Common Weakness Enumeration

CWE-319

Allowed

Cleartext Transmission of Sensitive Information

Abstraction: Base · Status: Draft

The product transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors.

1147 vulnerabilities reference this CWE, most recent first.

CVE-2022-21951 (GCVE-0-2022-21951)

Vulnerability from cvelistv5 – Published: 2022-05-25 08:15 – Updated: 2024-09-16 21:04
VLAI
Title
Rancher: Weave CNI password is not set if RKE template is used with CNI value overridden
Summary
A Cleartext Transmission of Sensitive Information vulnerability in SUSE Rancher, Rancher allows attackers on the network to read and change network data due to missing encryption of data transmitted via the network when a cluster is created from an RKE template with the CNI value overridden This issue affects: SUSE Rancher Rancher versions prior to 2.5.14; Rancher versions prior to 2.6.5.
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
Impacted products
Vendor Product Version
SUSE Rancher Affected: Rancher , < 2.5.14 (custom)
Create a notification for this product.
SUSE Rancher Affected: Rancher , < 2.6.5 (custom)
Create a notification for this product.
Date Public
2022-05-24 22:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:00:54.452Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://bugzilla.suse.com/show_bug.cgi?id=1199443"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://github.com/rancher/rancher/security/advisories/GHSA-vrph-m5jj-c46c"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Rancher",
          "vendor": "SUSE",
          "versions": [
            {
              "lessThan": "2.5.14",
              "status": "affected",
              "version": "Rancher",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Rancher",
          "vendor": "SUSE",
          "versions": [
            {
              "lessThan": "2.6.5",
              "status": "affected",
              "version": "Rancher",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-05-24T22:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eA Cleartext Transmission of Sensitive Information vulnerability in SUSE Rancher, Rancher allows attackers on the network to read and change network data due to missing encryption of data transmitted via the network when a cluster is created from an RKE template with the CNI value overridden This issue affects: SUSE Rancher Rancher versions prior to 2.5.14; Rancher versions prior to 2.6.5.\u003c/p\u003e"
            }
          ],
          "value": "A Cleartext Transmission of Sensitive Information vulnerability in SUSE Rancher, Rancher allows attackers on the network to read and change network data due to missing encryption of data transmitted via the network when a cluster is created from an RKE template with the CNI value overridden This issue affects: SUSE Rancher Rancher versions prior to 2.5.14; Rancher versions prior to 2.6.5."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319: Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-07-26T14:44:47.345Z",
        "orgId": "404e59f5-483d-4b8a-8e7a-e67604dd8afb",
        "shortName": "suse"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://bugzilla.suse.com/show_bug.cgi?id=1199443"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/rancher/rancher/security/advisories/GHSA-vrph-m5jj-c46c"
        }
      ],
      "source": {
        "advisory": "https://bugzilla.suse.com/show_bug.cgi?id=1199443",
        "defect": [
          "1199443"
        ],
        "discovery": "INTERNAL"
      },
      "title": "Rancher: Weave CNI password is not set if RKE template is used with CNI value overridden",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security@suse.com",
          "DATE_PUBLIC": "2022-05-25T00:00:00.000Z",
          "ID": "CVE-2022-21951",
          "STATE": "PUBLIC",
          "TITLE": "Rancher: Weave CNI password is not set if RKE template is used with CNI value overridden"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Rancher",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "Rancher",
                            "version_value": "2.5.14"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Rancher",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "Rancher",
                            "version_value": "2.6.5"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "SUSE"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A Missing Encryption of Sensitive Data vulnerability in SUSE Rancher, Rancher allows attackers on the network to read and change network data due to missing encryption of data transmitted via the network when a cluster is created from an RKE template with the CNI value overridden This issue affects: SUSE Rancher Rancher versions prior to 2.5.14; Rancher versions prior to 2.6.5."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-311: Missing Encryption of Sensitive Data"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://bugzilla.suse.com/show_bug.cgi?id=1199443",
              "refsource": "CONFIRM",
              "url": "https://bugzilla.suse.com/show_bug.cgi?id=1199443"
            },
            {
              "name": "https://github.com/rancher/rancher/security/advisories/GHSA-vrph-m5jj-c46c",
              "refsource": "CONFIRM",
              "url": "https://github.com/rancher/rancher/security/advisories/GHSA-vrph-m5jj-c46c"
            }
          ]
        },
        "source": {
          "advisory": "https://bugzilla.suse.com/show_bug.cgi?id=1199443",
          "defect": [
            "1199443"
          ],
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "404e59f5-483d-4b8a-8e7a-e67604dd8afb",
    "assignerShortName": "suse",
    "cveId": "CVE-2022-21951",
    "datePublished": "2022-05-25T08:15:21.578Z",
    "dateReserved": "2021-12-16T00:00:00.000Z",
    "dateUpdated": "2024-09-16T21:04:23.284Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-21829 (GCVE-0-2022-21829)

Vulnerability from cvelistv5 – Published: 2022-06-24 15:00 – Updated: 2024-08-03 02:53
VLAI
Summary
Concrete CMS Versions 9.0.0 through 9.0.2 and 8.5.7 and below can download zip files over HTTP and execute code from those zip files which could lead to an RCE. Fixed by enforcing ‘concrete_secure’ instead of ‘concrete’. Concrete now only makes requests over https even a request comes in via http. Concrete CMS security team ranked this 8 with CVSS v3.1 vector: AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H Credit goes to Anna for reporting HackerOne 1482520.
Severity
No CVSS data available.
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information (CWE-319)
Assigner
Impacted products
Vendor Product Version
n/a https://github.com/concrete5/concrete5 Affected: Remediated in Concrete CMS 8.5.8 and 9.1.0. Affected Versions are Concrete 8.5.7 and below as well as Concrete 9.0 through 9.0.2
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T02:53:36.288Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://documentation.concretecms.org/developers/introduction/version-history/858-release-notes"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://hackerone.com/reports/1482520%2C"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://documentation.concretecms.org/developers/introduction/version-history/910-release-notes%2C"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "https://github.com/concrete5/concrete5",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Remediated in Concrete CMS 8.5.8 and 9.1.0.    Affected Versions are Concrete 8.5.7 and below  as well as Concrete 9.0 through 9.0.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Concrete CMS Versions 9.0.0 through 9.0.2 and 8.5.7 and below can download zip files over HTTP and execute code from those zip files which could lead to an RCE. Fixed by enforcing \u2018concrete_secure\u2019 instead of \u2018concrete\u2019. Concrete now only makes requests over https even a request comes in via http. Concrete CMS security team ranked this 8 with CVSS v3.1 vector: AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H Credit goes to Anna for reporting HackerOne 1482520."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "Cleartext Transmission of Sensitive Information (CWE-319)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-24T15:00:05.000Z",
        "orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
        "shortName": "hackerone"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://documentation.concretecms.org/developers/introduction/version-history/858-release-notes"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://hackerone.com/reports/1482520%2C"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://documentation.concretecms.org/developers/introduction/version-history/910-release-notes%2C"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "support@hackerone.com",
          "ID": "CVE-2022-21829",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "https://github.com/concrete5/concrete5",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Remediated in Concrete CMS 8.5.8 and 9.1.0.    Affected Versions are Concrete 8.5.7 and below  as well as Concrete 9.0 through 9.0.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Concrete CMS Versions 9.0.0 through 9.0.2 and 8.5.7 and below can download zip files over HTTP and execute code from those zip files which could lead to an RCE. Fixed by enforcing \u2018concrete_secure\u2019 instead of \u2018concrete\u2019. Concrete now only makes requests over https even a request comes in via http. Concrete CMS security team ranked this 8 with CVSS v3.1 vector: AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H Credit goes to Anna for reporting HackerOne 1482520."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Cleartext Transmission of Sensitive Information (CWE-319)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://documentation.concretecms.org/developers/introduction/version-history/858-release-notes",
              "refsource": "MISC",
              "url": "https://documentation.concretecms.org/developers/introduction/version-history/858-release-notes"
            },
            {
              "name": "https://hackerone.com/reports/1482520,",
              "refsource": "MISC",
              "url": "https://hackerone.com/reports/1482520,"
            },
            {
              "name": "https://documentation.concretecms.org/developers/introduction/version-history/910-release-notes,",
              "refsource": "MISC",
              "url": "https://documentation.concretecms.org/developers/introduction/version-history/910-release-notes,"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
    "assignerShortName": "hackerone",
    "cveId": "CVE-2022-21829",
    "datePublished": "2022-06-24T15:00:05.000Z",
    "dateReserved": "2021-12-10T00:00:00.000Z",
    "dateUpdated": "2024-08-03T02:53:36.288Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-21798 (GCVE-0-2022-21798)

