CVE-2024-1630 (GCVE-0-2024-1630)
Vulnerability from cvelistv5
Published
2024-05-14 16:55
Modified
2024-08-22 17:51
CWE
  • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Summary
Path traversal vulnerability in “getAllFolderContents” function of Common Service Desktop, a GE HealthCare ultrasound device component
Impacted products
Vendor Product Version
GE HealthCare Venue Version: R1
Version: R2
Version: R3   <
Version: R4   <
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T18:48:21.818Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://securityupdate.gehealthcare.com/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:gehealthcare:venue_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "venue_firmware",
            "vendor": "gehealthcare",
            "versions": [
              {
                "status": "affected",
                "version": "r1"
              },
              {
                "status": "affected",
                "version": "r2"
              },
              {
                "lessThanOrEqual": "r3.3",
                "status": "affected",
                "version": "r3",
                "versionType": "custom"
              },
              {
                "lessThanOrEqual": "r4.3",
                "status": "affected",
                "version": "r4",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:gehealthcare:venue_go_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "venue_go_firmware",
            "vendor": "gehealthcare",
            "versions": [
              {
                "status": "affected",
                "version": "r2"
              },
              {
                "lessThanOrEqual": "r3.3",
                "status": "affected",
                "version": "r3",
                "versionType": "custom"
              },
              {
                "lessThanOrEqual": "r4.3",
                "status": "affected",
                "version": "r4",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:gehealthcare:venue_fit_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "venue_fit_firmware",
            "vendor": "gehealthcare",
            "versions": [
              {
                "lessThanOrEqual": "r3.3",
                "status": "affected",
                "version": "r3",
                "versionType": "custom"
              },
              {
                "lessThanOrEqual": "r4.3",
                "status": "affected",
                "version": "r4",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:gehealthcare:logiq_e_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "logiq_e_firmware",
            "vendor": "gehealthcare",
            "versions": [
              {
                "lessThanOrEqual": "r9.1.4",
                "status": "affected",
                "version": "r7",
                "versionType": "custom"
              },
              {
                "lessThanOrEqual": "r10.1.3",
                "status": "affected",
                "version": "r8",
                "versionType": "custom"
              },
              {
                "lessThanOrEqual": "r11.0.3",
                "status": "affected",
                "version": "r9",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:gehealthcare:logiq_he_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "logiq_he_firmware",
            "vendor": "gehealthcare",
            "versions": [
              {
                "lessThanOrEqual": "r9.3.1",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:gehealthcare:vivid_e_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "vivid_e_firmware",
            "vendor": "gehealthcare",
            "versions": [
              {
                "lessThan": "206",
                "status": "affected",
                "version": "e95",
                "versionType": "custom"
              },
              {
                "lessThan": "206",
                "status": "affected",
                "version": "e90",
                "versionType": "custom"
              },
              {
                "lessThan": "206",
                "status": "affected",
                "version": "e80",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:gehealthcare:vivid_t_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "vivid_t_firmware",
            "vendor": "gehealthcare",
            "versions": [
              {
                "lessThan": "206",
                "status": "affected",
                "version": "t8",
                "versionType": "custom"
              },
              {
                "lessThan": "206",
                "status": "affected",
                "version": "t9",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:gehealthcare:vivid_iq_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "vivid_iq_firmware",
            "vendor": "gehealthcare",
            "versions": [
              {
                "lessThan": "206",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:gehealthcare:voluson_expert_16:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "voluson_expert_16",
            "vendor": "gehealthcare",
            "versions": [
              {
                "status": "affected",
                "version": "0"
              },
              {
                "status": "affected",
                "version": "bt24"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:gehealthcare:voluson_expert_18:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "voluson_expert_18",
            "vendor": "gehealthcare",
            "versions": [
              {
                "status": "affected",
                "version": "0"
              },
              {
                "status": "affected",
                "version": "bt24"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:gehealthcare:voluson_expert_22:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "voluson_expert_22",
            "vendor": "gehealthcare",
            "versions": [
              {
                "status": "affected",
                "version": "0"
              },
              {
                "status": "affected",
                "version": "bt24"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:gehealthcare:voluson_swift:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "voluson_swift",
            "vendor": "gehealthcare",
            "versions": [
              {
