CWE-319
AllowedCleartext Transmission of Sensitive Information
Abstraction: Base · Status: Draft
The product transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors.
1194 vulnerabilities reference this CWE, most recent first.
CVE-2022-46680 (GCVE-0-2022-46680)
Vulnerability from cvelistv5 – Published: 2023-05-22 13:25 – Updated: 2025-01-21 15:05- CWE-319 - Cleartext Transmission of Sensitive Information
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | PowerLogic ION9000 |
Affected:
Prior to 4.0.0
|
|
| Schneider Electric | PowerLogic ION7400 |
Affected:
Prior to 4.0.0
|
|
| Schneider Electric | PowerLogic PM8000 |
Affected:
Prior to 4.0.0
|
|
| Schneider Electric | PowerLogic ION8650 |
Affected:
All Versions
|
|
| Schneider Electric | PowerLogic ION8800 |
Affected:
All Versions
|
|
| Schneider Electric | Legacy ION products |
Affected:
All Versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:39:38.551Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-03.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-46680",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-21T15:05:13.390998Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-21T15:05:49.099Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerLogic ION9000",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Prior to 4.0.0"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PowerLogic ION7400",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Prior to 4.0.0"
}
]
},
{
"defaultStatus": "unaffected",
"product": " PowerLogic PM8000",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Prior to 4.0.0"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PowerLogic ION8650",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PowerLogic ION8800",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Legacy ION products",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
}
],
"datePublic": "2023-05-09T13:18:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nA CWE-319: Cleartext transmission of sensitive information vulnerability exists that could\ncause disclosure of sensitive information, denial of service, or modification of data if an attacker\nis able to intercept network traffic. \n\n"
}
],
"value": "\nA CWE-319: Cleartext transmission of sensitive information vulnerability exists that could\ncause disclosure of sensitive information, denial of service, or modification of data if an attacker\nis able to intercept network traffic. \n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319 Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-05-22T13:25:40.615Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-03.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-46680",
"datePublished": "2023-05-22T13:25:40.615Z",
"dateReserved": "2022-12-06T21:51:38.755Z",
"dateUpdated": "2025-01-21T15:05:49.099Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-45483 (GCVE-0-2022-45483)
Vulnerability from cvelistv5 – Published: 2022-12-02 00:00 – Updated: 2025-04-24 13:55- CWE-319 - Cleartext Transmission of Sensitive Information
| Vendor | Product | Version | |
|---|---|---|---|
| thisAAY | Lazy Mouse |
Affected:
<= 2.0.1
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:17:03.644Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.synopsys.com/blogs/software-security/cyrc-advisory-remote-code-execution-vulnerabilities-mouse-keyboard-apps/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-45483",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-24T13:55:04.423314Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-24T13:55:38.620Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Lazy Mouse",
"vendor": "thisAAY",
"versions": [
{
"status": "affected",
"version": "\u003c= 2.0.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Lazy Mouse allows an attacker (in a man in the middle position between the server and a connected device) to see all data (including keypresses) in cleartext. CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319: Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-12-02T00:00:00.000Z",
"orgId": "8cad7728-009c-4a3d-a95e-ca62e6ff8a0b",
"shortName": "SNPS"
},
"references": [
{
"url": "https://www.synopsys.com/blogs/software-security/cyrc-advisory-remote-code-execution-vulnerabilities-mouse-keyboard-apps/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8cad7728-009c-4a3d-a95e-ca62e6ff8a0b",
"assignerShortName": "SNPS",
"cveId": "CVE-2022-45483",
"datePublished": "2022-12-02T00:00:00.000Z",
"dateReserved": "2022-11-18T00:00:00.000Z",
"dateUpdated": "2025-04-24T13:55:38.620Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-45480 (GCVE-0-2022-45480)
Vulnerability from cvelistv5 – Published: 2022-12-02 00:00 – Updated: 2025-04-24 20:16- CWE-319 - Cleartext Transmission of Sensitive Information
| Vendor | Product | Version | |
|---|---|---|---|
| Telepad | PC Keyboard WiFi & Bluetooth |
Affected:
<= 30
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:17:03.951Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.synopsys.com/blogs/software-security/cyrc-advisory-remote-code-execution-vulnerabilities-mouse-keyboard-apps/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-45480",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-24T20:15:43.986135Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-24T20:16:07.710Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "PC Keyboard WiFi \u0026 Bluetooth",
