var-202304-1280
Vulnerability from variot
A CWE-269: Improper Privilege Management vulnerability exists that could cause a local user to perform a denial of service through the console server service that is part of EcoStruxure Control Expert. Affected Products: EcoStruxure Control Expert (V15.1 and above). Schneider Electric of EcoStruxure Control Expert Exists in a permission management vulnerability.Service operation interruption (DoS) It may be in a state. This vulnerability is caused by improper rights management
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202304-1280", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ecostruxure control expert", "scope": "gte", "trust": 1.0, "vendor": "schneider electric", "version": "15.1" }, { "model": "ecostruxure control expert", "scope": "eq", "trust": 0.8, "vendor": "schneider electric", "version": "15.1 that\u0027s all" }, { "model": "ecostruxure control expert", "scope": "eq", "trust": 0.8, "vendor": "schneider electric", "version": null }, { "model": "ecostruxure control expert", "scope": null, "trust": 0.8, "vendor": "schneider electric", "version": null }, { "model": "electric ecostruxure control expert", "scope": "lte", "trust": 0.6, "vendor": "schneider", "version": "\u003c=15.1" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-40177" }, { "db": "JVNDB", "id": "JVNDB-2023-008916" }, { "db": "NVD", "id": "CVE-2023-1548" } ] }, "cve": "CVE-2023-1548", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 4.6, "confidentialityImpact": "NONE", "exploitabilityScore": 3.1, "id": "CNVD-2023-40177", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:L/AC:L/Au:S/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "exploitabilityScore": 1.8, "id": "CVE-2023-1548", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "NVD", "availabilityImpact": "High", "baseScore": 5.5, "baseSeverity": "Medium", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2023-1548", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-1548", "trust": 1.0, "value": "MEDIUM" }, { "author": "cybersecurity@se.com", "id": "CVE-2023-1548", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "CVE-2023-1548", "trust": 0.8, "value": "Medium" }, { "author": "CNVD", "id": "CNVD-2023-40177", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202304-1427", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-40177" }, { "db": "JVNDB", "id": "JVNDB-2023-008916" }, { "db": "CNNVD", "id": "CNNVD-202304-1427" }, { "db": "NVD", "id": "CVE-2023-1548" }, { "db": "NVD", "id": "CVE-2023-1548" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "\nA CWE-269: Improper Privilege Management vulnerability exists that could cause a local user to\nperform a denial of service through the console server service that is part of EcoStruxure Control Expert. Affected Products:\u00a0EcoStruxure Control Expert (V15.1 and above). Schneider Electric of EcoStruxure Control Expert Exists in a permission management vulnerability.Service operation interruption (DoS) It may be in a state. This vulnerability is caused by improper rights management", "sources": [ { "db": "NVD", "id": "CVE-2023-1548" }, { "db": "JVNDB", "id": "JVNDB-2023-008916" }, { "db": "CNVD", "id": "CNVD-2023-40177" }, { "db": "VULMON", "id": "CVE-2023-1548" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-1548", "trust": 3.9 }, { "db": "SCHNEIDER", "id": "SEVD-2023-101-03", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2023-008916", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-40177", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202304-1427", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-1548", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-40177" }, { "db": "VULMON", "id": "CVE-2023-1548" }, { "db": "JVNDB", "id": "JVNDB-2023-008916" }, { "db": "CNNVD", "id": "CNNVD-202304-1427" }, { "db": "NVD", "id": "CVE-2023-1548" } ] }, "id": "VAR-202304-1280", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-40177" } ], "trust": 1.2287037 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-40177" } ] }, "last_update_date": "2024-08-14T14:10:09.383000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Schneider Electric EcoStruxure Control Expert Denial of Service Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/428641" }, { "title": "Schneider Electric EcoStruxure Control Expert Security vulnerabilities", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=235097" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-40177" }, { "db": "CNNVD", "id": "CNNVD-202304-1427" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-269", "trust": 1.0 }, { "problemtype": "Improper authority management (CWE-269) [ others ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-008916" }, { "db": "NVD", "id": "CVE-2023-1548" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://download.schneider-electric.com/files?p_doc_ref=sevd-2023-101-03\u0026p_endoctype=security+and+safety+notice\u0026p_file_name=sevd-2023-101-03.pdf" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-1548" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-1548/" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/269.html" }, { "trust": 0.1, "url": "https://https://download.schneider-electric.com/files?p_doc_ref=sevd-2023-101-03\u0026p_endoctype=security+and+safety+notice\u0026p_file_name=sevd-2023-101-03.pdf" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-40177" }, { "db": "VULMON", "id": "CVE-2023-1548" }, { "db": "JVNDB", "id": "JVNDB-2023-008916" }, { "db": "CNNVD", "id": "CNNVD-202304-1427" }, { "db": "NVD", "id": "CVE-2023-1548" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-40177" }, { "db": "VULMON", "id": "CVE-2023-1548" }, { "db": "JVNDB", "id": "JVNDB-2023-008916" }, { "db": "CNNVD", "id": "CNNVD-202304-1427" }, { "db": "NVD", "id": "CVE-2023-1548" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-05-25T00:00:00", "db": "CNVD", "id": "CNVD-2023-40177" }, { "date": "2023-04-18T00:00:00", "db": "VULMON", "id": "CVE-2023-1548" }, { "date": "2023-12-04T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-008916" }, { "date": "2023-04-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-1427" }, { "date": "2023-04-18T17:15:07.130000", "db": "NVD", "id": "CVE-2023-1548" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-05-24T00:00:00", "db": "CNVD", "id": "CNVD-2023-40177" }, { "date": "2023-04-18T00:00:00", "db": "VULMON", "id": "CVE-2023-1548" }, { "date": "2023-12-04T04:49:00", "db": "JVNDB", "id": "JVNDB-2023-008916" }, { "date": "2023-04-27T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-1427" }, { "date": "2023-05-12T05:15:16.530000", "db": "NVD", "id": "CVE-2023-1548" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-1427" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Schneider\u00a0Electric\u00a0 of \u00a0EcoStruxure\u00a0Control\u00a0Expert\u00a0 Vulnerability in privilege management in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-008916" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-1427" } ], "trust": 0.6 } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.