Vulnerability from cvelistv5 – Published: 2022-02-25 18:10 – Updated: 2025-04-16 18:00
VLAI
Title
ICSA-22-053-02 GE Proficy CIMPLICITY-Cleartext
Summary
The affected product is vulnerable due to cleartext transmission of credentials seen in the CIMPLICITY network, which can be easily spoofed and used to log in to make operational changes to the system.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
Impacted products
Date Public
2022-02-22 00:00
Credits
Yuval Ardon and Roman Dvorkin of OTORIO reported this vulnerability to CISA
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T02:53:36.261Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-053-02"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-21798",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T17:31:09.941294Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T18:00:26.255Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Proficy CIMPLICITY",
          "vendor": "General Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Yuval Ardon and Roman Dvorkin of OTORIO reported this vulnerability to CISA"
        }
      ],
      "datePublic": "2022-02-22T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "The affected product is vulnerable due to cleartext transmission of credentials seen in the CIMPLICITY network, which can be easily spoofed and used to log in to make operational changes to the system."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319 Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-02-25T18:10:56.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-053-02"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Users are advised to refer to the Secure Deployment Guide on how to configure communication encryption.\n\nUsers are encouraged to review the CIMPLICITY Windows Hardening Guide and Recommendations for further IPSEC configuration guidance found in the section titled \u201cAppendix A IPSEC Configuration.\u201d\n\nUsers are encouraged to contact a GE representative to obtain the latest versions of CIMPLICITY."
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "ICSA-22-053-02 GE Proficy CIMPLICITY-Cleartext",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2022-02-22T23:08:00.000Z",
          "ID": "CVE-2022-21798",
          "STATE": "PUBLIC",
          "TITLE": "ICSA-22-053-02 GE Proficy CIMPLICITY-Cleartext"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Proficy CIMPLICITY",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_name": "all",
                            "version_value": "all"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "General Electric"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Yuval Ardon and Roman Dvorkin of OTORIO reported this vulnerability to CISA"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The affected product is vulnerable due to cleartext transmission of credentials seen in the CIMPLICITY network, which can be easily spoofed and used to log in to make operational changes to the system."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-319 Cleartext Transmission of Sensitive Information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-053-02",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-053-02"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Users are advised to refer to the Secure Deployment Guide on how to configure communication encryption.\n\nUsers are encouraged to review the CIMPLICITY Windows Hardening Guide and Recommendations for further IPSEC configuration guidance found in the section titled \u201cAppendix A IPSEC Configuration.\u201d\n\nUsers are encouraged to contact a GE representative to obtain the latest versions of CIMPLICITY."
          }
        ],
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-21798",
    "datePublished": "2022-02-25T18:10:56.670Z",
    "dateReserved": "2022-01-27T00:00:00.000Z",
    "dateUpdated": "2025-04-16T18:00:26.255Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-21184 (GCVE-0-2022-21184)

Vulnerability from cvelistv5 – Published: 2022-06-17 17:40 – Updated: 2025-04-15 19:00
VLAI
Summary
An information disclosure vulnerability exists in the License registration functionality of Bachmann Visutec GmbH Atvise 3.5.4, 3.6 and 3.7. A plaintext HTTP request can lead to a disclosure of login credentials. An attacker can perform a man-in-the-middle attack to trigger this vulnerability.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
Impacted products
Vendor Product Version
Bachmann Visutec GmbH Atvise Affected: 3.5.4
Affected: 3.6
Affected: 3.7
Create a notification for this product.
Date Public
2022-06-15 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T02:31:59.662Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1461"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-21184",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-15T18:14:14.947480Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-15T19:00:38.753Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Atvise",
          "vendor": "Bachmann Visutec GmbH",
          "versions": [
            {
              "status": "affected",
              "version": "3.5.4"
            },
            {
              "status": "affected",
              "version": "3.6"
            },
            {
              "status": "affected",
              "version": "3.7"
            }
          ]
        }
      ],
      "datePublic": "2022-06-15T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An information disclosure vulnerability exists in the License registration functionality of Bachmann Visutec GmbH Atvise 3.5.4, 3.6 and 3.7. A plaintext HTTP request can lead to a disclosure of login credentials. An attacker can perform a man-in-the-middle attack to trigger this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319: Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-17T17:40:11.000Z",
        "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
        "shortName": "talos"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1461"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "talos-cna@cisco.com",
          "DATE_PUBLIC": "2022-06-15",
          "ID": "CVE-2022-21184",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Atvise",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "3.5.4"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "3.6"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "3.7"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Bachmann Visutec GmbH"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An information disclosure vulnerability exists in the License registration functionality of Bachmann Visutec GmbH Atvise 3.5.4, 3.6 and 3.7. A plaintext HTTP request can lead to a disclosure of login credentials. An attacker can perform a man-in-the-middle attack to trigger this vulnerability."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 5.9,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-319: Cleartext Transmission of Sensitive Information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1461",
              "refsource": "MISC",
              "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1461"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
    "assignerShortName": "talos",
    "cveId": "CVE-2022-21184",
    "datePublished": "2022-06-17T17:40:12.075Z",
    "dateReserved": "2022-01-25T00:00:00.000Z",
    "dateUpdated": "2025-04-15T19:00:38.753Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-3929 (GCVE-0-2022-3929)

