.4.11.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:lenovo:legion_space_for_legion_go:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "1.2.3.8",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:lenovo:legion_space_for_legion_pc:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "1.4.11.4",
                  "vulnerable": true
                }
              ],
              "operator": "OR"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Lenovo thanks Aobo Wang(@M4x_1997) of Chaitin Security Research Lab for reporting this issue."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn open debug interface was reported in the Legion Space software included on certain Legion devices that could allow a local attacker to execute arbitrary code.\u003c/span\u003e"
            }
          ],
          "value": "An open debug interface was reported in the Legion Space software included on certain Legion devices that could allow a local attacker to execute arbitrary code."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 4.8,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "LOW",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-489",
              "description": "CWE-489: Active Debug Code",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-05-30T19:13:47.411Z",
        "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "shortName": "lenovo"
      },
      "references": [
        {
          "url": "https://support.lenovo.com/us/en/product_security/LEN-186929"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUpdate Legion Space for Legion Go devices to version 1.2.3.8 (or newer).\u003c/span\u003e\u003cbr\u003e"
            }
          ],
          "value": "Update Legion Space for Legion Go devices to version 1.2.3.8 (or newer)."
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUpdate Legion Space for Legion PC devices to version 1.4.11.4 (or newer).\u003c/span\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Update Legion Space for Legion PC devices to version 1.4.11.4 (or newer)."
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
    "assignerShortName": "lenovo",
    "cveId": "CVE-2025-1479",
    "datePublished": "2025-05-30T19:13:47.411Z",
    "dateReserved": "2025-02-19T19:11:52.797Z",
    "dateUpdated": "2026-02-26T18:27:50.445Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2024-53648 (GCVE-0-2024-53648)

