Common Weakness Enumeration

CWE-121

Allowed

Stack-based Buffer Overflow

Abstraction: Variant · Status: Draft

A stack-based buffer overflow condition is a condition where the buffer being overwritten is allocated on the stack (i.e., is a local variable or, rarely, a parameter to a function).

5783 vulnerabilities reference this CWE, most recent first.

GHSA-5RMP-977F-X986

Vulnerability from github – Published: 2026-06-13 00:34 – Updated: 2026-06-13 00:34
VLAI
Details

Stack overflow vulnerability in Avast Antivirus when scanning a malformed Office Open XML file may allow Denial-of-Service of the antivirus process.

This issue affects Avast Antivirus, AVG Antivirus, Norton Antivirus, Avast One, and Avast Business Antivirus on Windows, macOS, and Linux for virus definition builds before VPS 25020100.

The affected scanning logic is delivered through a shared Gen Digital virus definition update stream. The same stream feeds the consumer antivirus products listed in this advisory and other Gen Digital products that embed the same engine. Mitigation flows through this update channel; installations at or above the listed build are not vulnerable regardless of which product consumes the stream.

Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2025-7019"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-121"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2026-06-12T22:16:49Z",
    "severity": "MODERATE"
  },
  "details": "Stack overflow vulnerability in Avast Antivirus when scanning a malformed Office Open XML file may allow Denial-of-Service of the antivirus process.\n\nThis issue affects Avast Antivirus, AVG Antivirus, Norton Antivirus, Avast One, and Avast Business Antivirus on Windows, macOS, and Linux for virus definition builds before VPS 25020100.\n\n\n\nThe affected scanning logic is delivered through a shared Gen Digital virus definition update stream. The same stream feeds the consumer antivirus products listed in this advisory and other Gen Digital products that embed the same engine. Mitigation flows through this update channel; installations at or above the listed build are not vulnerable regardless of which product consumes the stream.",
  "id": "GHSA-5rmp-977f-x986",
  "modified": "2026-06-13T00:34:31Z",
  "published": "2026-06-13T00:34:31Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2025-7019"
    },
    {
      "type": "WEB",
      "url": "https://www.gendigital.com/us/en/contact-us/security-advisories"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
      "type": "CVSS_V3"
    }
  ]
}

GHSA-5V2F-93MX-7R24

Vulnerability from github – Published: 2024-03-06 18:30 – Updated: 2024-03-06 18:30
VLAI
Details

A vulnerability in the web-based user interface of Cisco Small Business 100, 300, and 500 Series Wireless APs could allow an authenticated, remote attacker to perform buffer overflow attacks against an affected device. In order to exploit this vulnerability, the attacker must have valid administrative credentials for the device. This vulnerability is due to insufficient validation of user-supplied input. An attacker could exploit this vulnerability by sending a crafted HTTP request to the web-based management interface of an affected device. A successful exploit could allow the attacker to execute arbitrary code as the root user on the underlying operating system.

Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2024-20336"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-121"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2024-03-06T17:15:09Z",
    "severity": "MODERATE"
  },
  "details": "A vulnerability in the web-based user interface of Cisco Small Business 100, 300, and 500 Series Wireless APs could allow an authenticated, remote attacker to perform buffer overflow attacks against an affected device. In order to exploit this vulnerability, the attacker must have valid administrative credentials for the device. This vulnerability is due to insufficient validation of user-supplied input. An attacker could exploit this vulnerability by sending a crafted HTTP request to the web-based management interface of an affected device. A successful exploit could allow the attacker to execute arbitrary code as the root user on the underlying operating system.",
  "id": "GHSA-5v2f-93mx-7r24",
  "modified": "2024-03-06T18:30:37Z",
  "published": "2024-03-06T18:30:37Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2024-20336"
    },
    {
      "type": "WEB",
      "url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-sb-wap-multi-85G83CRB"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N",
      "type": "CVSS_V3"
    }
  ]
}

GHSA-5V3G-553G-MCMP

Vulnerability from github – Published: 2024-03-29 15:30 – Updated: 2024-08-27 21:31
VLAI
Details

Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the time parameter from saveParentControlInfo function.

Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2024-30630"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-121",
      "CWE-125"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2024-03-29T13:15:16Z",
    "severity": "CRITICAL"
  },
  "details": "Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the time parameter from saveParentControlInfo function.",
  "id": "GHSA-5v3g-553g-mcmp",
  "modified": "2024-08-27T21:31:11Z",
  "published": "2024-03-29T15:30:31Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2024-30630"
    },
    {
      "type": "WEB",
      "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/saveParentControlInfo_time.md"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
      "type": "CVSS_V3"
    }
  ]
}

GHSA-5V68-73XH-WCGW

Vulnerability from github – Published: 2024-04-17 00:30 – Updated: 2024-04-26 09:30
VLAI
Details

Vulnerability in the MySQL Server product of Oracle MySQL (component: Server: Optimizer). Supported versions that are affected are 8.0.36 and prior and 8.3.0 and prior. Easily exploitable vulnerability allows high privileged attacker with network access via multiple protocols to compromise MySQL Server. Successful attacks of this vulnerability can result in unauthorized ability to cause a hang or frequently repeatable crash (complete DOS) of MySQL Server. CVSS 3.1 Base Score 4.9 (Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H).

Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2024-20998"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-121"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2024-04-16T22:15:13Z",
    "severity": "MODERATE"
  },
  "details": "Vulnerability in the MySQL Server product of Oracle MySQL (component: Server: Optimizer).  Supported versions that are affected are 8.0.36 and prior and  8.3.0 and prior. Easily exploitable vulnerability allows high privileged attacker with network access via multiple protocols to compromise MySQL Server.  Successful attacks of this vulnerability can result in unauthorized ability to cause a hang or frequently repeatable crash (complete DOS) of MySQL Server. CVSS 3.1 Base Score 4.9 (Availability impacts).  CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H).",
  "id": "GHSA-5v68-73xh-wcgw",
  "modified": "2024-04-26T09:30:33Z",
  "published": "2024-04-17T00:30:54Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2024-20998"
    },
    {
      "type": "WEB",
      "url": "https://security.netapp.com/advisory/ntap-20240426-0013"
    },
    {
      "type": "WEB",
      "url": "https://www.oracle.com/security-alerts/cpuapr2024.html"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
      "type": "CVSS_V3"
    }
  ]
}

GHSA-5VFQ-Q3P7-564Q

Vulnerability from github – Published: 2024-04-17 15:30 – Updated: 2024-08-01 15:31
VLAI
Details

Tenda FH1202 v1.2.0.14(408) firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle function.

Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2024-32302"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-121",
      "CWE-787"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2024-04-17T14:15:09Z",
    "severity": "MODERATE"
  },
  "details": "Tenda FH1202 v1.2.0.14(408) firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle function.",
  "id": "GHSA-5vfq-q3p7-564q",
  "modified": "2024-08-01T15:31:40Z",
  "published": "2024-04-17T15:30:43Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2024-32302"
    },
    {
      "type": "WEB",
      "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1202/fromWizardHandle.md"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
      "type": "CVSS_V3"
    }
  ]
}

GHSA-5VFQ-Q6F3-HH9V

Vulnerability from github – Published: 2026-08-13 00:31 – Updated: 2026-08-13 00:31
VLAI
Details

A data source definition containing an over-length file path setting may cause the MongoDB BI Connector ODBC Driver setup dialog to write outside the bounds of an allocated buffer. The issue stems from an incorrect buffer capacity calculation in the dialog's file and folder selection handling, and is reached only when a user opens the setup dialog for such a data source and initiates a file or folder selection. Depending on build configuration, the result may range from abnormal process termination to, under certain conditions, execution of unintended code in the context of the user running the dialog.

Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2026-19003"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-121"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2026-08-12T22:17:15Z",
    "severity": "HIGH"
  },
  "details": "A data source definition containing an over-length file path setting may cause the MongoDB BI Connector ODBC Driver setup dialog to write outside the bounds of an allocated buffer. The issue stems from an incorrect buffer capacity calculation in the dialog\u0027s file and folder selection handling, and is reached only when a user opens the setup dialog for such a data source and initiates a file or folder selection. Depending on build configuration, the result may range from abnormal process termination to, under certain conditions, execution of unintended code in the context of the user running the dialog.",
  "id": "GHSA-5vfq-q6f3-hh9v",
  "modified": "2026-08-13T00:31:25Z",
  "published": "2026-08-13T00:31:25Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2026-19003"
    },
    {
      "type": "WEB",
      "url": "https://github.com/mongodb/mongo-bi-connector-odbc-driver/releases/tag/v1.4.9"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
      "type": "CVSS_V3"
    },
    {
      "score": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
      "type": "CVSS_V4"
    }
  ]
}

GHSA-5VJ8-JGQJ-77H6

Vulnerability from github – Published: 2026-08-19 18:32 – Updated: 2026-08-19 18:32
VLAI
Details

FFmpeg before commit 9d786e4 contains a stack buffer overflow in the MPEG-PS muxer (libavformat/mpegenc.c). When muxing input with more streams than the muxer's fixed-size stack buffer accommodates, the buffer is overflowed. A crafted input with an excessive number of streams triggers the overflow during MPEG-PS muxing.

Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2026-75142"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-121"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2026-08-19T17:21:12Z",
    "severity": "HIGH"
  },
  "details": "FFmpeg before commit 9d786e4 contains a stack buffer overflow in the MPEG-PS muxer (libavformat/mpegenc.c). When muxing input with more streams than the muxer\u0027s fixed-size stack buffer accommodates, the buffer is overflowed. A crafted input with an excessive number of streams triggers the overflow during MPEG-PS muxing.",
  "id": "GHSA-5vj8-jgqj-77h6",
  "modified": "2026-08-19T18:32:51Z",
  "published": "2026-08-19T18:32:51Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2026-75142"
    },
    {
      "type": "WEB",
      "url": "https://code.ffmpeg.org/FFmpeg/FFmpeg/commit/9d786e4b5e9b8482651928574de33772aeee7be1"
    },
    {
      "type": "WEB",
      "url": "https://code.ffmpeg.org/FFmpeg/FFmpeg/pulls/24087"
    },
    {
      "type": "WEB",
      "url": "https://www.vulncheck.com/advisories/ffmpeg-stack-buffer-overflow-in-mpeg-ps-muxer-via-mpegenc-c"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
      "type": "CVSS_V3"
    },
    {
      "score": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
      "type": "CVSS_V4"
    }
  ]
}

GHSA-5VJV-CQM3-G9M6

Vulnerability from github – Published: 2025-08-25 15:32 – Updated: 2025-11-03 21:34
VLAI
Details

A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master Branch (35a819fa). A specially crafted MFER file can lead to arbitrary code execution. An attacker can provide a malicious file to trigger this vulnerability.This vulnerability manifests on line 8824 of biosig.c on the current master branch (35a819fa), when the Tag is 11:

            else if (tag==11)    //0x0B
            {
                // Fs
                if (len>6) fprintf(stderr,"Warning MFER tag11 incorrect length %i>6\n",len);
                double  fval;
                curPos += ifread(buf,1,len,hdr);
Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2025-54486"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-121"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2025-08-25T14:15:34Z",
    "severity": "CRITICAL"
  },
  "details": "A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master Branch (35a819fa). A specially crafted MFER file can lead to arbitrary code execution. An attacker can provide a malicious file to trigger this vulnerability.This vulnerability manifests on line 8824 of biosig.c on the current master branch (35a819fa), when the Tag is 11:\n\n                else if (tag==11)    //0x0B\n                {\n                    // Fs\n                    if (len\u003e6) fprintf(stderr,\"Warning MFER tag11 incorrect length %i\u003e6\\n\",len);\n                    double  fval;\n                    curPos += ifread(buf,1,len,hdr);",
  "id": "GHSA-5vjv-cqm3-g9m6",
  "modified": "2025-11-03T21:34:23Z",
  "published": "2025-08-25T15:32:01Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2025-54486"
    },
    {
      "type": "WEB",
      "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2025-2234"
    },
    {
      "type": "WEB",
      "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2025-2234"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
      "type": "CVSS_V3"
    }
  ]
}

