var-202203-1978
Vulnerability from variot
Tenda AC10-1200 v15.03.06.23_EN was discovered to contain a buffer overflow in the setSmartPowerManagement function. Tenda AC10-1200 is a wireless router from China Tenda Company.
A buffer error vulnerability exists in Tenda AC10-1200, which arises from incorrect validation of data boundaries when performing operations on memory in the setSmartPowerManagement function. An attacker could exploit this vulnerability to crash the program
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202203-1978", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tendacn", "version": "15.03.06.23" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac10 firmware 15.03.06.23" }, { "model": "ac10-1200 v15.03.06.23 en", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-38544" }, { "db": "JVNDB", "id": "JVNDB-2022-007166" }, { "db": "NVD", "id": "CVE-2022-26243" } ] }, "cve": "CVE-2022-26243", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2022-26243", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2022-38544", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2022-26243", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2022-26243", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2022-26243", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2022-26243", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2022-38544", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202203-2038", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-38544" }, { "db": "JVNDB", "id": "JVNDB-2022-007166" }, { "db": "CNNVD", "id": "CNNVD-202203-2038" }, { "db": "NVD", "id": "CVE-2022-26243" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10-1200 v15.03.06.23_EN was discovered to contain a buffer overflow in the setSmartPowerManagement function. Tenda AC10-1200 is a wireless router from China Tenda Company. \n\r\n\r\nA buffer error vulnerability exists in Tenda AC10-1200, which arises from incorrect validation of data boundaries when performing operations on memory in the setSmartPowerManagement function. An attacker could exploit this vulnerability to crash the program", "sources": [ { "db": "NVD", "id": "CVE-2022-26243" }, { "db": "JVNDB", "id": "JVNDB-2022-007166" }, { "db": "CNVD", "id": "CNVD-2022-38544" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-26243", "trust": 3.8 }, { "db": "JVNDB", "id": "JVNDB-2022-007166", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2022-38544", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202203-2038", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-38544" }, { "db": "JVNDB", "id": "JVNDB-2022-007166" }, { "db": "CNNVD", "id": "CNNVD-202203-2038" }, { "db": "NVD", "id": "CVE-2022-26243" } ] }, "id": "VAR-202203-1978", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2022-38544" } ], "trust": 1.23324781 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-38544" } ] }, "last_update_date": "2024-11-23T22:47:28.529000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-120", "trust": 1.0 }, { "problemtype": "Classic buffer overflow (CWE-120) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-007166" }, { "db": "NVD", "id": "CVE-2022-26243" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://noob3xploiter.medium.com/hacking-the-tenda-ac10-1200-router-part-4-sscanf-buffer-overflow-75ae0e06abb6" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-26243" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-26243/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-38544" }, { "db": "JVNDB", "id": "JVNDB-2022-007166" }, { "db": "CNNVD", "id": "CNNVD-202203-2038" }, { "db": "NVD", "id": "CVE-2022-26243" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2022-38544" }, { "db": "JVNDB", "id": "JVNDB-2022-007166" }, { "db": "CNNVD", "id": "CNNVD-202203-2038" }, { "db": "NVD", "id": "CVE-2022-26243" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-05-20T00:00:00", "db": "CNVD", "id": "CNVD-2022-38544" }, { "date": "2023-07-12T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-007166" }, { "date": "2022-03-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202203-2038" }, { "date": "2022-03-23T19:15:07.933000", "db": "NVD", "id": "CVE-2022-26243" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-05-20T00:00:00", "db": "CNVD", "id": "CNVD-2022-38544" }, { "date": "2023-07-12T08:28:00", "db": "JVNDB", "id": "JVNDB-2022-007166" }, { "date": "2022-04-06T00:00:00", "db": "CNNVD", "id": "CNNVD-202203-2038" }, { "date": "2024-11-21T06:53:37.683000", "db": "NVD", "id": "CVE-2022-26243" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202203-2038" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda\u00a0 of \u00a0AC10\u00a0 Classic buffer overflow vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-007166" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202203-2038" } ], "trust": 0.6 } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.