Vulnerability from cvelistv5 – Published: 2023-01-05 21:54 – Updated: 2025-04-10 13:51
VLAI
Title
Communication between the client and server partially using CORBA over TCP/IP
Summary
Communication between the client and the server application of the affected products is partially done using CORBA (Common Object Request Broker Architecture) over TCP/IP. This protocol is not encrypted and allows tracing of internal messages. This issue affects * FOXMAN-UN product: FOXMAN-UN R15B, FOXMAN-UN R15A, FOXMAN-UN R14B, FOXMAN-UN R14A, FOXMAN-UN R11B, FOXMAN-UN R11A, FOXMAN-UN R10C, FOXMAN-UN R9C; * UNEM product: UNEM R15B, UNEM R15A, UNEM R14B, UNEM R14A, UNEM R11B, UNEM R11A, UNEM R10C, UNEM R9C. List of CPEs: * cpe:2.3:a:hitachienergy:foxman-un:R15B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R15A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R14B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R14A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R11B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R11A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R10C:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R9C:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R15B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R15A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R14B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R14A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R11B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R11A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R10C:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R9C:*:*:*:*:*:*:*
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
Impacted products
Vendor Product Version
Hitachi Energy FOXMAN-UN Unaffected: FOXMAN-UN R16A
Affected: FOXMAN-UN R15B
Affected: FOXMAN-UN R15A
Affected: FOXMAN-UN R14B
Affected: FOXMAN-UN R14A
Affected: FOXMAN-UN R11B
Affected: FOXMAN-UN R11A
Affected: FOXMAN-UN R10C
Affected: FOXMAN-UN R9C
Create a notification for this product.
Hitachi Energy UNEM Unaffected: UNEM R16A
Affected: UNEM R15B
Affected: UNEM R15A
Affected: UNEM R14B
Affected: UNEM R14A
Affected: UNEM R11B
Affected: UNEM R11A
Affected: UNEM R10C
Affected: UNEM R9C
Create a notification for this product.
Date Public
2022-12-13 13:30
Credits
K-Businessom AG, Austria
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T01:27:54.099Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000083\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000084\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-3929",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-10T13:51:05.411841Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-10T13:51:12.769Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "FOXMAN-UN",
          "vendor": "Hitachi Energy",
          "versions": [
            {
              "status": "unaffected",
              "version": "FOXMAN-UN R16A"
            },
            {
              "status": "affected",
              "version": "FOXMAN-UN R15B"
            },
            {
              "status": "affected",
              "version": "FOXMAN-UN R15A"
            },
            {
              "status": "affected",
              "version": "FOXMAN-UN R14B"
            },
            {
              "status": "affected",
              "version": "FOXMAN-UN R14A"
            },
            {
              "status": "affected",
              "version": "FOXMAN-UN R11B"
            },
            {
              "status": "affected",
              "version": "FOXMAN-UN R11A"
            },
            {
              "status": "affected",
              "version": "FOXMAN-UN R10C"
            },
            {
              "status": "affected",
              "version": "FOXMAN-UN R9C"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "UNEM",
          "vendor": "Hitachi Energy",
          "versions": [
            {
              "status": "unaffected",
              "version": "UNEM R16A"
            },
            {
              "status": "affected",
              "version": "UNEM R15B"
            },
            {
              "status": "affected",
              "version": "UNEM R15A"
            },
            {
              "status": "affected",
              "version": "UNEM R14B"
            },
            {
              "status": "affected",
              "version": "UNEM R14A"
            },
            {
              "status": "affected",
              "version": "UNEM R11B"
            },
            {
              "status": "affected",
              "version": "UNEM R11A"
            },
            {
              "status": "affected",
              "version": "UNEM R10C"
            },
            {
              "status": "affected",
              "version": "UNEM R9C"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "K-Businessom AG, Austria"
        }
      ],
      "datePublic": "2022-12-13T13:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\nCommunication between the client and the server application of the affected products is partially done using CORBA (Common Object Request Broker Architecture) over TCP/IP. This protocol is not encrypted and allows tracing of internal messages.\u003cbr\u003e\u003cp\u003e\u003c/p\u003e\u003cp\u003eThis issue affects \u003c/p\u003e\u003cp\u003e\u003c/p\u003e\u003cul\u003e\u003cli\u003eFOXMAN-UN product: FOXMAN-UN R15B, FOXMAN-UN R15A, FOXMAN-UN R14B, FOXMAN-UN R14A, FOXMAN-UN R11B, FOXMAN-UN R11A, FOXMAN-UN R10C, FOXMAN-UN R9C; \u003c/li\u003e\u003cli\u003eUNEM product: UNEM R15B, UNEM R15A, UNEM R14B, UNEM R14A, UNEM R11B, UNEM R11A, UNEM R10C, UNEM R9C.\u003c/li\u003e\u003c/ul\u003e\u003cp\u003e\u003c/p\u003eList of CPEs: \u003cbr\u003e\u003cul\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:a:hitachienergy:foxman-un:R15B:*:*:*:*:*:*:*\u003c/span\u003e\u003cbr\u003e\u003c/li\u003e\u003cli\u003ecpe:2.3:a:hitachienergy:foxman-un:R15A:*:*:*:*:*:*:*\u003c/li\u003e\u003cli\u003ecpe:2.3:a:hitachienergy:foxman-un:R14B:*:*:*:*:*:*:*\u003c/li\u003e\u003cli\u003ecpe:2.3:a:hitachienergy:foxman-un:R14A:*:*:*:*:*:*:*\u003c/li\u003e\u003cli\u003ecpe:2.3:a:hitachienergy:foxman-un:R11B:*:*:*:*:*:*:*\u003c/li\u003e\u003cli\u003ecpe:2.3:a:hitachienergy:foxman-un:R11A:*:*:*:*:*:*:*\u003c/li\u003e\u003cli\u003ecpe:2.3:a:hitachienergy:foxman-un:R10C:*:*:*:*:*:*:*\u003c/li\u003e\u003cli\u003ecpe:2.3:a:hitachienergy:foxman-un:R9C:*:*:*:*:*:*:*\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:a:hitachienergy:unem:R15B:*:*:*:*:*:*:*\u003c/span\u003e\u003cbr\u003e\u003c/li\u003e\u003cli\u003ecpe:2.3:a:hitachienergy:unem:R15A:*:*:*:*:*:*:*\u003c/li\u003e\u003cli\u003ecpe:2.3:a:hitachienergy:unem:R14B:*:*:*:*:*:*:*\u003c/li\u003e\u003cli\u003ecpe:2.3:a:hitachienergy:unem:R14A:*:*:*:*:*:*:*\u003c/li\u003e\u003cli\u003ecpe:2.3:a:hitachienergy:unem:R11B:*:*:*:*:*:*:*\u003c/li\u003e\u003cli\u003ecpe:2.3:a:hitachienergy:unem:R11A:*:*:*:*:*:*:*\u003c/li\u003e\u003cli\u003ecpe:2.3:a:hitachienergy:unem:R10C:*:*:*:*:*:*:*\u003c/li\u003e\u003cli\u003ecpe:2.3:a:hitachienergy:unem:R9C:*:*:*:*:*:*:*\u003c/li\u003e\u003c/ul\u003e\u003cp\u003e\u003c/p\u003e\n\n\u003cp\u003e\u003c/p\u003e"
            }
          ],
          "value": "\nCommunication between the client and the server application of the affected products is partially done using CORBA (Common Object Request Broker Architecture) over TCP/IP. This protocol is not encrypted and allows tracing of internal messages.\n\n\nThis issue affects \n\n\n\n  *  FOXMAN-UN product: FOXMAN-UN R15B, FOXMAN-UN R15A, FOXMAN-UN R14B, FOXMAN-UN R14A, FOXMAN-UN R11B, FOXMAN-UN R11A, FOXMAN-UN R10C, FOXMAN-UN R9C; \n  *  UNEM product: UNEM R15B, UNEM R15A, UNEM R14B, UNEM R14A, UNEM R11B, UNEM R11A, UNEM R10C, UNEM R9C.\n\n\n\n\nList of CPEs: \n  *  cpe:2.3:a:hitachienergy:foxman-un:R15B:*:*:*:*:*:*:*\n\n  *  cpe:2.3:a:hitachienergy:foxman-un:R15A:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:foxman-un:R14B:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:foxman-un:R14A:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:foxman-un:R11B:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:foxman-un:R11A:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:foxman-un:R10C:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:foxman-un:R9C:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:unem:R15B:*:*:*:*:*:*:*\n\n  *  cpe:2.3:a:hitachienergy:unem:R15A:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:unem:R14B:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:unem:R14A:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:unem:R11B:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:unem:R11A:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:unem:R10C:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:unem:R9C:*:*:*:*:*:*:*\n\n\n\n\n\n\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-158",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-158 Sniffing Network Traffic"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319 Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-01-05T21:54:51.823Z",
        "orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
        "shortName": "Hitachi Energy"
      },
      "references": [
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000083\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        },
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000084\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Communication between the client and server partially using CORBA over TCP/IP",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\nFor immediate recommended mitigation actions if using FOXMAN-UN R15B or UNEM R15B and earlier, please refer to the multiple clauses of section Mitigation Factors/Workarounds in the advisory\u003cbr\u003e\u003cul\u003e\u003cli\u003eSecure the NMS CLIENT/SERVER communication.\u003c/li\u003e\u003c/ul\u003e\n\n"
            }
          ],
          "value": "\nFor immediate recommended mitigation actions if using FOXMAN-UN R15B or UNEM R15B and earlier, please refer to the multiple clauses of section Mitigation Factors/Workarounds in the advisory\n  *  Secure the NMS CLIENT/SERVER communication.\n\n\n\n\n"
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
    "assignerShortName": "Hitachi Energy",
    "cveId": "CVE-2022-3929",
    "datePublished": "2023-01-05T21:54:51.823Z",
    "dateReserved": "2022-11-10T15:40:42.305Z",
    "dateUpdated": "2025-04-10T13:51:12.769Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-2485 (GCVE-0-2022-2485)

