A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V2.0). The affected application does not properly handle cacheable HTTP responses in the web service. This could allow an attacker to read and modify data stored in the local cache. Siemens' sinec traffic analyzer Exists in unspecified vulnerabilities.Information may be obtained and information may be tampered with. SINEC Traffic Analyzer is an on-premises application that monitors PNIO (PROFINET IO) communications between controllers and IO devices
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", affected_products: { "@id": "https://www.variotdbs.pl/ref/affected_products", }, configurations: { "@id": "https://www.variotdbs.pl/ref/configurations", }, credits: { "@id": "https://www.variotdbs.pl/ref/credits", }, cvss: { "@id": "https://www.variotdbs.pl/ref/cvss/", }, description: { "@id": "https://www.variotdbs.pl/ref/description/", }, exploit_availability: { "@id": "https://www.variotdbs.pl/ref/exploit_availability/", }, external_ids: { "@id": "https://www.variotdbs.pl/ref/external_ids/", }, iot: { "@id": "https://www.variotdbs.pl/ref/iot/", }, iot_taxonomy: { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/", }, patch: { "@id": "https://www.variotdbs.pl/ref/patch/", }, problemtype_data: { "@id": "https://www.variotdbs.pl/ref/problemtype_data/", }, references: { "@id": "https://www.variotdbs.pl/ref/references/", }, sources: { "@id": "https://www.variotdbs.pl/ref/sources/", }, sources_release_date: { "@id": "https://www.variotdbs.pl/ref/sources_release_date/", }, sources_update_date: { "@id": "https://www.variotdbs.pl/ref/sources_update_date/", }, threat_type: { "@id": "https://www.variotdbs.pl/ref/threat_type/", }, title: { "@id": "https://www.variotdbs.pl/ref/title/", }, type: { "@id": "https://www.variotdbs.pl/ref/type/", }, }, "@id": "https://www.variotdbs.pl/vuln/VAR-202408-0058", affected_products: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", data: { "@container": "@list", }, sources: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", }, "@id": "https://www.variotdbs.pl/ref/sources", }, }, data: [ { model: "sinec traffic analyzer", scope: "lt", trust: 1.6, vendor: "siemens", version: "2.0", }, { model: "sinec traffic analyzer", scope: null, trust: 0.8, vendor: "シーメンス", version: null, }, { model: "sinec traffic analyzer", scope: "eq", trust: 0.8, vendor: "シーメンス", version: null, }, { model: "sinec traffic analyzer", scope: "eq", trust: 0.8, vendor: "シーメンス", version: "2.0", }, ], sources: [ { db: "CNVD", id: "CNVD-2024-35431", }, { db: "JVNDB", id: "JVNDB-2024-005782", }, { db: "NVD", id: "CVE-2024-41906", }, ], }, cve: "CVE-2024-41906", cvss: { "@context": { cvssV2: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#", }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2", }, cvssV3: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#", }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/", }, severity: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#", }, "@id": "https://www.variotdbs.pl/ref/cvss/severity", }, sources: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", }, "@id": "https://www.variotdbs.pl/ref/sources", }, }, data: [ { cvssV2: [ { accessComplexity: "HIGH", accessVector: "NETWORK", authentication: "NONE", author: "CNVD", availabilityImpact: "NONE", baseScore: 4, confidentialityImpact: "PARTIAL", exploitabilityScore: 4.9, id: "CNVD-2024-35431", impactScore: 4.9, integrityImpact: "PARTIAL", severity: "MEDIUM", trust: 0.6, vectorString: "AV:N/AC:H/Au:N/C:P/I:P/A:N", version: "2.0", }, ], cvssV3: [ { attackComplexity: "LOW", attackVector: "NETWORK", author: "nvd@nist.gov", availabilityImpact: "NONE", baseScore: 6.5, baseSeverity: "MEDIUM", confidentialityImpact: "LOW", exploitabilityScore: 3.9, id: "CVE-2024-41906", impactScore: 2.5, integrityImpact: "LOW", privilegesRequired: "NONE", scope: "UNCHANGED", trust: 1, userInteraction: "NONE", vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N", version: "3.1", }, { attackComplexity: "HIGH", attackVector: "NETWORK", author: "productcert@siemens.com", availabilityImpact: "NONE", baseScore: 4.8, baseSeverity: "MEDIUM", confidentialityImpact: "LOW", exploitabilityScore: 2.2, id: "CVE-2024-41906", impactScore: 2.5, integrityImpact: "LOW", privilegesRequired: "NONE", scope: "UNCHANGED", trust: 1, userInteraction: "NONE", vectorString: "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N", version: "3.1", }, { attackComplexity: "Low", attackVector: "Network", author: "NVD", availabilityImpact: "None", baseScore: 6.5, baseSeverity: "Medium", confidentialityImpact: "Low", exploitabilityScore: null, id: "CVE-2024-41906", impactScore: null, integrityImpact: "Low", privilegesRequired: "None", scope: "Unchanged", trust: 0.8, userInteraction: "None", vectorString: "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N", version: "3.0", }, ], severity: [ { author: "nvd@nist.gov", id: "CVE-2024-41906", trust: 1, value: "MEDIUM", }, { author: "productcert@siemens.com", id: "CVE-2024-41906", trust: 1, value: "Medium", }, { author: "NVD", id: "CVE-2024-41906", trust: 0.8, value: "Medium", }, { author: "CNVD", id: "CNVD-2024-35431", trust: 0.6, value: "MEDIUM", }, ], }, ], sources: [ { db: "CNVD", id: "CNVD-2024-35431", }, { db: "JVNDB", id: "JVNDB-2024-005782", }, { db: "NVD", id: "CVE-2024-41906", }, { db: "NVD", id: "CVE-2024-41906", }, ], }, description: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", sources: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", }, }, }, data: "A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V2.0). The affected application does not properly handle cacheable HTTP responses in the web service. This could allow an attacker to read and modify data stored in the local cache. Siemens' sinec traffic analyzer Exists in unspecified vulnerabilities.Information may be obtained and information may be tampered with. SINEC Traffic Analyzer is an on-premises application that monitors PNIO (PROFINET IO) communications between controllers and IO devices", sources: [ { db: "NVD", id: "CVE-2024-41906", }, { db: "JVNDB", id: "JVNDB-2024-005782", }, { db: "CNVD", id: "CNVD-2024-35431", }, ], trust: 2.16, }, external_ids: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", data: { "@container": "@list", }, sources: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", }, }, }, data: [ { db: "NVD", id: "CVE-2024-41906", trust: 3.2, }, { db: "SIEMENS", id: "SSA-716317", trust: 2.4, }, { db: "ICS CERT", id: "ICSA-24-228-04", trust: 0.8, }, { db: "JVN", id: "JVNVU99084687", trust: 0.8, }, { db: "JVNDB", id: "JVNDB-2024-005782", trust: 0.8, }, { db: "CNVD", id: "CNVD-2024-35431", trust: 0.6, }, ], sources: [ { db: "CNVD", id: "CNVD-2024-35431", }, { db: "JVNDB", id: "JVNDB-2024-005782", }, { db: "NVD", id: "CVE-2024-41906", }, ], }, id: "VAR-202408-0058", iot: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", sources: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", }, }, }, data: true, sources: [ { db: "CNVD", id: "CNVD-2024-35431", }, ], trust: 0.06, }, iot_taxonomy: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", data: { "@container": "@list", }, sources: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", }, }, }, data: [ { category: [ "ICS", ], sub_category: null, trust: 0.6, }, ], sources: [ { db: "CNVD", id: "CNVD-2024-35431", }, ], }, last_update_date: "2024-08-24T20:49:01.199000Z", patch: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", data: { "@container": "@list", }, sources: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", }, }, }, data: [ { title: "Patch for Siemens SINEC Traffic Analyzer Information Disclosure Vulnerability", trust: 0.6, url: "https://www.cnvd.org.cn/patchInfo/show/576936", }, ], sources: [ { db: "CNVD", id: "CNVD-2024-35431", }, ], }, problemtype_data: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", sources: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", }, }, }, data: [ { problemtype: "CWE-524", trust: 1, }, { problemtype: "NVD-CWE-Other", trust: 1, }, { problemtype: "others (CWE-Other) [NVD evaluation ]", trust: 0.8, }, ], sources: [ { db: "JVNDB", id: "JVNDB-2024-005782", }, { db: "NVD", id: "CVE-2024-41906", }, ], }, references: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", data: { "@container": "@list", }, sources: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", }, }, }, data: [ { trust: 2.4, url: "https://cert-portal.siemens.com/productcert/html/ssa-716317.html", }, { trust: 0.8, url: "https://jvn.jp/vu/jvnvu99084687/", }, { trust: 0.8, url: "https://nvd.nist.gov/vuln/detail/cve-2024-41906", }, { trust: 0.8, url: "https://www.cisa.gov/news-events/ics-advisories/icsa-24-228-04", }, ], sources: [ { db: "CNVD", id: "CNVD-2024-35431", }, { db: "JVNDB", id: "JVNDB-2024-005782", }, { db: "NVD", id: "CVE-2024-41906", }, ], }, sources: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", data: { "@container": "@list", }, }, data: [ { db: "CNVD", id: "CNVD-2024-35431", }, { db: "JVNDB", id: "JVNDB-2024-005782", }, { db: "NVD", id: "CVE-2024-41906", }, ], }, sources_release_date: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", data: { "@container": "@list", }, }, data: [ { date: "2024-08-14T00:00:00", db: "CNVD", id: "CNVD-2024-35431", }, { date: "2024-08-20T00:00:00", db: "JVNDB", id: "JVNDB-2024-005782", }, { date: "2024-08-13T08:15:13.560000", db: "NVD", id: "CVE-2024-41906", }, ], }, sources_update_date: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", data: { "@container": "@list", }, }, data: [ { date: "2024-08-14T00:00:00", db: "CNVD", id: "CNVD-2024-35431", }, { date: "2024-08-20T03:32:00", db: "JVNDB", id: "JVNDB-2024-005782", }, { date: "2024-08-14T18:04:32.100000", db: "NVD", id: "CVE-2024-41906", }, ], }, title: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", sources: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", }, }, }, data: "Siemens' sinec traffic analyzer Vulnerability in", sources: [ { db: "JVNDB", id: "JVNDB-2024-005782", }, ], trust: 0.8, }, }
Log in or create an account to share your comment.
Security Advisory comment format.
This schema specifies the format of a comment related to a security advisory.
Title of the comment
Description of the comment
Loading…
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.