Vulnerability from cvelistv5 – Published: 2025-02-11 10:28 – Updated: 2025-11-11 20:20
VLAI
Summary
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions < V9.90), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions < V9.90), SIPROTEC 5 6MD89 (CP300) (All versions < V9.90), SIPROTEC 5 6MU85 (CP300) (All versions < V9.90), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions < V10.0), SIPROTEC 5 7SA82 (CP100) (All versions < V8.90), SIPROTEC 5 7SA82 (CP150) (All versions < V9.90), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions < V9.90), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions < V9.90), SIPROTEC 5 7SD82 (CP100) (All versions < V8.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.90), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions < V9.90), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions < V9.90), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions < V9.90), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions < V9.90), SIPROTEC 5 7SK82 (CP100) (All versions < V8.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.90), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions < V9.90), SIPROTEC 5 7SL82 (CP100) (All versions < V8.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.90), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions < V9.90), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions < V9.90), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions < V9.90), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7SX82 (CP150) (All versions < V9.90), SIPROTEC 5 7SX85 (CP300) (All versions < V9.90), SIPROTEC 5 7SY82 (CP150) (All versions < V9.90), SIPROTEC 5 7UM85 (CP300) (All versions < V9.90), SIPROTEC 5 7UT82 (CP100) (All versions < V8.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.90), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions < V9.90), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions < V9.90), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions < V9.90), SIPROTEC 5 7VE85 (CP300) (All versions < V9.90), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions < V9.90), SIPROTEC 5 7VU85 (CP300) (All versions < V9.90), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.90). Affected devices do not properly limit access to a development shell accessible over a physical interface. This could allow an unauthenticated attacker with physical access to the device to execute arbitrary commands on the device.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
Impacted products
Vendor Product Version
Siemens SIPROTEC 5 6MD84 (CP300) Affected: 0 , < V9.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 6MD85 (CP200) Affected: 0 , < * (custom)
Create a notification for this product.
Siemens SIPROTEC 5 6MD85 (CP300) Affected: 0 , < V9.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 6MD86 (CP200) Affected: 0 , < * (custom)
Create a notification for this product.
Siemens SIPROTEC 5 6MD86 (CP300) Affected: 0 , < V9.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 6MD89 (CP300) Affected: 0 , < V9.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 6MU85 (CP300) Affected: 0 , < V9.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7KE85 (CP200) Affected: 0 , < * (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7KE85 (CP300) Affected: 0 , < V10.0 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7SA82 (CP100) Affected: 0 , < V8.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7SA82 (CP150) Affected: 0 , < V9.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7SA86 (CP200) Affected: 0 , < * (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7SA86 (CP300) Affected: 0 , < V9.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7SA87 (CP200) Affected: 0 , < * (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7SA87 (CP300) Affected: 0 , < V9.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7SD82 (CP100) Affected: 0 , < V8.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7SD82 (CP150) Affected: 0 , < V9.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7SD86 (CP200) Affected: 0 , < * (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7SD86 (CP300) Affected: 0 , < V9.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7SD87 (CP200) Affected: 0 , < * (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7SD87 (CP300) Affected: 0 , < V9.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7SJ81 (CP100) Affected: 0 , < V8.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7SJ81 (CP150) Affected: 0 , < V9.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7SJ82 (CP100) Affected: 0 , < V8.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7SJ82 (CP150) Affected: 0 , < V9.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7SJ85 (CP200) Affected: 0 , < * (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7SJ85 (CP300) Affected: 0 , < V9.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7SJ86 (CP200) Affected: 0 , < * (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7SJ86 (CP300) Affected: 0 , < V9.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7SK82 (CP100) Affected: 0 , < V8.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7SK82 (CP150) Affected: 0 , < V9.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7SK85 (CP200) Affected: 0 , < * (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7SK85 (CP300) Affected: 0 , < V9.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7SL82 (CP100) Affected: 0 , < V8.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7SL82 (CP150) Affected: 0 , < V9.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7SL86 (CP200) Affected: 0 , < * (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7SL86 (CP300) Affected: 0 , < V9.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7SL87 (CP200) Affected: 0 , < * (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7SL87 (CP300) Affected: 0 , < V9.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7SS85 (CP200) Affected: 0 , < * (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7SS85 (CP300) Affected: 0 , < V9.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7ST85 (CP200) Affected: 0 , < * (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7ST85 (CP300) Affected: 0 , < V10.0 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7ST86 (CP300) Affected: 0 , < V10.0 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7SX82 (CP150) Affected: 0 , < V9.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7SX85 (CP300) Affected: 0 , < V9.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7SY82 (CP150) Affected: 0 , < V9.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7UM85 (CP300) Affected: 0 , < V9.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7UT82 (CP100) Affected: 0 , < V8.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7UT82 (CP150) Affected: 0 , < V9.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7UT85 (CP200) Affected: 0 , < * (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7UT85 (CP300) Affected: 0 , < V9.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7UT86 (CP200) Affected: 0 , < * (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7UT86 (CP300) Affected: 0 , < V9.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7UT87 (CP200) Affected: 0 , < * (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7UT87 (CP300) Affected: 0 , < V9.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7VE85 (CP300) Affected: 0 , < V9.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7VK87 (CP200) Affected: 0 , < * (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7VK87 (CP300) Affected: 0 , < V9.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 7VU85 (CP300) Affected: 0 , < V9.90 (custom)
Create a notification for this product.
Siemens SIPROTEC 5 Compact 7SX800 (CP050) Affected: 0 , < V9.90 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-53648",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-11T14:35:44.427665Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-11T14:35:58.855Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 6MD84 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 6MD85 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 6MD85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 6MD86 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 6MD86 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 6MD89 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 6MU85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7KE85 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7KE85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SA82 (CP100)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SA82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SA86 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SA86 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SA87 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SA87 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SD82 (CP100)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SD82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SD86 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SD86 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SD87 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SD87 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SJ81 (CP100)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SJ81 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SJ82 (CP100)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SJ82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SJ85 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SJ85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SJ86 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SJ86 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SK82 (CP100)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SK82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SK85 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SK85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SL82 (CP100)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SL82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SL86 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SL86 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SL87 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SL87 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SS85 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SS85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7ST85 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7ST85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7ST86 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SX82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SX85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SY82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UM85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UT82 (CP100)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UT82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UT85 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UT85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UT86 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UT86 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UT87 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UT87 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7VE85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7VK87 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7VK87 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7VU85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 Compact 7SX800 (CP050)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions \u003c V9.90), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions \u003c V9.90), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions \u003c V9.90), SIPROTEC 5 6MD89 (CP300) (All versions \u003c V9.90), SIPROTEC 5 6MU85 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions \u003c V10.0), SIPROTEC 5 7SA82 (CP100) (All versions \u003c V8.90), SIPROTEC 5 7SA82 (CP150) (All versions \u003c V9.90), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7SD82 (CP100) (All versions \u003c V8.90), SIPROTEC 5 7SD82 (CP150) (All versions \u003c V9.90), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7SJ81 (CP100) (All versions \u003c V8.90), SIPROTEC 5 7SJ81 (CP150) (All versions \u003c V9.90), SIPROTEC 5 7SJ82 (CP100) (All versions \u003c V8.90), SIPROTEC 5 7SJ82 (CP150) (All versions \u003c V9.90), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7SK82 (CP100) (All versions \u003c V8.90), SIPROTEC 5 7SK82 (CP150) (All versions \u003c V9.90), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7SL82 (CP100) (All versions \u003c V8.90), SIPROTEC 5 7SL82 (CP150) (All versions \u003c V9.90), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions \u003c V10.0), SIPROTEC 5 7ST86 (CP300) (All versions \u003c V10.0), SIPROTEC 5 7SX82 (CP150) (All versions \u003c V9.90), SIPROTEC 5 7SX85 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7SY82 (CP150) (All versions \u003c V9.90), SIPROTEC 5 7UM85 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7UT82 (CP100) (All versions \u003c V8.90), SIPROTEC 5 7UT82 (CP150) (All versions \u003c V9.90), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7VE85 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7VU85 (CP300) (All versions \u003c V9.90), SIPROTEC 5 Compact 7SX800 (CP050) (All versions \u003c V9.90). Affected devices do not properly limit access to a development shell accessible over a physical interface. This could allow an unauthenticated attacker with physical access to the device to execute arbitrary commands on the device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-489",
              "description": "CWE-489: Active Debug Code",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-11T20:20:22.924Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-687955.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-53648",
    "datePublished": "2025-02-11T10:28:52.039Z",
    "dateReserved": "2024-11-21T13:26:39.692Z",
    "dateUpdated": "2025-11-11T20:20:22.924Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2024-46873 (GCVE-0-2024-46873)