Vulnerability from cvelistv5 – Published: 2022-08-31 15:59 – Updated: 2025-04-16 17:49
VLAI
Title
AutomationDirect Stride Field I/O Cleartext Transmission of Sensitive Information
Summary
Any attempt (good or bad) to log into AutomationDirect Stride Field I/O with a web browser may result in the device responding with its password in the communication packets.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
Impacted products
Vendor Product Version
AutomationDirect SIO-MB04RTDS Affected: unspecified , < 8.3.4.0 (custom)
Create a notification for this product.
AutomationDirect SIO- MB04ADS Affected: unspecified , < 8.4.3.0 (custom)
Create a notification for this product.
AutomationDirect SIO-MB04THMS Affected: unspecified , < 8.5.4.0 (custom)
Create a notification for this product.
AutomationDirect SIO-MB08ADS-1 Affected: unspecified , < 8.6.3.0 (custom)
Create a notification for this product.
AutomationDirect SIO-MB08ADS-2 Affected: unspecified , < 8.7.3.0 (custom)
Create a notification for this product.
AutomationDirect SIO-MB08THMS Affected: unspecified , < 8.8.4.0 (custom)
Create a notification for this product.
AutomationDirect SIO-MB04DAS Affected: unspecified , < 8.11.3.0 (custom)
Create a notification for this product.
AutomationDirect SIO-MB12CDR Affected: unspecified , < 8.0.4.0 (custom)
Create a notification for this product.
AutomationDirect SIO-MB16CDD2 Affected: unspecified , < 8.1.4.0 (custom)
Create a notification for this product.
AutomationDirect SIO-MB16ND3 Affected: unspecified , < 8.2.4.00 (custom)
Create a notification for this product.
AutomationDirect SIO-MB12CDR Affected: batch number (B/N) 5714442222
Create a notification for this product.
AutomationDirect SIO-MB04ADS Affected: B/N 5714442222
Create a notification for this product.
AutomationDirect SIO-MB04THMS Affected: B/N 57141862221
Create a notification for this product.
AutomationDirect SIO-MB04DAS Affected: B/N 4714432222
Create a notification for this product.
Credits
Byron Chaney of Accenture Security reported this vulnerability to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:39:07.846Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-202-05"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cdn.automationdirect.com/static/firmware/product_advisory/PA-COM-006.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-2485",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T17:27:39.794007Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T17:49:04.112Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIO-MB04RTDS",
          "vendor": "AutomationDirect",
          "versions": [
            {
              "lessThan": "8.3.4.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "SIO- MB04ADS",
          "vendor": "AutomationDirect",
          "versions": [
            {
              "lessThan": "8.4.3.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "SIO-MB04THMS",
          "vendor": "AutomationDirect",
          "versions": [
            {
              "lessThan": "8.5.4.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "SIO-MB08ADS-1",
          "vendor": "AutomationDirect",
          "versions": [
            {
              "lessThan": "8.6.3.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "SIO-MB08ADS-2",
          "vendor": "AutomationDirect",
          "versions": [
            {
              "lessThan": "8.7.3.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "SIO-MB08THMS",
          "vendor": "AutomationDirect",
          "versions": [
            {
              "lessThan": "8.8.4.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "SIO-MB04DAS",
          "vendor": "AutomationDirect",
          "versions": [
            {
              "lessThan": "8.11.3.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "SIO-MB12CDR",
          "vendor": "AutomationDirect",
          "versions": [
            {
              "lessThan": "8.0.4.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "SIO-MB16CDD2",
          "vendor": "AutomationDirect",
          "versions": [
            {
              "lessThan": "8.1.4.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "SIO-MB16ND3",
          "vendor": "AutomationDirect",
          "versions": [
            {
              "lessThan": "8.2.4.00",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "SIO-MB12CDR",
          "vendor": "AutomationDirect",
          "versions": [
            {
              "status": "affected",
              "version": "batch number (B/N) 5714442222"
            }
          ]
        },
        {
          "product": "SIO-MB04ADS",
          "vendor": "AutomationDirect",
          "versions": [
            {
              "status": "affected",
              "version": "B/N 5714442222"
            }
          ]
        },
        {
          "product": "SIO-MB04THMS",
          "vendor": "AutomationDirect",
          "versions": [
            {
              "status": "affected",
              "version": "B/N 57141862221"
            }
          ]
        },
        {
          "product": "SIO-MB04DAS",
          "vendor": "AutomationDirect",
          "versions": [
            {
              "status": "affected",
              "version": "B/N 4714432222"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Byron Chaney of Accenture Security reported this vulnerability to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Any attempt (good or bad) to log into AutomationDirect Stride Field I/O with a web browser may result in the device responding with its password in the communication packets."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.6,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319: Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-31T15:59:34.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-202-05"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cdn.automationdirect.com/static/firmware/product_advisory/PA-COM-006.pdf"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "AutomationDirect recommends users upgrade the Stride Modbus Field I/O units listed in the affected products section with the firmware associated with the part number. Firmware can be downloaded from the AutomationDirect software downloads page.\n\nThe modules with a listed B/N number in the affected products section have a firmware update issue and must be returned to AutomationDirect for replacement modules; users can create an RMA on the AutomationDirect website.\n\nAutomation networks and systems may have built-in password protection schemes, but this is only one step in securing systems. Automation control system networks must incorporate data protection and security measures at least as robust as a typical business computer system. AutomationDirect recommends users of PLCs, HMI products and SCADA systems perform their own network security analysis to determine the proper level of security required for their application.\n\nSee AutomationDirect product advisory number PA-COM-006 for more information. "
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "AutomationDirect Stride Field I/O Cleartext Transmission of Sensitive Information",
      "workarounds": [
        {
          "lang": "en",
          "value": "AutomationDirect has identified the specific mitigation actions listed below:\n\nSecure physical access.\nIsolate and air gap networks when possible.\nFollow the security considerations in the Automation Direct Security Considerations document.\nhttps://support.automationdirect.com/docs/securityconsiderations.pdf"
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2022-2485",
          "STATE": "PUBLIC",
          "TITLE": "AutomationDirect Stride Field I/O Cleartext Transmission of Sensitive Information"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIO-MB04RTDS",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "8.3.4.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIO- MB04ADS",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "8.4.3.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIO-MB04THMS",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "8.5.4.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIO-MB08ADS-1",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "8.6.3.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIO-MB08ADS-2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "8.7.3.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIO-MB08THMS",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "8.8.4.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIO-MB04DAS",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "8.11.3.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIO-MB12CDR",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "8.0.4.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIO-MB16CDD2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "8.1.4.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIO-MB16ND3",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "8.2.4.00"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIO-MB12CDR",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "batch number (B/N) 5714442222"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIO-MB04ADS",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "B/N 5714442222"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIO-MB04THMS",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "B/N 57141862221"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIO-MB04DAS",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "B/N 4714432222"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "AutomationDirect"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Byron Chaney of Accenture Security reported this vulnerability to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Any attempt (good or bad) to log into AutomationDirect Stride Field I/O with a web browser may result in the device responding with its password in the communication packets."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.6,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-319: Cleartext Transmission of Sensitive Information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-202-05",
              "refsource": "CONFIRM",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-202-05"
            },
            {
              "name": "https://cdn.automationdirect.com/static/firmware/product_advisory/PA-COM-006.pdf",
              "refsource": "CONFIRM",
              "url": "https://cdn.automationdirect.com/static/firmware/product_advisory/PA-COM-006.pdf"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "AutomationDirect recommends users upgrade the Stride Modbus Field I/O units listed in the affected products section with the firmware associated with the part number. Firmware can be downloaded from the AutomationDirect software downloads page.\n\nThe modules with a listed B/N number in the affected products section have a firmware update issue and must be returned to AutomationDirect for replacement modules; users can create an RMA on the AutomationDirect website.\n\nAutomation networks and systems may have built-in password protection schemes, but this is only one step in securing systems. Automation control system networks must incorporate data protection and security measures at least as robust as a typical business computer system. AutomationDirect recommends users of PLCs, HMI products and SCADA systems perform their own network security analysis to determine the proper level of security required for their application.\n\nSee AutomationDirect product advisory number PA-COM-006 for more information. "
          }
        ],
        "source": {
          "discovery": "EXTERNAL"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "AutomationDirect has identified the specific mitigation actions listed below:\n\nSecure physical access.\nIsolate and air gap networks when possible.\nFollow the security considerations in the Automation Direct Security Considerations document.\nhttps://support.automationdirect.com/docs/securityconsiderations.pdf"
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-2485",
    "datePublished": "2022-08-31T15:59:34.000Z",
    "dateReserved": "2022-07-19T00:00:00.000Z",
    "dateUpdated": "2025-04-16T17:49:04.112Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-2338 (GCVE-0-2022-2338)

