A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.5), SIMATIC Energy Manager PRO (All versions < V7.5), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMIT V10 (All versions), SIMIT V11 (All versions < V11.1). Unified Automation .NET based OPC UA Server SDK before 3.2.2 used in Siemens products are affected by a similar vulnerability as documented in CVE-2023-27321 for the OPC Foundation UA .NET Standard implementation. A successful attack may lead to high load situation and memory exhaustion, and may block the server. SIMATIC Energy Manager provides users with a scalable, non-industry-specific energy data management system. SIMATIC IPC DiagBase diagnostic software identifies any potential faults on SIMATIC industrial computers at an early stage and helps to avoid or reduce system downtime. SIMATIC IPC DiagMonitor monitors, reports, visualizes and records the system status of SIMATIC industrial computers. It communicates with other systems and reacts when events occur. SIMIT Simluation Platform allows simulation of plant settings to predict faults in the early planning stage
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202407-0374", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic ipc diagmonitor", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic ipc diagbase", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic energy manager basic", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v7.5" }, { "model": "simatic energy manager pro", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v7.5" }, { "model": "simit", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v10" }, { "model": "simit", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v11\u003cv11.1" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-31238" } ] }, "cve": "CVE-2023-52891", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2024-31238", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "productcert@siemens.com", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2023-52891", "impactScore": 1.4, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" } ], "severity": [ { "author": "productcert@siemens.com", "id": "CVE-2023-52891", "trust": 1.0, "value": "MEDIUM" }, { "author": "CNVD", "id": "CNVD-2024-31238", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-31238" }, { "db": "NVD", "id": "CVE-2023-52891" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions \u003c V7.5), SIMATIC Energy Manager PRO (All versions \u003c V7.5), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMIT V10 (All versions), SIMIT V11 (All versions \u003c V11.1). Unified Automation .NET based OPC UA Server SDK before 3.2.2 used in Siemens products are affected by a similar vulnerability as documented in CVE-2023-27321 for the OPC Foundation UA .NET Standard implementation. A successful attack may lead to high load situation and memory exhaustion, and may block the server. SIMATIC Energy Manager provides users with a scalable, non-industry-specific energy data management system. SIMATIC IPC DiagBase diagnostic software identifies any potential faults on SIMATIC industrial computers at an early stage and helps to avoid or reduce system downtime. SIMATIC IPC DiagMonitor monitors, reports, visualizes and records the system status of SIMATIC industrial computers. It communicates with other systems and reacts when events occur. SIMIT Simluation Platform allows simulation of plant settings to predict faults in the early planning stage", "sources": [ { "db": "NVD", "id": "CVE-2023-52891" }, { "db": "CNVD", "id": "CNVD-2024-31238" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "SIEMENS", "id": "SSA-088132", "trust": 1.6 }, { "db": "NVD", "id": "CVE-2023-52891", "trust": 1.6 }, { "db": "CNVD", "id": "CNVD-2024-31238", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-31238" }, { "db": "NVD", "id": "CVE-2023-52891" } ] }, "id": "VAR-202407-0374", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-31238" } ], "trust": 1.2089285775 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-31238" } ] }, "last_update_date": "2024-08-14T14:01:08.148000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Siemens Industrial Products OPC UA Server Denial of Service Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/567721" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-31238" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-1325", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2023-52891" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://cert-portal.siemens.com/productcert/html/ssa-088132.html" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-31238" }, { "db": "NVD", "id": "CVE-2023-52891" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-31238" }, { "db": "NVD", "id": "CVE-2023-52891" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-07-10T00:00:00", "db": "CNVD", "id": "CNVD-2024-31238" }, { "date": "2024-07-09T12:15:11.263000", "db": "NVD", "id": "CVE-2023-52891" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-07-10T00:00:00", "db": "CNVD", "id": "CNVD-2024-31238" }, { "date": "2024-07-09T18:19:14.047000", "db": "NVD", "id": "CVE-2023-52891" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens Industrial Products OPC UA Server Denial of Service Vulnerability", "sources": [ { "db": "CNVD", "id": "CNVD-2024-31238" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.