var-202203-1267
Vulnerability from variot

Dell EMC AppSync versions from 3.9 to 4.3 contain a path traversal vulnerability in AppSync server. A remote unauthenticated attacker may potentially exploit this vulnerability to gain unauthorized read access to the files stored on the server filesystem, with the privileges of the running web application. DELL EMC AppSync is a replication data management software of Dell (DELL). Provides a simple, SLA-driven, self-service way to protect, restore and clone critical Microsoft and Oracle applications and VMware environments

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202203-1267",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "emc appsync",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "4.4.0.0"
      },
      {
        "model": "emc appsync",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "dell",
        "version": "3.9.0.0"
      },
      {
        "model": "dell emc appsync",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30c7\u30eb",
        "version": null
      },
      {
        "model": "dell emc appsync",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u30c7\u30eb",
        "version": null
      },
      {
        "model": "dell emc appsync",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u30c7\u30eb",
        "version": "3.9.0.0  that\u0027s all  4.4.0.0"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008691"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-24424"
      }
    ]
  },
  "cve": "CVE-2022-24424",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2022-24424",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.9,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "VHN-414171",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-24424",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 2.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 7.5,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-24424",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-24424",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "security_alert@emc.com",
            "id": "CVE-2022-24424",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-24424",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202203-1561",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-414171",
            "trust": 0.1,
            "value": "MEDIUM"
          },
          {
            "author": "VULMON",
            "id": "CVE-2022-24424",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-414171"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-24424"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008691"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1561"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-24424"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-24424"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Dell EMC AppSync versions from 3.9 to 4.3 contain a path traversal vulnerability in AppSync server. A remote unauthenticated attacker may potentially exploit this vulnerability to gain unauthorized read access to the files stored on the server filesystem, with the privileges of the running web application. DELL EMC AppSync is a replication data management software of Dell (DELL). Provides a simple, SLA-driven, self-service way to protect, restore and clone critical Microsoft and Oracle applications and VMware environments",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-24424"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008691"
      },
      {
        "db": "VULHUB",
        "id": "VHN-414171"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-24424"
      }
    ],
    "trust": 1.8
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-24424",
        "trust": 3.4
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008691",
        "trust": 0.8
      },
      {
        "db": "CS-HELP",
        "id": "SB2022031705",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1561",
        "trust": 0.6
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-42740",
        "trust": 0.1
      },
      {
        "db": "VULHUB",
        "id": "VHN-414171",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-24424",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-414171"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-24424"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008691"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1561"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-24424"
      }
    ]
  },
  "id": "VAR-202203-1267",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-414171"
      }
    ],
    "trust": 0.01
  },
  "last_update_date": "2024-11-23T22:44:02.829000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "DELL EMC AppSync Repair measures for path traversal vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=190333"
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1561"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-22",
        "trust": 1.1
      },
      {
        "problemtype": "Path traversal (CWE-22) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-414171"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008691"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-24424"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.6,
        "url": "https://www.dell.com/support/kbdoc/000197433"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-24424"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-24424/"
      },
      {
        "trust": 0.6,
        "url": "https://www.cybersecurity-help.cz/vdb/sb2022031705"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/22.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-414171"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-24424"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008691"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1561"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-24424"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-414171"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-24424"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008691"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1561"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-24424"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-21T00:00:00",
        "db": "VULHUB",
        "id": "VHN-414171"
      },
      {
        "date": "2022-04-21T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-24424"
      },
      {
        "date": "2023-07-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-008691"
      },
      {
        "date": "2022-03-17T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202203-1561"
      },
      {
        "date": "2022-04-21T21:15:07.870000",
        "db": "NVD",
        "id": "CVE-2022-24424"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-05-03T00:00:00",
        "db": "VULHUB",
        "id": "VHN-414171"
      },
      {
        "date": "2022-05-03T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-24424"
      },
      {
        "date": "2023-07-28T08:06:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-008691"
      },
      {
        "date": "2022-05-05T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202203-1561"
      },
      {
        "date": "2024-11-21T06:50:23.957000",
        "db": "NVD",
        "id": "CVE-2022-24424"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1561"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Dell\u0027s \u00a0Dell\u00a0EMC\u00a0AppSync\u00a0 Past traversal vulnerability in",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008691"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "path traversal",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1561"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.