Vulnerability from cvelistv5 – Published: 2022-08-17 20:15 – Updated: 2025-04-16 16:12
VLAI
Title
Softing Secure Integration Server Cleartext Transmission of Sensitive Information
Summary
Softing Secure Integration Server V1.22 is vulnerable to authentication bypass via a machine-in-the-middle attack. The default the administration interface is accessible via plaintext HTTP protocol, facilitating the attack. The HTTP request may contain the session cookie in the request, which may be captured for use in authenticating to the server.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
Impacted products
Credits
Pedro Ribeiro and Radek Domanski, working with Trend Micro Zero Day Initiative, reported these vulnerabilities to Softing and CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:32:09.605Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-5.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-2338",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T15:50:48.300738Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T16:12:59.993Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Secure Integration Server",
          "vendor": "Softing",
          "versions": [
            {
              "status": "affected",
              "version": "V1.22"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Pedro Ribeiro and Radek Domanski, working with Trend Micro Zero Day Initiative, reported these vulnerabilities to Softing and CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Softing Secure Integration Server V1.22 is vulnerable to authentication bypass via a machine-in-the-middle attack. The default the administration interface is accessible via plaintext HTTP protocol, facilitating the attack. The HTTP request may contain the session cookie in the request, which may be captured for use in authenticating to the server."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319: Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-17T20:15:03.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-5.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Softing released new versions to address these vulnerabilities and notified known users of the releases. Users are advised to update to the new versions:\nSofting Secure Integration Server V1.30 \n\nThe latest software packages can be downloaded from the Softing website. \n\nSofting recommends the following mitigations and workarounds: \nChange the admin password or create a new user with administrative rights and delete the default admin user. \nConfigure the Windows firewall to block network requests to IP port 9000. \nDisable the HTTP Server in NGINX configuration of the Softing Secure Integration Server, only using the HTTPS server. \nFor more details on these vulnerabilities and mitigations, users should see SYT-2022-5 on the Softing security website."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Softing Secure Integration Server Cleartext Transmission of Sensitive Information",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2022-2338",
          "STATE": "PUBLIC",
          "TITLE": "Softing Secure Integration Server Cleartext Transmission of Sensitive Information"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Secure Integration Server",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "V1.22"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Softing"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Pedro Ribeiro and Radek Domanski, working with Trend Micro Zero Day Initiative, reported these vulnerabilities to Softing and CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Softing Secure Integration Server V1.22 is vulnerable to authentication bypass via a machine-in-the-middle attack. The default the administration interface is accessible via plaintext HTTP protocol, facilitating the attack. The HTTP request may contain the session cookie in the request, which may be captured for use in authenticating to the server."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-319: Cleartext Transmission of Sensitive Information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04",
              "refsource": "CONFIRM",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04"
            },
            {
              "name": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-5.html",
              "refsource": "CONFIRM",
              "url": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-5.html"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Softing released new versions to address these vulnerabilities and notified known users of the releases. Users are advised to update to the new versions:\nSofting Secure Integration Server V1.30 \n\nThe latest software packages can be downloaded from the Softing website. \n\nSofting recommends the following mitigations and workarounds: \nChange the admin password or create a new user with administrative rights and delete the default admin user. \nConfigure the Windows firewall to block network requests to IP port 9000. \nDisable the HTTP Server in NGINX configuration of the Softing Secure Integration Server, only using the HTTPS server. \nFor more details on these vulnerabilities and mitigations, users should see SYT-2022-5 on the Softing security website."
          }
        ],
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-2338",
    "datePublished": "2022-08-17T20:15:03.000Z",
    "dateReserved": "2022-07-06T00:00:00.000Z",
    "dateUpdated": "2025-04-16T16:12:59.993Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-2005 (GCVE-0-2022-2005)