GHSA-5VMQ-VJG2-R39R

Vulnerability from github – Published: 2026-09-08 18:32 – Updated: 2026-09-08 18:32
VLAI
Details

Stack-based buffer overflow in Windows Win32K allows an authorized attacker to elevate privileges over a network.

Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2026-69301"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-121"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2026-09-08T18:18:45Z",
    "severity": "HIGH"
  },
  "details": "Stack-based buffer overflow in Windows Win32K allows an authorized attacker to elevate privileges over a network.",
  "id": "GHSA-5vmq-vjg2-r39r",
  "modified": "2026-09-08T18:32:21Z",
  "published": "2026-09-08T18:32:21Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2026-69301"
    },
    {
      "type": "WEB",
      "url": "https://msrc.microsoft.com/update-guide/vulnerability/CVE-2026-69301"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
      "type": "CVSS_V3"
    }
  ]
}

GHSA-5VPG-RF76-M7C5

Vulnerability from github – Published: 2023-12-07 15:30 – Updated: 2023-12-09 06:30
VLAI
Details

Tenda AX12 V22.03.01.46 was discovered to contain a stack overflow via the list parameter at /goform/SetVirtualServerCfg.

Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2023-49424"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-121",
      "CWE-787"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2023-12-07T14:15:08Z",
    "severity": "CRITICAL"
  },
  "details": "Tenda AX12 V22.03.01.46 was discovered to contain a stack overflow via the list parameter at /goform/SetVirtualServerCfg.",
  "id": "GHSA-5vpg-rf76-m7c5",
  "modified": "2023-12-09T06:30:20Z",
  "published": "2023-12-07T15:30:38Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2023-49424"
    },
    {
      "type": "WEB",
      "url": "https://github.com/ef4tless/vuln/blob/master/iot/AX12/SetVirtualServerCfg.md"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
      "type": "CVSS_V3"
    }
  ]
}

Mitigation MIT-10
Operation Build and Compilation

Strategy: Environment Hardening

  • Use automatic buffer overflow detection mechanisms that are offered by certain compilers or compiler extensions. Examples include: the Microsoft Visual Studio /GS flag, Fedora/Red Hat FORTIFY_SOURCE GCC flag, StackGuard, and ProPolice, which provide various mechanisms including canary-based detection and range/index checking.
  • D3-SFCV (Stack Frame Canary Validation) from D3FEND [REF-1334] discusses canary-based detection in detail.
Mitigation
Architecture and Design

Use an abstraction library to abstract away risky APIs. Not a complete solution.

Mitigation
Implementation

Implement and perform bounds checking on input.

Mitigation
Implementation

Do not use dangerous functions such as gets. Use safer, equivalent functions which check for boundary errors.

Mitigation MIT-11
Operation Build and Compilation

Strategy: Environment Hardening

  • Run or compile the software using features or extensions that randomly arrange the positions of a program's executable and libraries in memory. Because this makes the addresses unpredictable, it can prevent an attacker from reliably jumping to exploitable code.
  • Examples include Address Space Layout Randomization (ASLR) [REF-58] [REF-60] and Position-Independent Executables (PIE) [REF-64]. Imported modules may be similarly realigned if their default memory addresses conflict with other modules, in a process known as "rebasing" (for Windows) and "prelinking" (for Linux) [REF-1332] using randomly generated addresses. ASLR for libraries cannot be used in conjunction with prelink since it would require relocating the libraries at run-time, defeating the whole purpose of prelinking.
  • For more information on these techniques see D3-SAOR (Segment Address Offset Randomization) from D3FEND [REF-1335].

No CAPEC attack patterns related to this CWE.