Vulnerability from cvelistv5 – Published: 2024-12-23 00:17 – Updated: 2024-12-24 00:39
VLAI
Summary
Multiple SHARP routers leave the hidden debug function enabled. An arbitrary OS command may be executed with the root privilege by a remote unauthenticated attacker.
SSVC
Exploitation: none Automatable: yes Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-46873",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-12-24T00:35:52.238750Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-12-24T00:39:44.951Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "home 5G HR02",
          "vendor": "Sharp Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "S5.82.00 and earlier"
            }
          ]
        },
        {
          "product": "Wi-Fi STATION SH-52B",
          "vendor": "Sharp Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "S3.87.11 and earlier"
            }
          ]
        },
        {
          "product": "Wi-Fi STATION SH-54C",
          "vendor": "Sharp Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "S6.60.00 and earlier"
            }
          ]
        },
        {
          "product": "Wi-Fi STATION SH-05L",
          "vendor": "Sharp Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "01.00.C0 and earlier"
            }
          ]
        },
        {
          "product": "PocketWifi 809SH",
          "vendor": "Sharp Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "01.00.B9 and earlier"
            }
          ]
        },
        {
          "product": "Speed Wi-Fi NEXT W07",
          "vendor": "Sharp Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "02.00.48 and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Multiple SHARP routers leave the hidden debug function enabled. An arbitrary OS command may be executed with the root privilege by a remote unauthenticated attacker."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en-US",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-489",
              "description": "Active debug code",
              "lang": "en-US",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-12-23T00:17:59.216Z",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "url": "https://k-tai.sharp.co.jp/support/info/info083.html"
        },
        {
          "url": "https://jvn.jp/en/jp/JVN61635834/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2024-46873",
    "datePublished": "2024-12-23T00:17:59.216Z",
    "dateReserved": "2024-12-02T06:03:30.029Z",
    "dateUpdated": "2024-12-24T00:39:44.951Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-41999 (GCVE-0-2024-41999)