Vulnerability from cvelistv5 – Published: 2022-08-31 15:33 – Updated: 2025-04-16 16:11
VLAI
Title
AutomationDirect C-more EA9 HMI Cleartext Transmission
Summary
AutomationDirect C-more EA9 HTTP webserver uses an insecure mechanism to transport credentials from client to web server, which may allow an attacker to obtain the login credentials and login as a valid user. This issue affects: AutomationDirect C-more EA9 EA9-T6CL versions prior to 6.73; EA9-T6CL-R versions prior to 6.73; EA9-T7CL versions prior to 6.73; EA9-T7CL-R versions prior to 6.73; EA9-T8CL versions prior to 6.73; EA9-T10CL versions prior to 6.73; EA9-T10WCL versions prior to 6.73; EA9-T12CL versions prior to 6.73; EA9-T15CL versions prior to 6.73; EA9-RHMI versions prior to 6.73; EA9-PGMSW versions prior to 6.73;
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
Impacted products
Vendor Product Version
AutomationDirect C-more EA9 Affected: EA9-T6CL , < 6.73 (custom)
Affected: EA9-T6CL-R , < 6.73 (custom)
Affected: EA9-T7CL , < 6.73 (custom)
Affected: EA9-T7CL-R , < 6.73 (custom)
Affected: EA9-T8CL , < 6.73 (custom)
Affected: EA9-T10CL , < 6.73 (custom)
Affected: EA9-T10WCL , < 6.73 (custom)
Affected: EA9-T12CL , < 6.73 (custom)
Affected: EA9-T15CL , < 6.73 (custom)
Affected: EA9-RHMI , < 6.73 (custom)
Affected: EA9-PGMSW , < 6.73 (custom)
Create a notification for this product.
Date Public
2022-06-16 00:00
Credits
Sam Hanson of Dragos reported this vulnerability to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:24:43.894Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-01"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-2005",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T15:54:38.875988Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T16:11:43.495Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "C-more EA9",
          "vendor": "AutomationDirect",
          "versions": [
            {
              "lessThan": "6.73",
              "status": "affected",
              "version": "EA9-T6CL",
              "versionType": "custom"
            },
            {
              "lessThan": "6.73",
              "status": "affected",
              "version": "EA9-T6CL-R",
              "versionType": "custom"
            },
            {
              "lessThan": "6.73",
              "status": "affected",
              "version": "EA9-T7CL",
              "versionType": "custom"
            },
            {
              "lessThan": "6.73",
              "status": "affected",
              "version": "EA9-T7CL-R",
              "versionType": "custom"
            },
            {
              "lessThan": "6.73",
              "status": "affected",
              "version": "EA9-T8CL",
              "versionType": "custom"
            },
            {
              "lessThan": "6.73",
              "status": "affected",
              "version": "EA9-T10CL",
              "versionType": "custom"
            },
            {
              "lessThan": "6.73",
              "status": "affected",
              "version": "EA9-T10WCL",
              "versionType": "custom"
            },
            {
              "lessThan": "6.73",
              "status": "affected",
              "version": "EA9-T12CL",
              "versionType": "custom"
            },
            {
              "lessThan": "6.73",
              "status": "affected",
              "version": "EA9-T15CL",
              "versionType": "custom"
            },
            {
              "lessThan": "6.73",
              "status": "affected",
              "version": "EA9-RHMI",
              "versionType": "custom"
            },
            {
              "lessThan": "6.73",
              "status": "affected",
              "version": "EA9-PGMSW",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Sam Hanson of Dragos reported this vulnerability to CISA."
        }
      ],
      "datePublic": "2022-06-16T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "AutomationDirect C-more EA9 HTTP webserver uses an insecure mechanism to transport credentials from client to web server, which may allow an attacker to obtain the login credentials and login as a valid user. This issue affects: AutomationDirect C-more EA9 EA9-T6CL versions prior to 6.73; EA9-T6CL-R versions prior to 6.73; EA9-T7CL versions prior to 6.73; EA9-T7CL-R versions prior to 6.73; EA9-T8CL versions prior to 6.73; EA9-T10CL versions prior to 6.73; EA9-T10WCL versions prior to 6.73; EA9-T12CL versions prior to 6.73; EA9-T15CL versions prior to 6.73; EA9-RHMI versions prior to 6.73; EA9-PGMSW versions prior to 6.73;"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319 Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-31T15:33:03.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "AutomationDirect recommends users upgrade to firmware Version 6.73 or later, which supports TLS security options for the webserver.\n\nWhile automation networks and systems have built-in password protection schemes, this is only one step in securing the affected systems. Automation control system networks must incorporate data protection and security measures at least as robust as a typical business computer system. AutomationDirect recommends users of PLCs, HMI products, and other SCADA system products perform independent network security analysis to determine the proper level of security required for the application.\n\nAutomationDirect has identified the following mitigations for instances where systems cannot be upgraded to Version 6.73 or later:\n\nThe Webserver feature can be disabled on the HMI using the programming software.\nPlace the HMI panel behind a VPN: Access to and from critical control system assets in the modern environment is usually LAN based, but still should be considered remote if the operator is traversing across different networks. virtual private networking (VPN) is often considered the best approach in securing trans-network communication."
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "AutomationDirect C-more EA9 HMI Cleartext Transmission",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2022-06-16T17:00:00.000Z",
          "ID": "CVE-2022-2005",
          "STATE": "PUBLIC",
          "TITLE": "AutomationDirect C-more EA9 HMI Cleartext Transmission"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "C-more EA9",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "EA9-T6CL",
                            "version_value": "6.73"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "EA9-T6CL-R",
                            "version_value": "6.73"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "EA9-T7CL",
                            "version_value": "6.73"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "EA9-T7CL-R",
                            "version_value": "6.73"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "EA9-T8CL",
                            "version_value": "6.73"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "EA9-T10CL",
                            "version_value": "6.73"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "EA9-T10WCL",
                            "version_value": "6.73"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "EA9-T12CL",
                            "version_value": "6.73"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "EA9-T15CL",
                            "version_value": "6.73"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "EA9-RHMI",
                            "version_value": "6.73"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "EA9-PGMSW",
                            "version_value": "6.73"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "AutomationDirect"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Sam Hanson of Dragos reported this vulnerability to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "AutomationDirect C-more EA9 HTTP webserver uses an insecure mechanism to transport credentials from client to web server, which may allow an attacker to obtain the login credentials and login as a valid user. This issue affects: AutomationDirect C-more EA9 EA9-T6CL versions prior to 6.73; EA9-T6CL-R versions prior to 6.73; EA9-T7CL versions prior to 6.73; EA9-T7CL-R versions prior to 6.73; EA9-T8CL versions prior to 6.73; EA9-T10CL versions prior to 6.73; EA9-T10WCL versions prior to 6.73; EA9-T12CL versions prior to 6.73; EA9-T15CL versions prior to 6.73; EA9-RHMI versions prior to 6.73; EA9-PGMSW versions prior to 6.73;"
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-319 Cleartext Transmission of Sensitive Information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-01",
              "refsource": "CONFIRM",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-01"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "AutomationDirect recommends users upgrade to firmware Version 6.73 or later, which supports TLS security options for the webserver.\n\nWhile automation networks and systems have built-in password protection schemes, this is only one step in securing the affected systems. Automation control system networks must incorporate data protection and security measures at least as robust as a typical business computer system. AutomationDirect recommends users of PLCs, HMI products, and other SCADA system products perform independent network security analysis to determine the proper level of security required for the application.\n\nAutomationDirect has identified the following mitigations for instances where systems cannot be upgraded to Version 6.73 or later:\n\nThe Webserver feature can be disabled on the HMI using the programming software.\nPlace the HMI panel behind a VPN: Access to and from critical control system assets in the modern environment is usually LAN based, but still should be considered remote if the operator is traversing across different networks. virtual private networking (VPN) is often considered the best approach in securing trans-network communication."
          }
        ],
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-2005",
    "datePublished": "2022-08-31T15:33:03.273Z",
    "dateReserved": "2022-06-06T00:00:00.000Z",
    "dateUpdated": "2025-04-16T16:11:43.495Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-2003 (GCVE-0-2022-2003)

