var-202411-0914
Vulnerability from variot
A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0018), Tecnomatix Plant Simulation V2404 (All versions < V2404.0007). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-24244). Siemens' Tecnomatix Plant Simulation Exists in a vulnerability related to the use of freed memory.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of WRL files. The issue results from the lack of validating the existence of an object prior to performing operations on the object. Siemens Tecnomatix Plant Simulation is an industrial control device of Siemens, Germany. It uses the function of discrete event simulation to analyze and optimize production volume, thereby improving the performance of manufacturing systems
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202411-0914", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "tecnomatix plant simulation", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2302.0018" }, { "model": "tecnomatix plant simulation", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2404.0007" }, { "model": "tecnomatix plant simulation", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "2404.0" }, { "model": "tecnomatix plant simulation", "scope": "eq", "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": "2404.0 that\u0027s all 2404.0007" }, { "model": "tecnomatix plant simulation", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "tecnomatix plant simulation", "scope": "eq", "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": "2302.0018" }, { "model": "tecnomatix plant simulation", "scope": "eq", "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "tecnomatix plant simulation", "scope": null, "trust": 0.7, "vendor": "siemens", "version": null }, { "model": "tecnomatix plant simulation", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v2302\u003c2302.0018" }, { "model": "tecnomatix plant simulation", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v2404\u003c2404.0007" } ], "sources": [ { "db": "ZDI", "id": "ZDI-24-1520" }, { "db": "CNVD", "id": "CNVD-2024-45996" }, { "db": "JVNDB", "id": "JVNDB-2024-013138" }, { "db": "NVD", "id": "CVE-2024-52568" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Rocco Calvi (@TecR0c) with TecSecurity", "sources": [ { "db": "ZDI", "id": "ZDI-24-1520" } ], "trust": 0.7 }, "cve": "CVE-2024-52568", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 3.9, "id": "CNVD-2024-45996", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "productcert@siemens.com", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "id": "CVE-2024-52568", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "OTHER", "availabilityImpact": "High", "baseScore": 7.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2024-013138", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "ZDI", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "id": "CVE-2024-52568", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 0.7, "userInteraction": "REQUIRED", "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "productcert@siemens.com", "id": "CVE-2024-52568", "trust": 1.0, "value": "High" }, { "author": "OTHER", "id": "JVNDB-2024-013138", "trust": 0.8, "value": "High" }, { "author": "ZDI", "id": "CVE-2024-52568", "trust": 0.7, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2024-45996", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "ZDI", "id": "ZDI-24-1520" }, { "db": "CNVD", "id": "CNVD-2024-45996" }, { "db": "JVNDB", "id": "JVNDB-2024-013138" }, { "db": "NVD", "id": "CVE-2024-52568" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0018), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0007). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files. \r\nAn attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-24244). Siemens\u0027 Tecnomatix Plant Simulation Exists in a vulnerability related to the use of freed memory.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of WRL files. The issue results from the lack of validating the existence of an object prior to performing operations on the object. Siemens Tecnomatix Plant Simulation is an industrial control device of Siemens, Germany. It uses the function of discrete event simulation to analyze and optimize production volume, thereby improving the performance of manufacturing systems", "sources": [ { "db": "NVD", "id": "CVE-2024-52568" }, { "db": "JVNDB", "id": "JVNDB-2024-013138" }, { "db": "ZDI", "id": "ZDI-24-1520" }, { "db": "CNVD", "id": "CNVD-2024-45996" } ], "trust": 2.79 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2024-52568", "trust": 3.9 }, { "db": "SIEMENS", "id": "SSA-824503", "trust": 2.4 }, { "db": "JVN", "id": "JVNVU96191615", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2024-013138", "trust": 0.8 }, { "db": "ZDI_CAN", "id": "ZDI-CAN-24244", "trust": 0.7 }, { "db": "ZDI", "id": "ZDI-24-1520", "trust": 0.7 }, { "db": "CNVD", "id": "CNVD-2024-45996", "trust": 0.6 } ], "sources": [ { "db": "ZDI", "id": "ZDI-24-1520" }, { "db": "CNVD", "id": "CNVD-2024-45996" }, { "db": "JVNDB", "id": "JVNDB-2024-013138" }, { "db": "NVD", "id": "CVE-2024-52568" } ] }, "id": "VAR-202411-0914", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-45996" } ], "trust": 0.87226892 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-45996" } ] }, "last_update_date": "2024-11-29T19:43:02.424000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Siemens has issued an update to correct this vulnerability.", "trust": 0.7, "url": "https://cert-portal.siemens.com/productcert/html/ssa-824503.html" }, { "title": "Patch for Siemens Tecnomatix Plant Simulation Memory Misreference Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/628951" } ], "sources": [ { "db": "ZDI", "id": "ZDI-24-1520" }, { "db": "CNVD", "id": "CNVD-2024-45996" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-416", "trust": 1.0 }, { "problemtype": "Use of freed memory (CWE-416) [ others ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-013138" }, { "db": "NVD", "id": "CVE-2024-52568" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.1, "url": "https://cert-portal.siemens.com/productcert/html/ssa-824503.html" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu96191615/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2024-52568" } ], "sources": [ { "db": "ZDI", "id": "ZDI-24-1520" }, { "db": "CNVD", "id": "CNVD-2024-45996" }, { "db": "JVNDB", "id": "JVNDB-2024-013138" }, { "db": "NVD", "id": "CVE-2024-52568" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "ZDI", "id": "ZDI-24-1520" }, { "db": "CNVD", "id": "CNVD-2024-45996" }, { "db": "JVNDB", "id": "JVNDB-2024-013138" }, { "db": "NVD", "id": "CVE-2024-52568" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-11-19T00:00:00", "db": "ZDI", "id": "ZDI-24-1520" }, { "date": "2024-11-28T00:00:00", "db": "CNVD", "id": "CNVD-2024-45996" }, { "date": "2024-11-21T00:00:00", "db": "JVNDB", "id": "JVNDB-2024-013138" }, { "date": "2024-11-18T16:15:27.773000", "db": "NVD", "id": "CVE-2024-52568" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-11-19T00:00:00", "db": "ZDI", "id": "ZDI-24-1520" }, { "date": "2024-11-26T00:00:00", "db": "CNVD", "id": "CNVD-2024-45996" }, { "date": "2024-11-21T00:50:00", "db": "JVNDB", "id": "JVNDB-2024-013138" }, { "date": "2024-11-20T14:32:58.637000", "db": "NVD", "id": "CVE-2024-52568" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens\u0027 \u00a0Tecnomatix\u00a0Plant\u00a0Simulation\u00a0 Vulnerability in using free memory in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-013138" } ], "trust": 0.8 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.