var-202310-0197
Vulnerability from variot
A vulnerability has been identified in SINEMA Server V14 (All versions). The affected application improperly sanitizes certain SNMP configuration data retrieved from monitored devices. An attacker with access to a monitored device could perform a stored cross-site scripting (XSS) attack that may lead to arbitrary code execution with SYSTEM privileges on the application server. (ZDI-CAN-19823). Siemens' SINEMA Server Exists in a cross-site scripting vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens SINEMA Server. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the processing of SNMP sysLocation OID. The issue results from the lack of proper validation of user-supplied data, which can lead to the injection of an arbitrary script. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Siemens SINEMA Server is a software developed by the German Siemens company specifically for industrial applications. It enables you to fully visualize and monitor your network
{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202310-0197",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "sinema server",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "14.0"
},
{
"model": "sinema server",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "sinema server",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "sinema server",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": "14.0"
},
{
"model": "sinema server",
"scope": null,
"trust": 0.7,
"vendor": "siemens",
"version": null
},
{
"model": "sinema server",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v14"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-1600"
},
{
"db": "CNVD",
"id": "CNVD-2023-75578"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-015417"
},
{
"db": "NVD",
"id": "CVE-2023-35796"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Andreas Finstad",
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-1600"
}
],
"trust": 0.7
},
"cve": "CVE-2023-35796",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "HIGH",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.6,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 4.9,
"id": "CNVD-2023-75578",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:H/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.0,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.3,
"id": "CVE-2023-35796",
"impactScore": 6.0,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"author": "productcert@siemens.com",
"availabilityImpact": "HIGH",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.6,
"id": "CVE-2023-35796",
"impactScore": 6.0,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.0,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-35796",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Changed",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"author": "ZDI",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.6,
"id": "CVE-2023-35796",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 0.7,
"userInteraction": "REQUIRED",
"vectorString": "AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-35796",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "productcert@siemens.com",
"id": "CVE-2023-35796",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2023-35796",
"trust": 0.8,
"value": "Critical"
},
{
"author": "ZDI",
"id": "CVE-2023-35796",
"trust": 0.7,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2023-75578",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-1600"
},
{
"db": "CNVD",
"id": "CNVD-2023-75578"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-015417"
},
{
"db": "NVD",
"id": "CVE-2023-35796"
},
{
"db": "NVD",
"id": "CVE-2023-35796"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in SINEMA Server V14 (All versions). The affected application improperly sanitizes certain SNMP configuration data retrieved from monitored devices. An attacker with access to a monitored device could perform a stored cross-site scripting (XSS) attack that may lead to arbitrary code execution with `SYSTEM` privileges on the application server. (ZDI-CAN-19823). Siemens\u0027 SINEMA Server Exists in a cross-site scripting vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens SINEMA Server. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the processing of SNMP sysLocation OID. The issue results from the lack of proper validation of user-supplied data, which can lead to the injection of an arbitrary script. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Siemens SINEMA Server is a software developed by the German Siemens company specifically for industrial applications. It enables you to fully visualize and monitor your network",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-35796"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-015417"
},
{
"db": "ZDI",
"id": "ZDI-23-1600"
},
{
"db": "CNVD",
"id": "CNVD-2023-75578"
},
{
"db": "VULMON",
"id": "CVE-2023-35796"
}
],
"trust": 2.88
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-35796",
"trust": 4.0
},
{
"db": "SIEMENS",
"id": "SSA-594373",
"trust": 1.9
},
{
"db": "JVN",
"id": "JVNVU98753493",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2023-015417",
"trust": 0.8
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-19823",
"trust": 0.7
},
{
"db": "ZDI",
"id": "ZDI-23-1600",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2023-75578",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-35796",
"trust": 0.1
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-1600"
},
{
"db": "CNVD",
"id": "CNVD-2023-75578"
},
{
"db": "VULMON",
"id": "CVE-2023-35796"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-015417"
},
{
"db": "NVD",
"id": "CVE-2023-35796"
}
]
},
"id": "VAR-202310-0197",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-75578"
}
],
"trust": 1.1207219
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-75578"
}
]
},
"last_update_date": "2024-08-14T13:19:44.083000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Siemens has issued an update to correct this vulnerability.",
"trust": 0.7,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-594373.html"
},
{
"title": "Patch for Siemens SINEMA Server V14 cross-site scripting vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/466701"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-1600"
},
{
"db": "CNVD",
"id": "CNVD-2023-75578"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-79",
"trust": 1.0
},
{
"problemtype": "Cross-site scripting (CWE-79) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-015417"
},
{
"db": "NVD",
"id": "CVE-2023-35796"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.9,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-594373.pdf"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu98753493/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-35796"
},
{
"trust": 0.7,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-594373.html"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/79.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-1600"
},
{
"db": "VULMON",
"id": "CVE-2023-35796"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-015417"
},
{
"db": "NVD",
"id": "CVE-2023-35796"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "ZDI",
"id": "ZDI-23-1600"
},
{
"db": "CNVD",
"id": "CNVD-2023-75578"
},
{
"db": "VULMON",
"id": "CVE-2023-35796"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-015417"
},
{
"db": "NVD",
"id": "CVE-2023-35796"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-11-14T00:00:00",
"db": "ZDI",
"id": "ZDI-23-1600"
},
{
"date": "2023-10-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-75578"
},
{
"date": "2023-10-10T00:00:00",
"db": "VULMON",
"id": "CVE-2023-35796"
},
{
"date": "2023-12-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-015417"
},
{
"date": "2023-10-10T11:15:11.733000",
"db": "NVD",
"id": "CVE-2023-35796"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-11-14T00:00:00",
"db": "ZDI",
"id": "ZDI-23-1600"
},
{
"date": "2023-10-11T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-75578"
},
{
"date": "2023-10-10T00:00:00",
"db": "VULMON",
"id": "CVE-2023-35796"
},
{
"date": "2023-12-27T05:23:00",
"db": "JVNDB",
"id": "JVNDB-2023-015417"
},
{
"date": "2023-10-24T12:25:01.420000",
"db": "NVD",
"id": "CVE-2023-35796"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens\u0027 \u00a0SINEMA\u00a0Server\u00a0 Cross-site scripting vulnerability in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-015417"
}
],
"trust": 0.8
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.