Vulnerability from cvelistv5 – Published: 2024-09-30 07:50 – Updated: 2024-09-30 16:45
VLAI
Summary
Smart-tab Android app installed April 2023 or earlier contains an active debug code vulnerability. If this vulnerability is exploited, an attacker with physical access to the device may exploit the debug function to gain access to the OS functions, escalate the privilege, change the device's settings, or spoof devices in other rooms.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
Impacted products
Vendor Product Version
TECHNO SUPPORT COMPANY Smart-tab Android app Affected: installed April 2023 or earlier
Create a notification for this product.
android_app smart_tab Affected: 0 , < * (custom)
    cpe:2.3:a:android_app:smart_tab:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:android_app:smart_tab:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "smart_tab",
            "vendor": "android_app",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "PHYSICAL",
              "availabilityImpact": "HIGH",
              "baseScore": 6.8,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-41999",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-30T16:41:52.476692Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-30T16:45:01.184Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Smart-tab Android app",
          "vendor": "TECHNO SUPPORT COMPANY",
          "versions": [
            {
              "status": "affected",
              "version": "installed April 2023 or earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Smart-tab Android app installed April 2023 or earlier contains an active debug code vulnerability. If this vulnerability is exploited, an attacker with physical access to the device may exploit the debug function to gain access to the OS functions, escalate the privilege, change the device\u0027s settings, or spoof devices in other rooms."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en-US",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-489",
              "description": "Active debug code",
              "lang": "en-US",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-30T07:50:34.536Z",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "url": "https://tsc-soft.co.jp/smart-tab/"
        },
        {
          "url": "https://jvn.jp/en/jp/JVN42445661/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2024-41999",
    "datePublished": "2024-09-30T07:50:34.536Z",
    "dateReserved": "2024-09-18T23:09:30.952Z",
    "dateUpdated": "2024-09-30T16:45:01.184Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-32047 (GCVE-0-2024-32047)

Vulnerability from cvelistv5 – Published: 2024-05-15 19:36 – Updated: 2024-08-02 02:06
VLAI
Title
CyberPower PowerPanel business Active Debug Code
Summary
Hard-coded credentials for the CyberPower PowerPanel test server can be found in the production code. This might result in an attacker gaining access to the testing or production server.
SSVC
Exploitation: none Automatable: yes Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
Impacted products
Vendor Product Version
CyberPower PowerPanel business Affected: 0 , < 4.9.0 (custom)
Create a notification for this product.
cyberpower powerpanel_business Affected: 0 , < 4.9.0 (custom)
    cpe:2.3:a:cyberpower:powerpanel_business:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
Amir Preminger and Noam Moshe of Claroty Team82 Research reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:cyberpower:powerpanel_business:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "powerpanel_business",
            "vendor": "cyberpower",
            "versions": [
              {
                "lessThan": "4.9.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-32047",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-16T18:13:39.475129Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:50:55.367Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T02:06:43.550Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-123-01"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cyberpower.com/global/en/product/sku/powerpanel_business_for_windows#downloads"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerPanel business",
          "vendor": "CyberPower",
          "versions": [
            {
              "lessThan": "4.9.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Amir Preminger and Noam Moshe of Claroty Team82 Research reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Hard-coded credentials for the \nCyberPower PowerPanel test server can be found in the \nproduction code. This might result in an attacker gaining access to the \ntesting or production server.\n\n\u003cbr\u003e"
            }
          ],
          "value": "Hard-coded credentials for the \nCyberPower PowerPanel test server can be found in the \nproduction code. This might result in an attacker gaining access to the \ntesting or production server."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-489",
              "description": "CWE-489",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-15T19:36:41.936Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-123-01"
        },
        {
          "url": "https://www.cyberpower.com/global/en/product/sku/powerpanel_business_for_windows#downloads"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\u003cp\u003eCyberPower has released a new version (v4.10.1 or later version) of PowerPanel business that fixes these vulnerabilities.\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.cyberpower.com/global/en/product/sku/powerpanel_business_for_windows#downloads\"\u003ehttps://www.cyberpower.com/global/en/product/sku/powerpanel_business_for_windows#downloads\u003c/a\u003e\u003cbr\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "CyberPower has released a new version (v4.10.1 or later version) of PowerPanel business that fixes these vulnerabilities.\n\n\n https://www.cyberpower.com/global/en/product/sku/powerpanel_business_for_windows#downloads"
        }
      ],
      "source": {
        "advisory": "ICSA-24-123-01",
        "discovery": "EXTERNAL"
      },
      "title": "CyberPower PowerPanel business Active Debug Code",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2024-32047",
    "datePublished": "2024-05-15T19:36:41.936Z",
    "dateReserved": "2024-04-29T16:47:22.349Z",
    "dateUpdated": "2024-08-02T02:06:43.550Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-30219 (GCVE-0-2024-30219)

