A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V2.0). The affected application do not properly enforce restriction of excessive authentication attempts. This could allow an unauthenticated attacker to conduct brute force attacks against legitimate user credentials or keys. Siemens' sinec traffic analyzer Is vulnerable to improper restrictions on excessive authentication attempts.Information may be obtained. SINEC Traffic Analyzer is an on-premises application that monitors PNIO (PROFINET IO) communications between controllers and IO devices
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202408-0054", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "sinec traffic analyzer", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "2.0" }, { "model": "sinec traffic analyzer", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinec traffic analyzer", "scope": "eq", "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": "2.0" }, { "model": "sinec traffic analyzer", "scope": "eq", "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-35433" }, { "db": "JVNDB", "id": "JVNDB-2024-005914" }, { "db": "NVD", "id": "CVE-2024-41904" } ] }, "cve": "CVE-2024-41904", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 7.8, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2024-35433", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2024-41904", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2024-41904", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2024-41904", "trust": 1.0, "value": "HIGH" }, { "author": "productcert@siemens.com", "id": "CVE-2024-41904", "trust": 1.0, "value": "High" }, { "author": "NVD", "id": "CVE-2024-41904", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2024-35433", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-35433" }, { "db": "JVNDB", "id": "JVNDB-2024-005914" }, { "db": "NVD", "id": "CVE-2024-41904" }, { "db": "NVD", "id": "CVE-2024-41904" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions \u003c V2.0). The affected application do not properly enforce restriction of excessive authentication attempts. This could allow an unauthenticated attacker to conduct brute force attacks against legitimate user credentials or keys. Siemens\u0027 sinec traffic analyzer Is vulnerable to improper restrictions on excessive authentication attempts.Information may be obtained. SINEC Traffic Analyzer is an on-premises application that monitors PNIO (PROFINET IO) communications between controllers and IO devices", "sources": [ { "db": "NVD", "id": "CVE-2024-41904" }, { "db": "JVNDB", "id": "JVNDB-2024-005914" }, { "db": "CNVD", "id": "CNVD-2024-35433" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2024-41904", "trust": 3.2 }, { "db": "SIEMENS", "id": "SSA-716317", "trust": 2.4 }, { "db": "ICS CERT", "id": "ICSA-24-228-04", "trust": 0.8 }, { "db": "JVN", "id": "JVNVU99084687", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2024-005914", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2024-35433", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-35433" }, { "db": "JVNDB", "id": "JVNDB-2024-005914" }, { "db": "NVD", "id": "CVE-2024-41904" } ] }, "id": "VAR-202408-0054", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-35433" } ], "trust": 0.06 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-35433" } ] }, "last_update_date": "2024-08-24T20:29:02.779000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Siemens SINEC Traffic Analyzer Logic Flaw Vulnerability (CNVD-2024-35433)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/576926" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-35433" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-307", "trust": 1.0 }, { "problemtype": "Inappropriate limitation of excessive authentication attempts (CWE-307) [ others ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-005914" }, { "db": "NVD", "id": "CVE-2024-41904" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://cert-portal.siemens.com/productcert/html/ssa-716317.html" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu99084687/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2024-41904" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-228-04" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-35433" }, { "db": "JVNDB", "id": "JVNDB-2024-005914" }, { "db": "NVD", "id": "CVE-2024-41904" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-35433" }, { "db": "JVNDB", "id": "JVNDB-2024-005914" }, { "db": "NVD", "id": "CVE-2024-41904" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-08-14T00:00:00", "db": "CNVD", "id": "CNVD-2024-35433" }, { "date": "2024-08-21T00:00:00", "db": "JVNDB", "id": "JVNDB-2024-005914" }, { "date": "2024-08-13T08:15:13.003000", "db": "NVD", "id": "CVE-2024-41904" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-08-14T00:00:00", "db": "CNVD", "id": "CNVD-2024-35433" }, { "date": "2024-08-21T02:32:00", "db": "JVNDB", "id": "JVNDB-2024-005914" }, { "date": "2024-08-14T18:39:32.883000", "db": "NVD", "id": "CVE-2024-41904" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens\u0027 \u00a0sinec\u00a0traffic\u00a0analyzer\u00a0 Vulnerability in improperly limiting excessive authentication attempts in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-005914" } ], "trust": 0.8 } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.