"vendor": "Telepad",
"versions": [
{
"status": "affected",
"version": "\u003c= 30"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "PC Keyboard WiFi \u0026 Bluetooth allows an attacker (in a man-in-the-middle position between the server and a connected device) to see all data (including keypresses) in cleartext. CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319: Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-12-02T00:00:00.000Z",
"orgId": "8cad7728-009c-4a3d-a95e-ca62e6ff8a0b",
"shortName": "SNPS"
},
"references": [
{
"url": "https://www.synopsys.com/blogs/software-security/cyrc-advisory-remote-code-execution-vulnerabilities-mouse-keyboard-apps/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8cad7728-009c-4a3d-a95e-ca62e6ff8a0b",
"assignerShortName": "SNPS",
"cveId": "CVE-2022-45480",
"datePublished": "2022-12-02T00:00:00.000Z",
"dateReserved": "2022-11-18T00:00:00.000Z",
"dateUpdated": "2025-04-24T20:16:07.710Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-45478 (GCVE-0-2022-45478)
Vulnerability from cvelistv5 – Published: 2022-12-05 00:00 – Updated: 2025-04-23 19:37- CWE-319 - Cleartext Transmission of Sensitive Information
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:17:03.591Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.synopsys.com/blogs/software-security/cyrc-advisory-remote-code-execution-vulnerabilities-mouse-keyboard-apps/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-45478",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-23T19:35:55.227190Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-23T19:37:25.370Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Telepad",
"vendor": "Telepad",
"versions": [
{
"status": "affected",
"version": "\u003c= 1.0.7"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Telepad allows an attacker (in a man-in-the-middle position between the server and a connected device) to see all data (including keypresses) in cleartext. CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319: Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-12-05T00:00:00.000Z",
"orgId": "8cad7728-009c-4a3d-a95e-ca62e6ff8a0b",
"shortName": "SNPS"
},
"references": [
{
"url": "https://www.synopsys.com/blogs/software-security/cyrc-advisory-remote-code-execution-vulnerabilities-mouse-keyboard-apps/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8cad7728-009c-4a3d-a95e-ca62e6ff8a0b",
"assignerShortName": "SNPS",
"cveId": "CVE-2022-45478",
"datePublished": "2022-12-05T00:00:00.000Z",
"dateReserved": "2022-11-18T00:00:00.000Z",
"dateUpdated": "2025-04-23T19:37:25.370Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-43724 (GCVE-0-2022-43724)
Vulnerability from cvelistv5 – Published: 2022-12-13 00:00 – Updated: 2025-04-22 15:15- CWE-319 - Cleartext Transmission of Sensitive Information
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SICAM PAS/PQS |
Affected:
All versions < V7.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:40:06.447Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-849072.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-43724",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-22T15:15:52.623535Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319 Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-22T15:15:56.110Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "SICAM PAS/PQS",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SICAM PAS/PQS (All versions \u003c V7.0). Affected software transmits the database credentials for the inbuilt SQL server in cleartext. In combination with the by default enabled xp_cmdshell feature unauthenticated remote attackers could execute custom OS commands. At the time of assigning the CVE, the affected firmware version of the component has already been superseded by succeeding mainline versions."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319: Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-12-13T00:00:00.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-849072.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-43724",
"datePublished": "2022-12-13T00:00:00.000Z",
"dateReserved": "2022-10-24T00:00:00.000Z",
"dateUpdated": "2025-04-22T15:15:56.110Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-43551 (GCVE-0-2022-43551)
Vulnerability from cvelistv5 – Published: 2022-12-23 00:00 – Updated: 2026-02-13 19:43- CWE-319 - Cleartext Transmission of Sensitive Information (CWE-319)
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | https://github.com/curl/curl |
Affected:
Fixed in curl 7.87.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:32:59.718Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://hackerone.com/reports/1755083"
},
{
"name": "FEDORA-2022-d7ee33d4ad",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/TVWZW5CNSJ7UYAF2BGSYAWAEXDJYUBHA/"
},
{
"tags": [
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20230427-0007/"
},
{
"tags": [
"x_transferred"
],