Vulnerability from cvelistv5 – Published: 2024-04-15 10:42 – Updated: 2025-08-27 21:02
VLAI
Summary
Active debug code vulnerability exists in PLANEX COMMUNICATIONS wireless LAN routers. If a logged-in user who knows how to use the debug function accesses the device's management page, an unintended operation may be performed. Note that MZK-MF300N is no longer supported, therefore the update for this product is not provided.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
Impacted products
Vendor Product Version
PLANEX COMMUNICATIONS INC. MZK-MF300N Affected: all firmware versions
Create a notification for this product.
PLANEX COMMUNICATIONS INC. MZK-MF300HP2 Affected: firmware versions 1.18 and earlier
Create a notification for this product.
planex mzk-mf300n_firmware Affected: 0 , < * (custom)
    cpe:2.3:o:planex:mzk-mf300n_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:planex:mzk-mf300n_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "mzk-mf300n_firmware",
            "vendor": "planex",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-30219",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-27T02:15:27.805566Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-27T21:02:07.280Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:25:03.416Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/vu/JVNVU91975826/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "MZK-MF300N",
          "vendor": "PLANEX COMMUNICATIONS INC.",
          "versions": [
            {
              "status": "affected",
              "version": "all firmware versions"
            }
          ]
        },
        {
          "product": "MZK-MF300HP2",
          "vendor": "PLANEX COMMUNICATIONS INC.",
          "versions": [
            {
              "status": "affected",
              "version": "firmware versions 1.18 and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Active debug code vulnerability exists in PLANEX COMMUNICATIONS wireless LAN routers. If a logged-in user who knows how to use the debug function accesses the device\u0027s management page, an unintended operation may be performed. Note that MZK-MF300N is no longer supported, therefore the update for this product is not provided."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en-US",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-489",
              "description": "Active debug code",
              "lang": "en-US",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-26T07:21:48.696Z",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "url": "https://jvn.jp/en/vu/JVNVU91975826/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2024-30219",
    "datePublished": "2024-04-15T10:42:30.673Z",
    "dateReserved": "2024-03-26T06:29:22.984Z",
    "dateUpdated": "2025-08-27T21:02:07.280Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-29075 (GCVE-0-2024-29075)

Vulnerability from cvelistv5 – Published: 2024-11-12 05:30 – Updated: 2024-11-12 14:41
VLAI
Summary
Active debug code vulnerability exists in Mesh Wi-Fi router RP562B firmware version v1.0.2 and earlier. If this vulnerability is exploited, a network-adjacent authenticated attacker may obtain or alter the settings of the device .
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
Assigner
References
Impacted products
Vendor Product Version
SoftBank Corp. Mesh Wi-Fi router RP562B Affected: firmware version v1.0.2 and earlier
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-29075",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-12T14:41:08.506744Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-12T14:41:17.749Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Mesh Wi-Fi router RP562B",
          "vendor": "SoftBank Corp.",
          "versions": [
            {
              "status": "affected",
              "version": "firmware version v1.0.2 and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Active debug code vulnerability exists in Mesh Wi-Fi router RP562B firmware version v1.0.2 and earlier. If this vulnerability is exploited, a network-adjacent authenticated attacker may obtain or alter the settings of the device ."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 4.6,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en-US",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-489",
              "description": "Active debug code",
              "lang": "en-US",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-12T05:30:10.952Z",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "url": "https://jvn.jp/en/vu/JVNVU90676195/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2024-29075",
    "datePublished": "2024-11-12T05:30:10.952Z",
    "dateReserved": "2024-10-30T23:12:15.239Z",
    "dateUpdated": "2024-11-12T14:41:17.749Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation
Build and Compilation Distribution

Remove debug code before deploying the application.

CAPEC-121: Exploit Non-Production Interfaces

An adversary exploits a sample, demonstration, test, or debug interface that is unintentionally enabled on a production system, with the goal of gleaning information or leveraging functionality that would otherwise be unavailable.

CAPEC-661: Root/Jailbreak Detection Evasion via Debugging

An adversary inserts a debugger into the program entry point of a mobile application to modify the application binary, with the goal of evading Root/Jailbreak detection. Mobile device users often Root/Jailbreak their devices in order to gain administrative control over the mobile operating system and/or to install third-party mobile applications that are not provided by authorized application stores (e.g. Google Play Store and Apple App Store). Rooting/Jailbreaking a mobile device also provides users with access to system debuggers and disassemblers, which can be leveraged to exploit applications by dumping the application's memory at runtime in order to remove or bypass signature verification methods. This further allows the adversary to evade Root/Jailbreak detection mechanisms, which can result in execution of administrative commands, obtaining confidential data, impersonating legitimate users of the application, and more.