A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution. Several Siemens products are vulnerable to access to memory areas after buffer termination.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Siemens SmartVNC is an industrial control equipment of Siemens (Siemens), Germany.

Siemens SmartVNC has an out-of-bounds memory access vulnerability. Remote attackers can use the vulnerability to submit special requests, which can crash the application or execute arbitrary code in the context of the application. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202105-0690",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "16"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700f",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "16"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp400f",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi comfort outdoor panels 15\\\"",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "16"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "sinamics sl150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700f",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900f",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "16"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "16"
      },
      {
        "model": "simatic hmi comfort outdoor panels 15\\\"",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi comfort outdoor panels 7\\\"",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "16"
      },
      {
        "model": "simatic hmi comfort panels 4\\\"",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "16"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700f",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "16"
      },
      {
        "model": "sinamics gm150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "16"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900f",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi comfort panels 22\\\"",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "16"
      },
      {
        "model": "simatic hmi comfort outdoor panels 7\\\"",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "16"
      },
      {
        "model": "simatic hmi comfort panels 4\\\"",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700f",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "16"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp400f",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "16"
      },
      {
        "model": "sinamics sm150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi comfort panels 22\\\"",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi comfort outdoor panels 15\\\"",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "16"
      },
      {
        "model": "sinamics sm150i",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi comfort panels 4\\\"",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "16"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi comfort outdoor panels 15\\\"",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp400f",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "sinamics gh150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi comfort outdoor panels 7\\\"",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "16"
      },
      {
        "model": "simatic hmi comfort panels 4\\\"",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "sinamics gl150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "16"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900f",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "16"
      },
      {
        "model": "simatic hmi comfort panels 22\\\"",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "16"
      },
      {
        "model": "simatic hmi comfort outdoor panels 7\\\"",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "sinamics sm120",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900f",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp400f",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "16"
      },
      {
        "model": "simatic hmi comfort panels 22\\\"",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "sinamics sh150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "sinamics sh150",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "sinamics sl150",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "sinamics sm120",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "sinamics sm150i",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "simatic hmi comfort outdoor panels 7\"",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "sinamics gh150",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "sinamics sm150",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "sinamics gl150",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "sinamics gm150",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "smartvnc",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-37750"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-006949"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-27384"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens reported these vulnerabilities to CISA.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202105-548"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2021-27384",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2021-27384",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.9,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2021-37750",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2021-27384",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2021-27384",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2021-27384",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2021-27384",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2021-37750",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202104-975",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202105-548",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULMON",
            "id": "CVE-2021-27384",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-37750"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-27384"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-006949"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202105-548"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-27384"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution. Several Siemens products are vulnerable to access to memory areas after buffer termination.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Siemens SmartVNC is an industrial control equipment of Siemens (Siemens), Germany. \n\r\n\r\nSiemens SmartVNC has an out-of-bounds memory access vulnerability. Remote attackers can use the vulnerability to submit special requests, which can crash the application or execute arbitrary code in the context of the application. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-27384"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-006949"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-37750"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-27384"
      }
    ],
    "trust": 2.79
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2021-27384",
        "trust": 3.9
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-21-131-11",
        "trust": 2.5
      },
      {
        "db": "SIEMENS",
        "id": "SSA-286838",
        "trust": 1.7
      },
      {
        "db": "SIEMENS",
        "id": "SSA-538778",
        "trust": 1.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-21-131-12",
        "trust": 1.2
      },
      {
        "db": "JVN",
        "id": "JVNVU91051134",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-006949",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-37750",
        "trust": 0.6
      },
      {
        "db": "CS-HELP",
        "id": "SB2021041363",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975",
        "trust": 0.6
      },
      {
        "db": "CS-HELP",
        "id": "SB2021051206",
        "trust": 0.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-21-131-04",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202105-548",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-27384",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-37750"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-27384"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-006949"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202105-548"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-27384"
      }
    ]
  },
  "id": "VAR-202105-0690",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-37750"
      }
    ],
    "trust": 1.205898611111111
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-37750"
      }
    ]
  },
  "last_update_date": "2024-08-14T13:12:43.619000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-286838 Siemens\u00a0Security\u00a0Advisory",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
      },
      {
        "title": "Patch for Siemens SmartVNC memory out-of-bounds access vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/268666"
      },
      {
        "title": "Siemens SmartVNC Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=155975"
      },
      {
        "title": "Siemens Security Advisories: Siemens Security Advisory",
        "trust": 0.1,
        "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=43c9c77785b8d29daef02185f41ca476"
      },
      {
        "title": "Siemens Security Advisories: Siemens Security Advisory",
        "trust": 0.1,
        "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=9465a8ef1f8c1b0042244cb02cfe271e"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-37750"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-27384"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-006949"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202105-548"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-788",
        "trust": 1.0
      },
      {
        "problemtype": "Access to memory area after buffer termination (CWE-788) [ Other ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-006949"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-27384"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.7,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
      },
      {
        "trust": 1.6,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
      },
      {
        "trust": 1.6,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
      },
      {
        "trust": 1.2,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu91051134/"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-27384"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-131-11"
      },
      {
        "trust": 0.6,
        "url": "https://www.cybersecurity-help.cz/vdb/sb2021041363"
      },
      {
        "trust": 0.6,
        "url": "https://www.cybersecurity-help.cz/vdb/sb2021051206"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-04"
      },
      {
        "trust": 0.6,
        "url": "https://vigilance.fr/vulnerability/smartvnc-multiple-vulnerabilities-35360"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/788.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://cert-portal.siemens.com/productcert/txt/ssa-286838.txt"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-37750"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-27384"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-006949"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202105-548"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-27384"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-37750"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-27384"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-006949"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202105-548"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-27384"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-05-28T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-37750"
      },
      {
        "date": "2021-05-12T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-27384"
      },
      {
        "date": "2022-01-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-006949"
      },
      {
        "date": "2021-04-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "date": "2021-05-11T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202105-548"
      },
      {
        "date": "2021-05-12T14:15:11.677000",
        "db": "NVD",
        "id": "CVE-2021-27384"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-05-28T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-37750"
      },
      {
        "date": "2021-05-21T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-27384"
      },
      {
        "date": "2022-01-26T07:30:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-006949"
      },
      {
        "date": "2021-04-14T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "date": "2021-10-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202105-548"
      },
      {
        "date": "2021-12-16T18:26:10.080000",
        "db": "NVD",
        "id": "CVE-2021-27384"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202105-548"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Vulnerabilities in access to memory areas after buffer termination in multiple Siemens products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-006949"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202105-548"
      }
    ],
    "trust": 1.2
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.