"url": "https://security.gentoo.org/glsa/202310-12"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-43551",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-15T14:38:16.813663Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-13T19:43:56.236Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "https://github.com/curl/curl",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Fixed in curl 7.87.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability exists in curl \u003c7.87.0 HSTS check that could be bypassed to trick it to keep using HTTP. Using its HSTS support, curl can be instructed to use HTTPS instead of using an insecure clear-text HTTP step even when HTTP is provided in the URL. However, the HSTS mechanism could be bypassed if the host name in the given URL first uses IDN characters that get replaced to ASCII counterparts as part of the IDN conversion. Like using the character UTF-8 U+3002 (IDEOGRAPHIC FULL STOP) instead of the common ASCII full stop (U+002E) `.`. Then in a subsequent request, it does not detect the HSTS state and makes a clear text transfer. Because it would store the info IDN encoded but look for it IDN decoded."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "Cleartext Transmission of Sensitive Information (CWE-319)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-11T10:06:25.590Z",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"url": "https://hackerone.com/reports/1755083"
},
{
"name": "FEDORA-2022-d7ee33d4ad",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/TVWZW5CNSJ7UYAF2BGSYAWAEXDJYUBHA/"
},
{
"url": "https://security.netapp.com/advisory/ntap-20230427-0007/"
},
{
"url": "https://security.gentoo.org/glsa/202310-12"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2022-43551",
"datePublished": "2022-12-23T00:00:00.000Z",
"dateReserved": "2022-10-20T00:00:00.000Z",
"dateUpdated": "2026-02-13T19:43:56.236Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-41983 (GCVE-0-2022-41983)
Vulnerability from cvelistv5 – Published: 2022-10-19 21:26 – Updated: 2025-05-08 18:08- CWE-319 - Cleartext Transmission of Sensitive Information
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T12:56:39.190Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.f5.com/csp/article/K31523465"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-41983",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-08T18:08:12.723185Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-08T18:08:24.000Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "BIG-IP",
"vendor": "F5",
"versions": [
{
"lessThan": "17.0.x*",
"status": "unaffected",
"version": "17.0.0",
"versionType": "custom"
},
{
"lessThan": "16.1.3.1",
"status": "affected",
"version": "16.1.x",
"versionType": "custom"
},
{
"lessThan": "15.1.7",
"status": "affected",
"version": "15.1.x",
"versionType": "custom"
},
{
"lessThan": "14.1.5.1",
"status": "affected",
"version": "14.1.x",
"versionType": "custom"
},
{
"lessThan": "13.1.x*",
"status": "affected",
"version": "13.1.0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "This issue was discovered internally by F5."
}
],
"datePublic": "2022-10-19T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "On specific hardware platforms, on BIG-IP versions 16.1.x before 16.1.3.1, 15.1.x before 15.1.7, 14.1.x before 14.1.5.1, and all versions of 13.1.x, while Intel QAT (QuickAssist Technology) and the AES-GCM/CCM cipher is in use, undisclosed conditions can cause BIG-IP to send data unencrypted even with an SSL Profile applied."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.7,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319 Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-10-19T00:00:00.000Z",
"orgId": "9dacffd4-cb11-413f-8451-fbbfd4ddc0ab",
"shortName": "f5"
},
"references": [
{
"url": "https://support.f5.com/csp/article/K31523465"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "BIG-IP TMM Vulnerability CVE-2022-41983",
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "9dacffd4-cb11-413f-8451-fbbfd4ddc0ab",
"assignerShortName": "f5",
"cveId": "CVE-2022-41983",
"datePublished": "2022-10-19T21:26:09.588Z",
"dateReserved": "2022-09-30T00:00:00.000Z",
"dateUpdated": "2025-05-08T18:08:24.000Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-41636 (GCVE-0-2022-41636)
Vulnerability from cvelistv5 – Published: 2022-10-28 17:12 – Updated: 2025-04-16 16:07- CWE-319 - Cleartext Transmission of Sensitive Information
| Vendor | Product | Version | |
|---|---|---|---|
| Haas | Haas CNC Controller |
Affected:
Version 100.20.000.1110
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T12:49:43.597Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-01"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-41636",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:53:04.555092Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:07:21.818Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Haas CNC Controller",
"vendor": "Haas",
"versions": [
{
"status": "affected",
"version": "Version 100.20.000.1110"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Marco Balduzzi of Trend Micro and Francesco Sortino from Celada Spa reported this vulnerability."
