var-202011-1251
Vulnerability from variot
NULL pointer dereferences vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet. Provided by Mitsubishi Electric Corporation MELSEC iQ-R Of the series EtherNet/IP Network interface unit, PROFINET IO Controller unit, high-speed data logger unit, MES Interface unit and OPC UA Of the server unit TCP/IP There are multiple vulnerabilities in the stack. ‥ * Buffer error (CWE-119) - CVE-2020-5653 ‥ * Session immobilization (CWE-384) - CVE-2020-5654 ‥ * NULL Pointer dereference (CWE-476) - CVE-2020-5655 ‥ * Inappropriate access control (CWE-284) - CVE-2020-5656 ‥ * Insert or change arguments (CWE-88) - CVE-2020-5657 ‥ * Resource management issues (CWE-399) - CVE-2020-5658 This vulnerability information is provided by the developer for the purpose of disseminating it to product users. JPCERT/CC Report to JPCERT/CC Coordinated with the developer.Receiving packets crafted by a third party can cause the product's network functionality to stop or malicious programs to run
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202011-1251", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "melsec iq-rj71pn92", "scope": "eq", "trust": 1.0, "vendor": "mitsubishielectric", "version": null }, { "model": "melsec iq-rd81dl96", "scope": "eq", "trust": 1.0, "vendor": "mitsubishielectric", "version": null }, { "model": "melsec iq-rd81opc96", "scope": "eq", "trust": 1.0, "vendor": "mitsubishielectric", "version": null }, { "model": "melsec iq-rd81mes96n", "scope": "eq", "trust": 1.0, "vendor": "mitsubishielectric", "version": null }, { "model": "melsec iq-rj71eip91", "scope": "eq", "trust": 1.0, "vendor": "mitsubishielectric", "version": null }, { "model": "melsec iq-r series", "scope": "eq", "trust": 0.8, "vendor": "mitsubishi electric", "version": "ethernet/ip \u30cd\u30c3\u30c8\u30ef\u30fc\u30af\u30a4\u30f3\u30bf\u30d5\u30a7\u30fc\u30b9\u30e6\u30cb\u30c3\u30c8 rj71eip91: \u30b7\u30ea\u30a2\u30eb no. \u306e\u4e0a 2\u6841\u304c \u201d02\u201d \u304a\u3088\u3073\u305d\u308c\u4ee5\u4e0b" }, { "model": "melsec iq-r series", "scope": "eq", "trust": 0.8, "vendor": "mitsubishi electric", "version": "mes \u30a4\u30f3\u30bf\u30d5\u30a7\u30fc\u30b9\u30e6\u30cb\u30c3\u30c8 rd81mes96n: \u30b7\u30ea\u30a2\u30eb no. \u306e\u4e0a 2\u6841\u304c \u201d04\u201d \u304a\u3088\u3073\u305d\u308c\u4ee5\u4e0b" }, { "model": "melsec iq-r series", "scope": "eq", "trust": 0.8, "vendor": "mitsubishi electric", "version": "opc ua \u30b5\u30fc\u30d0\u30e6\u30cb\u30c3\u30c8 rd81opc96: \u30b7\u30ea\u30a2\u30eb no. \u306e\u4e0a 2\u6841\u304c \u201d04\u201d \u304a\u3088\u3073\u305d\u308c\u4ee5\u4e0b" }, { "model": "melsec iq-r series", "scope": "eq", "trust": 0.8, "vendor": "mitsubishi electric", "version": "profinet io \u30b3\u30f3\u30c8\u30ed\u30fc\u30e9\u30e6\u30cb\u30c3\u30c8 rj71pn92: \u30b7\u30ea\u30a2\u30eb no. \u306e\u4e0a 2\u6841\u304c \u201d01\u201d \u304a\u3088\u3073\u305d\u308c\u4ee5\u4e0b" }, { "model": "melsec iq-r series", "scope": "eq", "trust": 0.8, "vendor": "mitsubishi electric", "version": "\u9ad8\u901f\u30c7\u30fc\u30bf\u30ed\u30ac\u30fc\u30e6\u30cb\u30c3\u30c8 rd81dl96: \u30b7\u30ea\u30a2\u30eb no. \u306e\u4e0a 2\u6841\u304c \u201d08\u201d \u304a\u3088\u3073\u305d\u308c\u4ee5\u4e0b" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-009429" }, { "db": "NVD", "id": "CVE-2020-5655" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-rj71eip91_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-rj71eip91:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-rj71eip91_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-rj71eip91:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-rj71pn92_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-rj71pn92:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-rj71pn92_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-rj71pn92:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-rd81dl96_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-rd81dl96:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-rd81dl96_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-rd81dl96:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-rd81mes96n_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-rd81mes96n:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-rd81mes96n_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-rd81mes96n:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-rd81opc96_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-rd81opc96:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:mitsubishielectric:melsec_iq-rd81opc96_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:mitsubishielectric:melsec_iq-rd81opc96:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-5655" } ] }, "cve": "CVE-2020-5655", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2020-5655", "impactScore": 2.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA score", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-009429", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 1.6, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA score", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2020-009429", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 1.6, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2020-5655", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "IPA score", "availabilityImpact": "High", "baseScore": 7.1, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2020-009429", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA score", "availabilityImpact": "Low", "baseScore": 5.3, "baseSeverity": "Medium", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2020-009429", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.0" } ], "severity": [ { "author": "IPA", "id": "JVNDB-2020-009429", "trust": 2.4, "value": "High" }, { "author": "IPA", "id": "JVNDB-2020-009429", "trust": 1.6, "value": "Critical" }, { "author": "NVD", "id": "CVE-2020-5655", "trust": 1.0, "value": "HIGH" }, { "author": "IPA", "id": "JVNDB-2020-009429", "trust": 0.8, "value": "Medium" }, { "author": "CNNVD", "id": "CNNVD-202010-1664", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-009429" }, { "db": "JVNDB", "id": "JVNDB-2020-009429" }, { "db": "JVNDB", "id": "JVNDB-2020-009429" }, { "db": "JVNDB", "id": "JVNDB-2020-009429" }, { "db": "JVNDB", "id": "JVNDB-2020-009429" }, { "db": "JVNDB", "id": "JVNDB-2020-009429" }, { "db": "CNNVD", "id": "CNNVD-202010-1664" }, { "db": "NVD", "id": "CVE-2020-5655" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "NULL pointer dereferences vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet. Provided by Mitsubishi Electric Corporation MELSEC iQ-R Of the series EtherNet/IP Network interface unit, PROFINET IO Controller unit, high-speed data logger unit, MES Interface unit and OPC UA Of the server unit TCP/IP There are multiple vulnerabilities in the stack. \u2025 * Buffer error (CWE-119) - CVE-2020-5653 \u2025 * Session immobilization (CWE-384) - CVE-2020-5654 \u2025 * NULL Pointer dereference (CWE-476) - CVE-2020-5655 \u2025 * Inappropriate access control (CWE-284) - CVE-2020-5656 \u2025 * Insert or change arguments (CWE-88) - CVE-2020-5657 \u2025 * Resource management issues (CWE-399) - CVE-2020-5658 This vulnerability information is provided by the developer for the purpose of disseminating it to product users. JPCERT/CC Report to JPCERT/CC Coordinated with the developer.Receiving packets crafted by a third party can cause the product\u0027s network functionality to stop or malicious programs to run", "sources": [ { "db": "NVD", "id": "CVE-2020-5655" }, { "db": "JVNDB", "id": "JVNDB-2020-009429" }, { "db": "VULMON", "id": "CVE-2020-5655" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "JVN", "id": "JVNVU92513419", "trust": 2.5 }, { "db": "NVD", "id": "CVE-2020-5655", "trust": 2.5 }, { "db": "ICS CERT", "id": "ICSA-20-303-02", "trust": 1.4 }, { "db": "JVNDB", "id": "JVNDB-2020-009429", "trust": 0.8 }, { "db": "AUSCERT", "id": "ESB-2020.3753", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202010-1664", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2020-5655", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2020-5655" }, { "db": "JVNDB", "id": "JVNDB-2020-009429" }, { "db": "CNNVD", "id": "CNNVD-202010-1664" }, { "db": "NVD", "id": "CVE-2020-5655" } ] }, "id": "VAR-202011-1251", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.21111111 }, "last_update_date": "2022-05-04T09:15:40.665000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "MELSEC iQ-R\u30b7\u30ea\u30fc\u30ba\u306e\u5404\u7a2e\u60c5\u5831\uff0f\u30cd\u30c3\u30c8\u30ef\u30fc\u30af\u30e6\u30cb\u30c3\u30c8\u306e TCP/IP\u6a5f\u80fd\u306b\u304a\u3051\u308b\u8907\u6570\u306e\u8106\u5f31\u6027", "trust": 0.8, "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf" }, { "title": "Multiple Mitsubishi Electric Product code issue vulnerability fixes", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=133128" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-009429" }, { "db": "CNNVD", "id": "CNNVD-202010-1664" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-476", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2020-5655" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://jvn.jp/vu/jvnvu92513419/index.html" }, { "trust": 1.7, "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf" }, { "trust": 1.7, "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf" }, { "trust": 1.4, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-303-02" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5654" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5655" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5656" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5657" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5658" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5653" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu92513419/" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-5655" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2020.3753/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2020-5655" }, { "db": "JVNDB", "id": "JVNDB-2020-009429" }, { "db": "CNNVD", "id": "CNNVD-202010-1664" }, { "db": "NVD", "id": "CVE-2020-5655" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2020-5655" }, { "db": "JVNDB", "id": "JVNDB-2020-009429" }, { "db": "CNNVD", "id": "CNNVD-202010-1664" }, { "db": "NVD", "id": "CVE-2020-5655" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-11-02T00:00:00", "db": "VULMON", "id": "CVE-2020-5655" }, { "date": "2020-11-05T06:29:48", "db": "JVNDB", "id": "JVNDB-2020-009429" }, { "date": "2020-10-29T00:00:00", "db": "CNNVD", "id": "CNNVD-202010-1664" }, { "date": "2020-11-02T21:15:00", "db": "NVD", "id": "CVE-2020-5655" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-11-10T00:00:00", "db": "VULMON", "id": "CVE-2020-5655" }, { "date": "2020-11-05T06:29:48", "db": "JVNDB", "id": "JVNDB-2020-009429" }, { "date": "2020-11-12T00:00:00", "db": "CNNVD", "id": "CNNVD-202010-1664" }, { "date": "2020-11-10T14:34:00", "db": "NVD", "id": "CVE-2020-5655" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202010-1664" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Made by Mitsubishi Electric MELSEC iQ-R Multiple vulnerabilities in the series", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-009429" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "code problem", "sources": [ { "db": "CNNVD", "id": "CNNVD-202010-1664" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.