                "status": "affected",
                "version": "0"
              },
              {
                "status": "affected",
                "version": "bt24"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:gehealthcare:logiq_e10:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "logiq_e10",
            "vendor": "gehealthcare",
            "versions": [
              {
                "lessThan": "r3.2.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:gehealthcare:logiq_e10s:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "logiq_e10s",
            "vendor": "gehealthcare",
            "versions": [
              {
                "lessThan": "r3.2.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:gehealthcare:logiq_fortis:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "logiq_fortis",
            "vendor": "gehealthcare",
            "versions": [
              {
                "lessThan": "r3.2.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-1630",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-14T19:43:01.721848Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-22T17:51:14.776Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Venue",
          "vendor": "GE HealthCare",
          "versions": [
            {
              "status": "affected",
              "version": "R1"
            },
            {
              "status": "affected",
              "version": "R2"
            },
            {
              "lessThanOrEqual": "R3.3",
              "status": "affected",
              "version": "R3",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "R4.3",
              "status": "affected",
              "version": "R4",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Venue Go",
          "vendor": "GE HealthCare",
          "versions": [
            {
              "status": "affected",
              "version": "R2"
            },
            {
              "lessThanOrEqual": "R3.3",
              "status": "affected",
              "version": "R3",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "R4.3",
              "status": "affected",
              "version": "R4",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Venue Fit",
          "vendor": "GE HealthCare",
          "versions": [
            {
              "lessThanOrEqual": "R3.3",
              "status": "affected",
              "version": "R3",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "R4.3",
              "status": "affected",
              "version": "R4",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "LOGIQ e",
          "vendor": "GE HealthCare",
          "versions": [
            {
              "lessThanOrEqual": "R9.1.4",
              "status": "affected",
              "version": "R7",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "R10.1.3",
              "status": "affected",
              "version": "R8",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "R11.0.3",
              "status": "affected",
              "version": "R9",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "LOGIQ He",
          "vendor": "GE HealthCare",
          "versions": [
            {
              "lessThanOrEqual": "R9.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Vivid E",
          "vendor": "GE HealthCare",
          "versions": [
            {
              "lessThan": "206",
              "status": "affected",
              "version": "E95",
              "versionType": "custom"
            },
            {
              "lessThan": "206",
              "status": "affected",
              "version": "E90",
              "versionType": "custom"
            },
            {
              "lessThan": "206",
              "status": "affected",
              "version": "E80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Vivid T",
          "vendor": "GE HealthCare",
          "versions": [
            {
              "lessThan": "206",
              "status": "affected",
              "version": "T8",
              "versionType": "custom"
            },
            {
              "lessThan": "206",
              "status": "affected",
              "version": "T9",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Vivid iq",
          "vendor": "GE HealthCare",
          "versions": [
            {
              "lessThan": "206",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Voluson Expert 16",
          "vendor": "GE HealthCare",
          "versions": [
            {
              "status": "affected",
              "version": "0"
            },
            {
              "status": "affected",
              "version": "BT24"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Voluson Expert 18",
          "vendor": "GE HealthCare",
          "versions": [
            {
              "status": "affected",
              "version": "0"
            },
            {
              "status": "affected",
              "version": "BT24"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Voluson Expert 22",
          "vendor": "GE HealthCare",
          "versions": [
            {
              "status": "affected",
              "version": "0"
            },
            {
              "status": "affected",
              "version": "BT24"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Voluson SWIFT",
          "vendor": "GE HealthCare",
          "versions": [
            {
              "status": "affected",
              "version": "0"
            },
            {
              "status": "affected",
              "version": "BT24"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "LOGIQ E10",
          "vendor": "GE HealthCare",
          "versions": [
            {
              "lessThan": "R3.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "LOGIQ E10s",
          "vendor": "GE HealthCare",
          "versions": [
            {
              "lessThan": "R3.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "LOGIQ Fortis",
          "vendor": "GE HealthCare",
          "versions": [
            {
              "lessThan": "R3.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Andrea Palanca and Gabriele Quagliarella of Nozomi Networks"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Path traversal vulnerability in \u201cgetAllFolderContents\u201d function of Common Service Desktop, a GE HealthCare ultrasound device component"