Vulnerability from cvelistv5 – Published: 2022-08-31 15:59 – Updated: 2025-04-16 17:49
VLAI
Title
AutomationDirect DirectLOGIC with Serial Communication Cleartext Transmission
Summary
AutomationDirect DirectLOGIC is vulnerable to a specifically crafted serial message to the CPU serial port that will cause the PLC to respond with the PLC password in cleartext. This could allow an attacker to access and make unauthorized changes. This issue affects: AutomationDirect DirectLOGIC D0-06 series CPUs D0-06DD1 versions prior to 2.72; D0-06DD2 versions prior to 2.72; D0-06DR versions prior to 2.72; D0-06DA versions prior to 2.72; D0-06AR versions prior to 2.72; D0-06AA versions prior to 2.72; D0-06DD1-D versions prior to 2.72; D0-06DD2-D versions prior to 2.72; D0-06DR-D versions prior to 2.72;
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
Impacted products
Vendor Product Version
AutomationDirect DirectLOGIC D0-06 series CPUs Affected: D0-06DD1 , < 2.72 (custom)
Affected: D0-06DD2 , < 2.72 (custom)
Affected: D0-06DR , < 2.72 (custom)
Affected: D0-06DA , < 2.72 (custom)
Affected: D0-06AR , < 2.72 (custom)
Affected: D0-06AA , < 2.72 (custom)
Affected: D0-06DD1-D , < 2.72 (custom)
Affected: D0-06DD2-D , < 2.72 (custom)
Affected: D0-06DR-D , < 2.72 (custom)
Create a notification for this product.
Date Public
2022-06-16 00:00
Credits
Sam Hanson of Dragos reported this vulnerability to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:24:44.055Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-02"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-03"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-2003",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T17:27:42.525536Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T17:49:17.171Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DirectLOGIC D0-06 series CPUs",
          "vendor": "AutomationDirect",
          "versions": [
            {
              "lessThan": "2.72",
              "status": "affected",
              "version": "D0-06DD1",
              "versionType": "custom"
            },
            {
              "lessThan": "2.72",
              "status": "affected",
              "version": "D0-06DD2",
              "versionType": "custom"
            },
            {
              "lessThan": "2.72",
              "status": "affected",
              "version": "D0-06DR",
              "versionType": "custom"
            },
            {
              "lessThan": "2.72",
              "status": "affected",
              "version": "D0-06DA",
              "versionType": "custom"
            },
            {
              "lessThan": "2.72",
              "status": "affected",
              "version": "D0-06AR",
              "versionType": "custom"
            },
            {
              "lessThan": "2.72",
              "status": "affected",
              "version": "D0-06AA",
              "versionType": "custom"
            },
            {
              "lessThan": "2.72",
              "status": "affected",
              "version": "D0-06DD1-D",
              "versionType": "custom"
            },
            {
              "lessThan": "2.72",
              "status": "affected",
              "version": "D0-06DD2-D",
              "versionType": "custom"
            },
            {
              "lessThan": "2.72",
              "status": "affected",
              "version": "D0-06DR-D",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Sam Hanson of Dragos reported this vulnerability to CISA."
        }
      ],
      "datePublic": "2022-06-16T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "AutomationDirect DirectLOGIC is vulnerable to a specifically crafted serial message to the CPU serial port that will cause the PLC to respond with the PLC password in cleartext. This could allow an attacker to access and make unauthorized changes. This issue affects: AutomationDirect DirectLOGIC D0-06 series CPUs D0-06DD1 versions prior to 2.72; D0-06DD2 versions prior to 2.72; D0-06DR versions prior to 2.72; D0-06DA versions prior to 2.72; D0-06AR versions prior to 2.72; D0-06AA versions prior to 2.72; D0-06DD1-D versions prior to 2.72; D0-06DD2-D versions prior to 2.72; D0-06DR-D versions prior to 2.72;"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 7.7,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319 Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-31T15:59:33.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-02"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-03"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "AutomationDirect recommends users upgrade to firmware Version 2.72 or later, which will no longer respond with the password when requested with the specially crafted message.\n\nAdditional mitigation for brute force password access has also been added. Three incorrect password entries will result in a 3-hour lock out of password entry. Power cycle will allow subsequent password attempts.\n\nWhile automation networks and systems have built-in password protection schemes, this is only one step in securing the affected systems. Automation control system networks must incorporate data protection and security measures at least as robust as a typical business computer system. AutomationDirect recommends users of PLCs, HMI products, and other SCADA system products perform independent network security analysis to determine the proper level of security required for the application.\n\nAutomationDirect has identified the specific mitigation actions listed below:\n\nSecure physical access.\nIsolate and air gap networks when possible.\nConsider some of the AutomationDirect newer PLC families."
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "AutomationDirect DirectLOGIC with Serial Communication Cleartext Transmission",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2022-06-16T17:00:00.000Z",
          "ID": "CVE-2022-2003",
          "STATE": "PUBLIC",
          "TITLE": "AutomationDirect DirectLOGIC with Serial Communication Cleartext Transmission"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "DirectLOGIC D0-06 series CPUs",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "D0-06DD1",
                            "version_value": "2.72"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "D0-06DD2",
                            "version_value": "2.72"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "D0-06DR",
                            "version_value": "2.72"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "D0-06DA",
                            "version_value": "2.72"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "D0-06AR",
                            "version_value": "2.72"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "D0-06AA",
                            "version_value": "2.72"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "D0-06DD1-D",
                            "version_value": "2.72"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "D0-06DD2-D",
                            "version_value": "2.72"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "D0-06DR-D",
                            "version_value": "2.72"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "AutomationDirect"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Sam Hanson of Dragos reported this vulnerability to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "AutomationDirect DirectLOGIC is vulnerable to a specifically crafted serial message to the CPU serial port that will cause the PLC to respond with the PLC password in cleartext. This could allow an attacker to access and make unauthorized changes. This issue affects: AutomationDirect DirectLOGIC D0-06 series CPUs D0-06DD1 versions prior to 2.72; D0-06DD2 versions prior to 2.72; D0-06DR versions prior to 2.72; D0-06DA versions prior to 2.72; D0-06AR versions prior to 2.72; D0-06AA versions prior to 2.72; D0-06DD1-D versions prior to 2.72; D0-06DD2-D versions prior to 2.72; D0-06DR-D versions prior to 2.72;"
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 7.7,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-319 Cleartext Transmission of Sensitive Information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-02",
              "refsource": "CONFIRM",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-02"
            },
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-03",
              "refsource": "CONFIRM",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-03"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "AutomationDirect recommends users upgrade to firmware Version 2.72 or later, which will no longer respond with the password when requested with the specially crafted message.\n\nAdditional mitigation for brute force password access has also been added. Three incorrect password entries will result in a 3-hour lock out of password entry. Power cycle will allow subsequent password attempts.\n\nWhile automation networks and systems have built-in password protection schemes, this is only one step in securing the affected systems. Automation control system networks must incorporate data protection and security measures at least as robust as a typical business computer system. AutomationDirect recommends users of PLCs, HMI products, and other SCADA system products perform independent network security analysis to determine the proper level of security required for the application.\n\nAutomationDirect has identified the specific mitigation actions listed below:\n\nSecure physical access.\nIsolate and air gap networks when possible.\nConsider some of the AutomationDirect newer PLC families."
          }
        ],
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-2003",
    "datePublished": "2022-08-31T15:59:33.369Z",
    "dateReserved": "2022-06-06T00:00:00.000Z",
    "dateUpdated": "2025-04-16T17:49:17.171Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-1524 (GCVE-0-2022-1524)

