var-202110-1542
Vulnerability from variot

FreeSWITCH is a Software Defined Telecom Stack enabling the digital transformation from proprietary telecom switches to a software implementation that runs on any commodity hardware. FreeSWITCH prior to version 1.10.7 is susceptible to Denial of Service via SIP flooding. When flooding FreeSWITCH with SIP messages, it was observed that after a number of seconds the process was killed by the operating system due to memory exhaustion. By abusing this vulnerability, an attacker is able to crash any FreeSWITCH instance by flooding it with SIP messages, leading to Denial of Service. The attack does not require authentication and can be carried out over UDP, TCP or TLS. This issue was patched in version 1.10.7. FreeSWITCH Contains a vulnerability regarding the lack of free memory after expiration.Service operation interruption (DoS) It may be in a state. FreeSWITCH is a set of free and open source communication software developed by the individual developer Anthony Minesale in the United States. The software can be used to create audio, video and short message products and applications

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202110-1542",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "freeswitch",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "freeswitch",
        "version": "1.10.7"
      },
      {
        "model": "freeswitch",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "freeswitch",
        "version": null
      },
      {
        "model": "freeswitch",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "freeswitch",
        "version": "1.10.7"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-013897"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-41145"
      }
    ]
  },
  "cve": "CVE-2021-41145",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2021-41145",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-397864",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2021-41145",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "security-advisories@github.com",
            "availabilityImpact": "HIGH",
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2021-41145",
            "impactScore": 4.0,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.5,
            "baseSeverity": "High",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2021-41145",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2021-41145",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "security-advisories@github.com",
            "id": "CVE-2021-41145",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2021-41145",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202110-1765",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-397864",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-397864"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-013897"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202110-1765"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-41145"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-41145"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "FreeSWITCH is a Software Defined Telecom Stack enabling the digital transformation from proprietary telecom switches to a software implementation that runs on any commodity hardware. FreeSWITCH prior to version 1.10.7 is susceptible to Denial of Service via SIP flooding. When flooding FreeSWITCH with SIP messages, it was observed that after a number of seconds the process was killed by the operating system due to memory exhaustion. By abusing this vulnerability, an attacker is able to crash any FreeSWITCH instance by flooding it with SIP messages, leading to Denial of Service. The attack does not require authentication and can be carried out over UDP, TCP or TLS. This issue was patched in version 1.10.7. FreeSWITCH Contains a vulnerability regarding the lack of free memory after expiration.Service operation interruption (DoS) It may be in a state. FreeSWITCH is a set of free and open source communication software developed by the individual developer Anthony Minesale in the United States. The software can be used to create audio, video and short message products and applications",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-41145"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-013897"
      },
      {
        "db": "VULHUB",
        "id": "VHN-397864"
      }
    ],
    "trust": 1.71
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2021-41145",
        "trust": 3.3
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-013897",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202110-1765",
        "trust": 0.7
      },
      {
        "db": "PACKETSTORM",
        "id": "164624",
        "trust": 0.7
      },
      {
        "db": "VULHUB",
        "id": "VHN-397864",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-397864"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-013897"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202110-1765"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-41145"
      }
    ]
  },
  "id": "VAR-202110-1542",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-397864"
      }
    ],
    "trust": 0.01
  },
  "last_update_date": "2024-11-23T23:04:02.627000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "FreeSWITCH\u00a0v1.10.7\u00a0Release GitHub",
        "trust": 0.8,
        "url": "https://github.com/signalwire/freeswitch/releases/tag/v1.10.7"
      },
      {
        "title": "FreeSWITCH Remediation of resource management error vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=167159"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-013897"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202110-1765"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-400",
        "trust": 1.1
      },
      {
        "problemtype": "CWE-401",
        "trust": 1.1
      },
      {
        "problemtype": "Lack of memory release after expiration (CWE-401) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-397864"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-013897"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-41145"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.7,
        "url": "https://github.com/signalwire/freeswitch/security/advisories/ghsa-jvpq-23v4-gp3m"
      },
      {
        "trust": 1.7,
        "url": "https://github.com/signalwire/freeswitch/releases/tag/v1.10.7"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-41145"
      },
      {
        "trust": 0.6,
        "url": "http://seclists.org/fulldisclosure/2021/oct/42"
      },
      {
        "trust": 0.6,
        "url": "https://packetstormsecurity.com/files/164624/freeswitch-1.10.6-sip-flooding-denial-of-service.html"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-397864"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-013897"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202110-1765"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-41145"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-397864"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-013897"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202110-1765"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-41145"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-10-25T00:00:00",
        "db": "VULHUB",
        "id": "VHN-397864"
      },
      {
        "date": "2022-09-29T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-013897"
      },
      {
        "date": "2021-10-25T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202110-1765"
      },
      {
        "date": "2021-10-25T22:15:07.777000",
        "db": "NVD",
        "id": "CVE-2021-41145"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-08-12T00:00:00",
        "db": "VULHUB",
        "id": "VHN-397864"
      },
      {
        "date": "2022-09-29T06:31:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-013897"
      },
      {
        "date": "2022-08-15T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202110-1765"
      },
      {
        "date": "2024-11-21T06:25:35.337000",
        "db": "NVD",
        "id": "CVE-2021-41145"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202110-1765"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "FreeSWITCH\u00a0 Vulnerability regarding lack of memory release after expiration in",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-013897"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "resource management error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202110-1765"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.