            }
          ],
          "value": "Path traversal vulnerability in \u201cgetAllFolderContents\u201d function of Common Service Desktop, a GE HealthCare ultrasound device component"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-126",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-126 Path Traversal"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 7.7,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-22",
              "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-14T16:55:56.853Z",
        "orgId": "171caf72-b841-4e04-a68e-93493aff2b94",
        "shortName": "GEHC"
      },
      "references": [
        {
          "url": "https://securityupdate.gehealthcare.com/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Path traversal vulnerability in \u201cgetAllFolderContents\u201d function of Common Service Desktop, a GE HealthCare ultrasound device component",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "171caf72-b841-4e04-a68e-93493aff2b94",
    "assignerShortName": "GEHC",
    "cveId": "CVE-2024-1630",
    "datePublished": "2024-05-14T16:55:56.853Z",
    "dateReserved": "2024-02-19T15:28:03.794Z",
    "dateUpdated": "2024-08-22T17:51:14.776Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-1630\",\"sourceIdentifier\":\"171caf72-b841-4e04-a68e-93493aff2b94\",\"published\":\"2024-05-14T17:15:31.047\",\"lastModified\":\"2024-11-21T08:50:57.613\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Path traversal vulnerability in \u201cgetAllFolderContents\u201d function of Common Service Desktop, a GE HealthCare ultrasound device component\"},{\"lang\":\"es\",\"value\":\"Vulnerabilidad de Path Traversal en la funci\u00f3n \u201cgetAllFolderContents\u201d de Common Service Desktop, un componente del dispositivo de ultrasonido de GE HealthCare\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"171caf72-b841-4e04-a68e-93493aff2b94\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N\",\"baseScore\":7.7,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.5,\"impactScore\":5.2}]},\"weaknesses\":[{\"source\":\"171caf72-b841-4e04-a68e-93493aff2b94\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-22\"}]}],\"references\":[{\"url\":\"https://securityupdate.gehealthcare.com/\",\"source\":\"171caf72-b841-4e04-a68e-93493aff2b94\"},{\"url\":\"https://securityupdate.gehealthcare.com/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://securityupdate.gehealthcare.com/\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-01T18:48:21.818Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-1630\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-05-14T19:43:01.721848Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:o:gehealthcare:venue_firmware:*:*:*:*:*:*:*:*\"], \"vendor\": \"gehealthcare\", \"product\": \"venue_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"r1\"}, {\"status\": \"affected\", \"version\": \"r2\"}, {\"status\": \"affected\", \"version\": \"r3\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"r3.3\"}, {\"status\": \"affected\", \"version\": \"r4\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"r4.3\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:o:gehealthcare:venue_go_firmware:*:*:*:*:*:*:*:*\"], \"vendor\": \"gehealthcare\", \"product\": \"venue_go_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"r2\"}, {\"status\": \"affected\", \"version\": \"r3\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"r3.3\"}, {\"status\": \"affected\", \"version\": \"r4\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"r4.3\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:o:gehealthcare:venue_fit_firmware:*:*:*:*:*:*:*:*\"], \"vendor\": \"gehealthcare\", \"product\": \"venue_fit_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"r3\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"r3.3\"}, {\"status\": \"affected\", \"version\": \"r4\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"r4.3\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:o:gehealthcare:logiq_e_firmware:*:*:*:*:*:*:*:*\"], \"vendor\": \"gehealthcare\", \"product\": \"logiq_e_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"r7\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"r9.1.4\"}, {\"status\": \"affected\", \"version\": \"r8\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"r10.1.3\"}, {\"status\": \"affected\", \"version\": \"r9\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"r11.0.3\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:o:gehealthcare:logiq_he_firmware:*:*:*:*:*:*:*:*\"], \"vendor\": \"gehealthcare\", \"product\": \"logiq_he_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"r9.3.1\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:o:gehealthcare:vivid_e_firmware:*:*:*:*:*:*:*:*\"], \"vendor\": \"gehealthcare\", \"product\": \"vivid_e_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"e95\", \"lessThan\": \"206\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"e90\", \"lessThan\": \"206\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"e80\", \"lessThan\": \"206\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:o:gehealthcare:vivid_t_firmware:*:*:*:*:*:*:*:*\"], \"vendor\": \"gehealthcare\", \"product\": \"vivid_t_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"t8\", \"lessThan\": \"206\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"t9\", \"lessThan\": \"206\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:o:gehealthcare:vivid_iq_firmware:*:*:*:*:*:*:*:*\"], \"vendor\": \"gehealthcare\", \"product\": \"vivid_iq_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"206\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:a:gehealthcare:voluson_expert_16:*:*:*:*:*:*:*:*\"], \"vendor\": \"gehealthcare\", \"product\": \"voluson_expert_16\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\"}, {\"status\": \"affected\", \"version\": \"bt24\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:a:gehealthcare:voluson_expert_18:*:*:*:*:*:*:*:*\"], \"vendor\": \"gehealthcare\", \"product\": \"voluson_expert_18\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\"}, {\"status\": \"affected\", \"version\": \"bt24\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:a:gehealthcare:voluson_expert_22:*:*:*:*:*:*:*:*\"], \"vendor\": \"gehealthcare\", \"product\": \"voluson_expert_22\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\"}, {\"status\": \"affected\", \"version\": \"bt24\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:a:gehealthcare:voluson_swift:*:*:*:*:*:*:*:*\"], \"vendor\": \"gehealthcare\", \"product\": \"voluson_swift\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\"}, {\"status\": \"affected\", \"version\": \"bt24\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:a:gehealthcare:logiq_e10:*:*:*:*:*:*:*:*\"], \"vendor\": \"gehealthcare\", \"product\": \"logiq_e10\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"r3.2.