}
],
"datePublic": "2022-10-25T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Communication traffic involving \"Ethernet Q Commands\" service of Haas Controller version 100.20.000.1110 is transmitted in cleartext. This allows an attacker to obtain sensitive information being passed to and from the controller."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319 Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-10-28T00:00:00.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-01"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-41636",
"datePublished": "2022-10-28T17:12:20.666Z",
"dateReserved": "2022-09-29T00:00:00.000Z",
"dateUpdated": "2025-04-16T16:07:21.818Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-41327 (GCVE-0-2022-41327)
Vulnerability from cvelistv5 – Published: 2023-06-13 08:41 – Updated: 2024-10-23 14:27- CWE-319 - Information disclosure
| Vendor | Product | Version | |
|---|---|---|---|
| Fortinet | FortiOS |
Affected:
7.2.0 , ≤ 7.2.3
(semver)
Affected: 7.0.0 , ≤ 7.0.8 (semver) |
|
| Fortinet | FortiProxy |
Affected:
7.2.0 , ≤ 7.2.1
(semver)
Affected: 7.0.0 , ≤ 7.0.7 (semver) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T12:42:44.712Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://fortiguard.com/psirt/FG-IR-22-380",
"tags": [
"x_transferred"
],
"url": "https://fortiguard.com/psirt/FG-IR-22-380"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-41327",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-23T14:11:01.701994Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-23T14:27:14.451Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FortiOS",
"vendor": "Fortinet",
"versions": [
{
"lessThanOrEqual": "7.2.3",
"status": "affected",
"version": "7.2.0",
"versionType": "semver"
},
{
"lessThanOrEqual": "7.0.8",
"status": "affected",
"version": "7.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FortiProxy",
"vendor": "Fortinet",
"versions": [
{
"lessThanOrEqual": "7.2.1",
"status": "affected",
"version": "7.2.0",
"versionType": "semver"
},
{
"lessThanOrEqual": "7.0.7",
"status": "affected",
"version": "7.0.0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A cleartext transmission of sensitive information vulnerability [CWE-319] in Fortinet FortiOS version 7.2.0 through 7.2.4, 7.0.0 through 7.0.8, FortiProxy version 7.2.0 through 7.2.1 and 7.0.0 through 7.0.8 allows an authenticated attacker with readonly superadmin privileges to intercept traffic in order to obtain other adminstrators cookies via diagnose CLI commands."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:F/RL:X/RC:C",
"version": "3.1"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "Information disclosure",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-06-13T08:41:41.742Z",
"orgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8",
"shortName": "fortinet"
},
"references": [
{
"name": "https://fortiguard.com/psirt/FG-IR-22-380",
"url": "https://fortiguard.com/psirt/FG-IR-22-380"
}
],
"solutions": [
{
"lang": "en",
"value": "Please upgrade to FortiOS version 7.2.5 or above\r\nPlease upgrade to FortiOS version 7.0.9 or above\r\nPlease upgrade to FortiProxy version 7.2.2 or above\r\nPlease upgrade to FortiProxy version 7.0.8 or above"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8",
"assignerShortName": "fortinet",
"cveId": "CVE-2022-41327",
"datePublished": "2023-06-13T08:41:41.742Z",
"dateReserved": "2022-09-23T15:07:35.780Z",
"dateUpdated": "2024-10-23T14:27:14.451Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-40693 (GCVE-0-2022-40693)
Vulnerability from cvelistv5 – Published: 2023-02-07 16:52 – Updated: 2024-08-03 12:21- CWE-319 - Cleartext Transmission of Sensitive Information
| Vendor | Product | Version | |
|---|---|---|---|
| Moxa | SDS-3008 Series Industrial Ethernet Switch |
Affected:
2.1
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T12:21:46.601Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2022-1616"
},
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1616",
"tags": [
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1616"
},
{
"name": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities",
"tags": [
"x_transferred"
],
"url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-40693",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-01T15:48:00.655638Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-01T15:49:15.722Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "SDS-3008 Series Industrial Ethernet Switch",
"vendor": "Moxa",
"versions": [
{
"status": "affected",
"version": "2.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A cleartext transmission vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted network sniffing can lead to a disclosure of sensitive information. An attacker can sniff network traffic to trigger this vulnerability."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319: Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-07T16:52:04.022Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1616",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1616"
},
{
"name": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities",
"url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2022-40693",
"datePublished": "2023-02-07T16:52:04.022Z",
"dateReserved": "2022-09-20T20:07:00.466Z",
"dateUpdated": "2024-08-03T12:21:46.601Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Mitigation
Before transmitting, encrypt the data using reliable, confidentiality-protecting cryptographic protocols.
