var-202411-0014
Vulnerability from variot
A vulnerability has been found in Tenda AC15 15.03.05.19 and classified as critical. This vulnerability affects the function SetDlnaCfg of the file /goform/SetDlnaCfg. The manipulation of the argument scanList leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. Shenzhen Tenda Technology Co.,Ltd. of AC15 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Remote attackers can use this vulnerability to submit special requests, which can cause the application to crash or execute arbitrary code in the context of the application
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202411-0014", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac15", "scope": "eq", "trust": 1.6, "vendor": "tenda", "version": "15.03.05.19" }, { "model": "ac15", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac15 firmware 15.03.05.19" }, { "model": "ac15", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac15", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-44507" }, { "db": "JVNDB", "id": "JVNDB-2024-011972" }, { "db": "NVD", "id": "CVE-2024-10661" } ] }, "cve": "CVE-2024-10661", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "cna@vuldb.com", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "CVE-2024-10661", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 1.0, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "Single", "author": "OTHER", "availabilityImpact": "Complete", "baseScore": 9.0, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "JVNDB-2024-011972", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "CNVD-2024-44507", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "cna@vuldb.com", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2024-10661", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2024-011972", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "cna@vuldb.com", "id": "CVE-2024-10661", "trust": 1.0, "value": "High" }, { "author": "nvd@nist.gov", "id": "CVE-2024-10661", "trust": 1.0, "value": "HIGH" }, { "author": "OTHER", "id": "JVNDB-2024-011972", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2024-44507", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-44507" }, { "db": "JVNDB", "id": "JVNDB-2024-011972" }, { "db": "NVD", "id": "CVE-2024-10661" }, { "db": "NVD", "id": "CVE-2024-10661" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been found in Tenda AC15 15.03.05.19 and classified as critical. This vulnerability affects the function SetDlnaCfg of the file /goform/SetDlnaCfg. The manipulation of the argument scanList leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. Shenzhen Tenda Technology Co.,Ltd. of AC15 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Remote attackers can use this vulnerability to submit special requests, which can cause the application to crash or execute arbitrary code in the context of the application", "sources": [ { "db": "NVD", "id": "CVE-2024-10661" }, { "db": "JVNDB", "id": "JVNDB-2024-011972" }, { "db": "CNVD", "id": "CNVD-2024-44507" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2024-10661", "trust": 3.2 }, { "db": "VULDB", "id": "282676", "trust": 1.8 }, { "db": "JVNDB", "id": "JVNDB-2024-011972", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2024-44507", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-44507" }, { "db": "JVNDB", "id": "JVNDB-2024-011972" }, { "db": "NVD", "id": "CVE-2024-10661" } ] }, "id": "VAR-202411-0014", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-44507" } ], "trust": 1.00636206 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-44507" } ] }, "last_update_date": "2024-11-13T23:04:58.801000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "CWE-121", "trust": 1.0 }, { "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]", "trust": 0.8 }, { "problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-011972" }, { "db": "NVD", "id": "CVE-2024-10661" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://github.com/theraz0r/iot-mycve/blob/main/tenda_ac15_stackflow_formdlnaserver/tenda_ac15_stackflow_formdlnaserver.md" }, { "trust": 1.8, "url": "https://vuldb.com/?id.282676" }, { "trust": 1.8, "url": "https://vuldb.com/?submit.434932" }, { "trust": 1.8, "url": "https://www.tenda.com.cn/" }, { "trust": 1.0, "url": "https://vuldb.com/?ctiid.282676" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2024-10661" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-44507" }, { "db": "JVNDB", "id": "JVNDB-2024-011972" }, { "db": "NVD", "id": "CVE-2024-10661" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-44507" }, { "db": "JVNDB", "id": "JVNDB-2024-011972" }, { "db": "NVD", "id": "CVE-2024-10661" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-11-07T00:00:00", "db": "CNVD", "id": "CNVD-2024-44507" }, { "date": "2024-11-06T00:00:00", "db": "JVNDB", "id": "JVNDB-2024-011972" }, { "date": "2024-11-01T16:15:07.430000", "db": "NVD", "id": "CVE-2024-10661" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-11-12T00:00:00", "db": "CNVD", "id": "CNVD-2024-44507" }, { "date": "2024-11-06T01:00:00", "db": "JVNDB", "id": "JVNDB-2024-011972" }, { "date": "2024-11-05T14:30:37.787000", "db": "NVD", "id": "CVE-2024-10661" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC15\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-011972" } ], "trust": 0.8 } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.