var-202312-1440
Vulnerability from variot
TOTOlink EX1800T v9.1.0cu.2112_B20220316 is vulnerable to unauthorized arbitrary command execution in the setRebootScheCfg interface of the cstecgi .cgi. TOTOLINK of ex1800t Firmware contains a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK EX1800T is a Wi-Fi range extender from China's TOTOLINK Electronics
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202312-1440", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ex1800t", "scope": "eq", "trust": 1.0, "vendor": "totolink", "version": "9.1.0cu.2112_b20220316" }, { "model": "ex1800t", "scope": "eq", "trust": 0.8, "vendor": "totolink", "version": null }, { "model": "ex1800t", "scope": null, "trust": 0.8, "vendor": "totolink", "version": null }, { "model": "ex1800t", "scope": "eq", "trust": 0.8, "vendor": "totolink", "version": "ex1800t firmware 9.1.0cu.2112 b20220316" }, { "model": "ex1800t v9.1.0cu.2112 b20220316", "scope": null, "trust": 0.6, "vendor": "totolink", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-27559" }, { "db": "JVNDB", "id": "JVNDB-2023-023774" }, { "db": "NVD", "id": "CVE-2023-51016" } ] }, "cve": "CVE-2023-51016", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2024-27559", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-51016", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-51016", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-51016", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2023-51016", "trust": 0.8, "value": "Critical" }, { "author": "CNVD", "id": "CNVD-2024-27559", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-27559" }, { "db": "JVNDB", "id": "JVNDB-2023-023774" }, { "db": "NVD", "id": "CVE-2023-51016" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "TOTOlink EX1800T v9.1.0cu.2112_B20220316 is vulnerable to unauthorized arbitrary command execution in the setRebootScheCfg interface of the cstecgi .cgi. TOTOLINK of ex1800t Firmware contains a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK EX1800T is a Wi-Fi range extender from China\u0027s TOTOLINK Electronics", "sources": [ { "db": "NVD", "id": "CVE-2023-51016" }, { "db": "JVNDB", "id": "JVNDB-2023-023774" }, { "db": "CNVD", "id": "CNVD-2024-27559" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-51016", "trust": 3.2 }, { "db": "JVNDB", "id": "JVNDB-2023-023774", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2024-27559", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-27559" }, { "db": "JVNDB", "id": "JVNDB-2023-023774" }, { "db": "NVD", "id": "CVE-2023-51016" } ] }, "id": "VAR-202312-1440", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-27559" } ], "trust": 0.06 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-27559" } ] }, "last_update_date": "2024-08-14T15:20:46.512000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-023774" }, { "db": "NVD", "id": "CVE-2023-51016" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://815yang.github.io/2023/12/10/ex1800t/totolink%20ex1800t_v9.1.0cu.2112_b20220316%28setrebootschecfg%29/" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-51016" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-27559" }, { "db": "JVNDB", "id": "JVNDB-2023-023774" }, { "db": "NVD", "id": "CVE-2023-51016" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-27559" }, { "db": "JVNDB", "id": "JVNDB-2023-023774" }, { "db": "NVD", "id": "CVE-2023-51016" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-06-18T00:00:00", "db": "CNVD", "id": "CNVD-2024-27559" }, { "date": "2024-01-29T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-023774" }, { "date": "2023-12-22T19:15:09.493000", "db": "NVD", "id": "CVE-2023-51016" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-06-18T00:00:00", "db": "CNVD", "id": "CNVD-2024-27559" }, { "date": "2024-01-29T07:35:00", "db": "JVNDB", "id": "JVNDB-2023-023774" }, { "date": "2023-12-27T21:07:25.007000", "db": "NVD", "id": "CVE-2023-51016" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "TOTOLINK\u00a0 of \u00a0ex1800t\u00a0 Command injection vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-023774" } ], "trust": 0.8 } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.