Mitigation
When using web applications with SSL, use SSL for the entire session from login to logout, not just for the initial login page.
Mitigation
When designing hardware platforms, ensure that approved encryption algorithms (such as those recommended by NIST) protect paths from security critical data to trusted user applications.
Mitigation
Use tools and techniques that require manual (human) analysis, such as penetration testing, threat modeling, and interactive tools that allow the tester to record and modify an active session. These may be more effective than strictly automated techniques. This is especially the case with weaknesses that are related to design and business rules.
Mitigation
Configure servers to use encrypted channels for communication, which may include SSL or other secure protocols.
CAPEC-102: Session Sidejacking
Session sidejacking takes advantage of an unencrypted communication channel between a victim and target system. The attacker sniffs traffic on a network looking for session tokens in unencrypted traffic. Once a session token is captured, the attacker performs malicious actions by using the stolen token with the targeted application to impersonate the victim. This attack is a specific method of session hijacking, which is exploiting a valid session token to gain unauthorized access to a target system or information. Other methods to perform a session hijacking are session fixation, cross-site scripting, or compromising a user or server machine and stealing the session token.
CAPEC-117: Interception
An adversary monitors data streams to or from the target for information gathering purposes. This attack may be undertaken to solely gather sensitive information or to support a further attack against the target. This attack pattern can involve sniffing network traffic as well as other types of data streams (e.g. radio). The adversary can attempt to initiate the establishment of a data stream or passively observe the communications as they unfold. In all variants of this attack, the adversary is not the intended recipient of the data stream. In contrast to other means of gathering information (e.g., targeting data leaks), the adversary must actively position themself so as to observe explicit data channels (e.g. network traffic) and read the content. However, this attack differs from a Adversary-In-the-Middle (CAPEC-94) attack, as the adversary does not alter the content of the communications nor forward data to the intended recipient.
CAPEC-383: Harvesting Information via API Event Monitoring
An adversary hosts an event within an application framework and then monitors the data exchanged during the course of the event for the purpose of harvesting any important data leaked during the transactions. One example could be harvesting lists of usernames or userIDs for the purpose of sending spam messages to those users. One example of this type of attack involves the adversary creating an event within the sub-application. Assume the adversary hosts a "virtual sale" of rare items. As other users enter the event, the attacker records via AiTM (CAPEC-94) proxy the user_ids and usernames of everyone who attends. The adversary would then be able to spam those users within the application using an automated script.
CAPEC-477: Signature Spoofing by Mixing Signed and Unsigned Content
An attacker exploits the underlying complexity of a data structure that allows for both signed and unsigned content, to cause unsigned data to be processed as though it were signed data.
CAPEC-65: Sniff Application Code
An adversary passively sniffs network communications and captures application code bound for an authorized client. Once obtained, they can use it as-is, or through reverse-engineering glean sensitive information or exploit the trust relationship between the client and server. Such code may belong to a dynamic update to the client, a patch being applied to a client component or any such interaction where the client is authorized to communicate with the server.