var-202204-0320
Vulnerability from variot
A vulnerability has been identified in SIMATIC S7-400 CPU 412-1 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416-2 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416F-2 DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 417-4 DP V7 (All versions), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions < V6.0.10), SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants) (All versions < V10.1), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions < V8.2.3), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 V7 (All versions), SIPLUS S7-400 CPU 417-4 V7 (All versions). Affected devices improperly handle specially crafted packets sent to port 102/tcp.
This could allow an attacker to create a Denial-of-Service condition. A restart is needed to restore normal operations. plural SIMATIC The product contains a buffer error vulnerability.Denial of service (DoS) It may be put into a state. The SIMATIC S7-400 CPU family is designed for process control in industrial environments.
A denial of service vulnerability exists in Siemens SIMATIC S7-400 CPUs that could be exploited by an attacker to create a denial of service condition
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202204-0320",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "simatic s7-410 v8",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "simatic s7-400h v6",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "6.0.10"
},
{
"model": "simatic s7-400 pn\\/dp v7",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "simatic s7-410 v10",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "10.1"
},
{
"model": "simatic s7-410 v8",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "simatic s7-410 v10",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "simatic s7-400 pn/dp v7",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "simatic s7-400h v6",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "simatic s7-400 h cpu family",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v6\u003c6.0.10"
},
{
"model": "simatic s7-400 pn/dp cpu family",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v7"
},
{
"model": "simatic s7-410 cpu family",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v8"
},
{
"model": "simatic s7-410 cpu family",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v10\u003c10.1"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28495"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-001565"
},
{
"db": "NVD",
"id": "CVE-2021-40368"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens reported this vulnerability to CISA.",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202204-2941"
}
],
"trust": 0.6
},
"cve": "CVE-2021-40368",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CVE-2021-40368",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 1.9,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2022-28495",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2021-40368",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2021-40368",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2021-40368",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "productcert@siemens.com",
"id": "CVE-2021-40368",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2021-40368",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2022-28495",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202204-2941",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2021-40368",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28495"
},
{
"db": "VULMON",
"id": "CVE-2021-40368"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-001565"
},
{
"db": "CNNVD",
"id": "CNNVD-202204-2941"
},
{
"db": "NVD",
"id": "CVE-2021-40368"
},
{
"db": "NVD",
"id": "CVE-2021-40368"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in SIMATIC S7-400 CPU 412-1 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 PN/DP V7 (All versions \u003c V7.0.3), SIMATIC S7-400 CPU 414-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions \u003c V7.0.3), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions \u003c V7.0.3), SIMATIC S7-400 CPU 416-2 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions \u003c V7.0.3), SIMATIC S7-400 CPU 416F-2 DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions \u003c V7.0.3), SIMATIC S7-400 CPU 417-4 DP V7 (All versions), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions \u003c V6.0.10), SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants) (All versions \u003c V10.1), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions \u003c V8.2.3), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions \u003c V7.0.3), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions \u003c V7.0.3), SIPLUS S7-400 CPU 416-3 V7 (All versions), SIPLUS S7-400 CPU 417-4 V7 (All versions). Affected devices improperly handle specially crafted packets sent to port 102/tcp. \n\nThis could allow an attacker to create a Denial-of-Service condition. A restart is needed to restore normal operations. plural SIMATIC The product contains a buffer error vulnerability.Denial of service (DoS) It may be put into a state. The SIMATIC S7-400 CPU family is designed for process control in industrial environments. \n\r\n\r\nA denial of service vulnerability exists in Siemens SIMATIC S7-400 CPUs that could be exploited by an attacker to create a denial of service condition",
"sources": [
{
"db": "NVD",
"id": "CVE-2021-40368"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-001565"
},
{
"db": "CNVD",
"id": "CNVD-2022-28495"
},
{
"db": "VULMON",
"id": "CVE-2021-40368"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2021-40368",
"trust": 3.9
},
{
"db": "SIEMENS",
"id": "SSA-557541",
"trust": 2.3
},
{
"db": "ICS CERT",
"id": "ICSA-22-104-12",
"trust": 1.5
},
{
"db": "JVN",
"id": "JVNVU91165555",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2022-001565",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2022-28495",
"trust": 0.6
},
{
"db": "CS-HELP",
"id": "SB2022042010",
"trust": 0.6
},
{
"db": "AUSCERT",
"id": "ESB-2022.4031",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202204-2941",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2021-40368",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28495"
},
{
"db": "VULMON",
"id": "CVE-2021-40368"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-001565"
},
{
"db": "CNNVD",
"id": "CNNVD-202204-2941"
},
{
"db": "NVD",
"id": "CVE-2021-40368"
}
]
},
"id": "VAR-202204-0320",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28495"
}
],
"trust": 1.40416665
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28495"
}
]
},
"last_update_date": "2024-11-23T21:32:37.374000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SSA-557541",
"trust": 0.8,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-557541.pdf"
},
{
"title": "Patch for Siemens SIMATIC S7-400 CPU Denial of Service Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/329206"
},
{
"title": "Siemens SIMATIC S7-400 Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=232910"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28495"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-001565"
},
{
"db": "CNNVD",
"id": "CNNVD-202204-2941"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-119",
"trust": 1.0
},
{
"problemtype": "Buffer error (CWE-119) [NVD Evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-001565"
},
{
"db": "NVD",
"id": "CVE-2021-40368"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.3,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-557541.pdf"
},
{
"trust": 0.9,
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-104-12"
},
{
"trust": 0.8,
"url": "http://jvn.jp/vu/jvnvu91165555/index.html"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2021-40368"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2021-40368/"
},
{
"trust": 0.6,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-104-12"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2022.4031"
},
{
"trust": 0.6,
"url": "https://www.cybersecurity-help.cz/vdb/sb2022042010"
},
{
"trust": 0.6,
"url": "https://vigilance.fr/vulnerability/simatic-s7-400-denial-of-service-via-port-102-tcp-38019"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/119.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28495"
},
{
"db": "VULMON",
"id": "CVE-2021-40368"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-001565"
},
{
"db": "CNNVD",
"id": "CNNVD-202204-2941"
},
{
"db": "NVD",
"id": "CVE-2021-40368"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2022-28495"
},
{
"db": "VULMON",
"id": "CVE-2021-40368"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-001565"
},
{
"db": "CNNVD",
"id": "CNNVD-202204-2941"
},
{
"db": "NVD",
"id": "CVE-2021-40368"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-04-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-28495"
},
{
"date": "2022-04-12T00:00:00",
"db": "VULMON",
"id": "CVE-2021-40368"
},
{
"date": "2022-04-21T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-001565"
},
{
"date": "2022-04-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202204-2941"
},
{
"date": "2022-04-12T09:15:13.343000",
"db": "NVD",
"id": "CVE-2021-40368"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-04-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-28495"
},
{
"date": "2022-04-20T00:00:00",
"db": "VULMON",
"id": "CVE-2021-40368"
},
{
"date": "2022-04-21T06:03:00",
"db": "JVNDB",
"id": "JVNDB-2022-001565"
},
{
"date": "2023-04-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202204-2941"
},
{
"date": "2024-11-21T06:23:58.173000",
"db": "NVD",
"id": "CVE-2021-40368"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202204-2941"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural \u00a0SIMATIC\u00a0 Buffer error vulnerability in the product",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-001565"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202204-2941"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.