var-202201-0606
Vulnerability from variot
Plaintext Storage of a Password vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS GENESIS64 versions 10.90 to 10.97 allows a local authenticated attacker to gain authentication information and to access the database illegally. This is because when configuration information of GridWorX, a database linkage function of GENESIS64 and MC Works64, is exported to a CSV file, the authentication information is saved in plaintext, and an attacker who can access this CSV file can gain the authentication information. Mitsubishi Electric MC Works64 and ICONICS GENESIS64 There is a vulnerability in plaintext storage of important information.Information may be obtained
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202201-0606", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "genesis64", "scope": "lte", "trust": 1.0, "vendor": "iconics", "version": "10.97" }, { "model": "mc works64", "scope": "lt", "trust": 1.0, "vendor": "mitsubishielectric", "version": "10.95.210.01" }, { "model": "genesis64", "scope": "gte", "trust": 1.0, "vendor": "iconics", "version": "10.90" }, { "model": "genesis 64", "scope": null, "trust": 0.8, "vendor": "iconics", "version": null }, { "model": "mc works64", "scope": "lte", "trust": 0.8, "vendor": "\u4e09\u83f1\u96fb\u6a5f", "version": "4.04e (10.95.210.01) and earlier" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-003879" }, { "db": "NVD", "id": "CVE-2022-23129" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:iconics:genesis64:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "10.97", "versionStartIncluding": "10.90", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:mitsubishielectric:mc_works64:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "10.95.210.01", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2022-23129" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "ICONICS and Mitsubishi Electric reported these vulnerabilities to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202201-1795" } ], "trust": 0.6 }, "cve": "CVE-2022-23129", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 2.1, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 3.9, "id": "CVE-2022-23129", "impactScore": 2.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "LOW", "trust": 1.8, "userInteractionRequired": false, "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "id": "CVE-2022-23129", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "NVD", "availabilityImpact": "None", "baseScore": 5.5, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2022-23129", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2022-23129", "trust": 1.8, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202201-1795", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-003879" }, { "db": "CNNVD", "id": "CNNVD-202201-1795" }, { "db": "NVD", "id": "CVE-2022-23129" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Plaintext Storage of a Password vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS GENESIS64 versions 10.90 to 10.97 allows a local authenticated attacker to gain authentication information and to access the database illegally. This is because when configuration information of GridWorX, a database linkage function of GENESIS64 and MC Works64, is exported to a CSV file, the authentication information is saved in plaintext, and an attacker who can access this CSV file can gain the authentication information. Mitsubishi Electric MC Works64 and ICONICS GENESIS64 There is a vulnerability in plaintext storage of important information.Information may be obtained", "sources": [ { "db": "NVD", "id": "CVE-2022-23129" }, { "db": "JVNDB", "id": "JVNDB-2022-003879" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-23129", "trust": 3.2 }, { "db": "JVN", "id": "JVNVU95403720", "trust": 2.4 }, { "db": "ICS CERT", "id": "ICSA-22-020-01", "trust": 2.4 }, { "db": "JVNDB", "id": "JVNDB-2022-003879", "trust": 0.8 }, { "db": "AUSCERT", "id": "ESB-2022.0311", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2022012109", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202201-1795", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-003879" }, { "db": "CNNVD", "id": "CNNVD-202201-1795" }, { "db": "NVD", "id": "CVE-2022-23129" } ] }, "id": "VAR-202201-0606", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.42615384 }, "last_update_date": "2023-03-11T22:22:54.544000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top\u00a0Page Mitsubishi Electric Mitsubishi\u00a0Electric\u00a0Corporation", "trust": 0.8, "url": "https://iconics.com/" }, { "title": "Mitsubishi Electric MC Works64 Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=179834" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-003879" }, { "db": "CNNVD", "id": "CNNVD-202201-1795" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-312", "trust": 1.0 }, { "problemtype": "Plaintext storage of important information (CWE-312) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-003879" }, { "db": "NVD", "id": "CVE-2022-23129" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.2, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-020-01" }, { "trust": 1.6, "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-027_en.pdf" }, { "trust": 1.6, "url": "https://jvn.jp/vu/jvnvu95403720/index.html" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-23129" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu95403720/" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-020-01" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2022.0311" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/iconics-genesis64-four-vulnerabilities-37339" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2022012109" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-003879" }, { "db": "CNNVD", "id": "CNNVD-202201-1795" }, { "db": "NVD", "id": "CVE-2022-23129" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2022-003879" }, { "db": "CNNVD", "id": "CNNVD-202201-1795" }, { "db": "NVD", "id": "CVE-2022-23129" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-03-10T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-003879" }, { "date": "2022-01-20T00:00:00", "db": "CNNVD", "id": "CNNVD-202201-1795" }, { "date": "2022-01-21T19:15:00", "db": "NVD", "id": "CVE-2022-23129" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-03-10T03:13:00", "db": "JVNDB", "id": "JVNDB-2022-003879" }, { "date": "2022-02-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202201-1795" }, { "date": "2022-01-27T20:09:00", "db": "NVD", "id": "CVE-2022-23129" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202201-1795" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Mitsubishi\u00a0Electric\u00a0MC\u00a0Works64\u00a0 and \u00a0ICONICS\u00a0GENESIS64\u00a0 Vulnerability in plaintext storage of important information in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-003879" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202201-1795" } ], "trust": 0.6 } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.