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:a:gehealthcare:logiq_e10s:*:*:*:*:*:*:*:*\"], \"vendor\": \"gehealthcare\", \"product\": \"logiq_e10s\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"r3.2.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:a:gehealthcare:logiq_fortis:*:*:*:*:*:*:*:*\"], \"vendor\": \"gehealthcare\", \"product\": \"logiq_fortis\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"r3.2.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-08-22T16:07:13.366Z\"}}], \"cna\": {\"title\": \"Path traversal vulnerability in \\u201cgetAllFolderContents\\u201d function of Common Service Desktop, a GE HealthCare ultrasound device component\", \"source\": {\"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Andrea Palanca and Gabriele Quagliarella of Nozomi Networks\"}], \"impacts\": [{\"capecId\": \"CAPEC-126\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-126 Path Traversal\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.7, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"GE HealthCare\", \"product\": \"Venue\", \"versions\": [{\"status\": \"affected\", \"version\": \"R1\"}, {\"status\": \"affected\", \"version\": \"R2\"}, {\"status\": \"affected\", \"version\": \"R3\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"R3.3\"}, {\"status\": \"affected\", \"version\": \"R4\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"R4.3\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"GE HealthCare\", \"product\": \"Venue Go\", \"versions\": [{\"status\": \"affected\", \"version\": \"R2\"}, {\"status\": \"affected\", \"version\": \"R3\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"R3.3\"}, {\"status\": \"affected\", \"version\": \"R4\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"R4.3\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"GE HealthCare\", \"product\": \"Venue Fit\", \"versions\": [{\"status\": \"affected\", \"version\": \"R3\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"R3.3\"}, {\"status\": \"affected\", \"version\": \"R4\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"R4.3\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"GE HealthCare\", \"product\": \"LOGIQ e\", \"versions\": [{\"status\": \"affected\", \"version\": \"R7\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"R9.1.4\"}, {\"status\": \"affected\", \"version\": \"R8\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"R10.1.3\"}, {\"status\": \"affected\", \"version\": \"R9\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"R11.0.3\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"GE HealthCare\", \"product\": \"LOGIQ He\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"R9.3.1\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"GE HealthCare\", \"product\": \"Vivid E\", \"versions\": [{\"status\": \"affected\", \"version\": \"E95\", \"lessThan\": \"206\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"E90\", \"lessThan\": \"206\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"E80\", \"lessThan\": \"206\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"GE HealthCare\", \"product\": \"Vivid T\", \"versions\": [{\"status\": \"affected\", \"version\": \"T8\", \"lessThan\": \"206\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"T9\", \"lessThan\": \"206\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"GE HealthCare\", \"product\": \"Vivid iq\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"206\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"GE HealthCare\", \"product\": \"Voluson Expert 16\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\"}, {\"status\": \"affected\", \"version\": \"BT24\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"GE HealthCare\", \"product\": \"Voluson Expert 18\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\"}, {\"status\": \"affected\", \"version\": \"BT24\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"GE HealthCare\", \"product\": \"Voluson Expert 22\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\"}, {\"status\": \"affected\", \"version\": \"BT24\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"GE HealthCare\", \"product\": \"Voluson SWIFT\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\"}, {\"status\": \"affected\", \"version\": \"BT24\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"GE HealthCare\", \"product\": \"LOGIQ E10\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"R3.2.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"GE HealthCare\", \"product\": \"LOGIQ E10s\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"R3.2.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"GE HealthCare\", \"product\": \"LOGIQ Fortis\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"R3.2.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://securityupdate.gehealthcare.com/\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Path traversal vulnerability in \\u201cgetAllFolderContents\\u201d function of Common Service Desktop, a GE HealthCare ultrasound device component\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Path traversal vulnerability in \\u201cgetAllFolderContents\\u201d function of Common Service Desktop, a GE HealthCare ultrasound device component\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-22\", \"description\": \"CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"171caf72-b841-4e04-a68e-93493aff2b94\", \"shortName\": \"GEHC\", \"dateUpdated\": \"2024-05-14T16:55:56.853Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2024-1630\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-22T17:51:14.776Z\", \"dateReserved\": \"2024-02-19T15:28:03.794Z\", \"assignerOrgId\": \"171caf72-b841-4e04-a68e-93493aff2b94\", \"datePublished\": \"2024-05-14T16:55:56.853Z\", \"assignerShortName\": \"GEHC\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…