Vulnerability from cvelistv5 – Published: 2022-06-24 15:00 – Updated: 2025-04-16 17:52
VLAI
Title
3.2.5 CLEARTEXT TRANSMISSION OF SENSITIVE INFORMATION CWE-319
Summary
LRM version 2.4 and lower does not implement TLS encryption. A malicious actor can MITM attack sensitive data in-transit, including credentials.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
Date Public
2022-06-02 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:10:03.321Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-153-02"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-1524",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T17:28:35.654447Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T17:52:17.725Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "NextSeq 550Dx",
          "vendor": "Illumina",
          "versions": [
            {
              "status": "affected",
              "version": "LRM Versions 1.3 to 3.1"
            }
          ]
        },
        {
          "product": "MiSeq Dx",
          "vendor": "Illumina",
          "versions": [
            {
              "status": "affected",
              "version": "LRM Versions 1.3 to 3.1"
            }
          ]
        },
        {
          "product": "NextSeq 500 Instrument",
          "vendor": "Illumina",
          "versions": [
            {
              "status": "affected",
              "version": "LRM Versions 1.3 to 3.1"
            }
          ]
        },
        {
          "product": "NextSeq 550 Instrument",
          "vendor": "Illumina",
          "versions": [
            {
              "status": "affected",
              "version": "LRM Versions 1.3 to 3.1"
            }
          ]
        },
        {
          "product": "MiSeq Instrument",
          "vendor": "Illumina",
          "versions": [
            {
              "status": "affected",
              "version": "LRM Versions 1.3 to 3.1"
            }
          ]
        },
        {
          "product": "iSeq 100 Instrument",
          "vendor": "Illumina",
          "versions": [
            {
              "status": "affected",
              "version": "LRM Versions 1.3 to 3.1"
            }
          ]
        },
        {
          "product": "MiniSeq Instrument",
          "vendor": "Illumina",
          "versions": [
            {
              "status": "affected",
              "version": "LRM Versions 1.3 to 3.1"
            }
          ]
        }
      ],
      "datePublic": "2022-06-02T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "LRM version 2.4 and lower does not implement TLS encryption. A malicious actor can MITM attack sensitive data in-transit, including credentials."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.4,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319 Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-24T15:00:16.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-153-02"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "3.2.5    CLEARTEXT TRANSMISSION OF SENSITIVE INFORMATION CWE-319",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "AKA": "",
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "20220602T06:00:00.000000Z",
          "ID": "CVE-2022-1524",
          "STATE": "PUBLIC",
          "TITLE": "3.2.5    CLEARTEXT TRANSMISSION OF SENSITIVE INFORMATION CWE-319"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "NextSeq 550Dx",
                      "version": {
                        "version_data": [
                          {
                            "platform": "",
                            "version_affected": "=",
                            "version_name": "",
                            "version_value": "LRM Versions 1.3 to 3.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Illumina"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "MiSeq Dx",
                      "version": {
                        "version_data": [
                          {
                            "platform": "",
                            "version_affected": "=",
                            "version_name": "",
                            "version_value": "LRM Versions 1.3 to 3.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Illumina"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "NextSeq 500 Instrument",
                      "version": {
                        "version_data": [
                          {
                            "platform": "",
                            "version_affected": "=",
                            "version_name": "",
                            "version_value": "LRM Versions 1.3 to 3.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Illumina"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "NextSeq 550 Instrument",
                      "version": {
                        "version_data": [
                          {
                            "platform": "",
                            "version_affected": "=",
                            "version_name": "",
                            "version_value": "LRM Versions 1.3 to 3.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Illumina"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "MiSeq Instrument",
                      "version": {
                        "version_data": [
                          {
                            "platform": "",
                            "version_affected": "=",
                            "version_name": "",
                            "version_value": "LRM Versions 1.3 to 3.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Illumina"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "iSeq 100 Instrument",
                      "version": {
                        "version_data": [
                          {
                            "platform": "",
                            "version_affected": "=",
                            "version_name": "",
                            "version_value": "LRM Versions 1.3 to 3.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Illumina"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "MiniSeq Instrument",
                      "version": {
                        "version_data": [
                          {
                            "platform": "",
                            "version_affected": "=",
                            "version_name": "",
                            "version_value": "LRM Versions 1.3 to 3.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Illumina"
              }
            ]
          }
        },
        "credit": [],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "LRM version 2.4 and lower does not implement TLS encryption. A malicious actor can MITM attack sensitive data in-transit, including credentials."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.4,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-319 Cleartext Transmission of Sensitive Information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-153-02",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-153-02"
            }
          ]
        },
        "solution": [],
        "source": {
          "advisory": "",
          "defect": [],
          "discovery": "UNKNOWN"
        },
        "work_around": []
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-1524",
    "datePublished": "2022-06-24T15:00:16.330Z",
    "dateReserved": "2022-04-28T00:00:00.000Z",
    "dateUpdated": "2025-04-16T17:52:17.725Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation
Architecture and Design

Before transmitting, encrypt the data using reliable, confidentiality-protecting cryptographic protocols.

Mitigation
Implementation

When using web applications with SSL, use SSL for the entire session from login to logout, not just for the initial login page.

Mitigation
Implementation

When designing hardware platforms, ensure that approved encryption algorithms (such as those recommended by NIST) protect paths from security critical data to trusted user applications.

Mitigation
Testing

Use tools and techniques that require manual (human) analysis, such as penetration testing, threat modeling, and interactive tools that allow the tester to record and modify an active session. These may be more effective than strictly automated techniques. This is especially the case with weaknesses that are related to design and business rules.

Mitigation
Operation

Configure servers to use encrypted channels for communication, which may include SSL or other secure protocols.

CAPEC-102: Session Sidejacking

Session sidejacking takes advantage of an unencrypted communication channel between a victim and target system. The attacker sniffs traffic on a network looking for session tokens in unencrypted traffic. Once a session token is captured, the attacker performs malicious actions by using the stolen token with the targeted application to impersonate the victim. This attack is a specific method of session hijacking, which is exploiting a valid session token to gain unauthorized access to a target system or information. Other methods to perform a session hijacking are session fixation, cross-site scripting, or compromising a user or server machine and stealing the session token.

CAPEC-117: Interception

An adversary monitors data streams to or from the target for information gathering purposes. This attack may be undertaken to solely gather sensitive information or to support a further attack against the target. This attack pattern can involve sniffing network traffic as well as other types of data streams (e.g. radio). The adversary can attempt to initiate the establishment of a data stream or passively observe the communications as they unfold. In all variants of this attack, the adversary is not the intended recipient of the data stream. In contrast to other means of gathering information (e.g., targeting data leaks), the adversary must actively position themself so as to observe explicit data channels (e.g. network traffic) and read the content. However, this attack differs from a Adversary-In-the-Middle (CAPEC-94) attack, as the adversary does not alter the content of the communications nor forward data to the intended recipient.

CAPEC-383: Harvesting Information via API Event Monitoring

An adversary hosts an event within an application framework and then monitors the data exchanged during the course of the event for the purpose of harvesting any important data leaked during the transactions. One example could be harvesting lists of usernames or userIDs for the purpose of sending spam messages to those users. One example of this type of attack involves the adversary creating an event within the sub-application. Assume the adversary hosts a "virtual sale" of rare items. As other users enter the event, the attacker records via AiTM (CAPEC-94) proxy the user_ids and usernames of everyone who attends. The adversary would then be able to spam those users within the application using an automated script.

CAPEC-477: Signature Spoofing by Mixing Signed and Unsigned Content

An attacker exploits the underlying complexity of a data structure that allows for both signed and unsigned content, to cause unsigned data to be processed as though it were signed data.

CAPEC-65: Sniff Application Code

An adversary passively sniffs network communications and captures application code bound for an authorized client. Once obtained, they can use it as-is, or through reverse-engineering glean sensitive information or exploit the trust relationship between the client and server. Such code may belong to a dynamic update to the client, a patch being applied to a client component or any such interaction where the client is authorized to communicate with the server.