This vulnerability allows remote attackers to create arbitrary files on affected installations of Rockwell Automation FactoryTalk View SE. Authentication is not required to exploit this vulnerability.The specific flaw exists within the handling of fileName parameter in the RegisterEDSFiles tag. The issue results in the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of SYSTEM.

Show details on source website


{
  "affected_products": {
    "_id": null,
    "data": [
      {
        "_id": null,
        "model": "factorytalk view se",
        "scope": null,
        "trust": 0.7,
        "vendor": "rockwell automation",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-20-734"
      }
    ]
  },
  "credits": {
    "_id": null,
    "data": "Sharon Brizinov, Amir Preminger of Claroty Research",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-20-734"
      }
    ],
    "trust": 0.7
  },
  "cvss": {
    "_id": null,
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "ZDI",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "ZDI-20-734",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 0.7,
            "userInteraction": "NONE",
            "vectorString": "AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "ZDI",
            "id": "ZDI-20-734",
            "trust": 0.7,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-20-734"
      }
    ]
  },
  "description": {
    "_id": null,
    "data": "This vulnerability allows remote attackers to create arbitrary files on affected installations of Rockwell Automation FactoryTalk View SE. Authentication is not required to exploit this vulnerability.The specific flaw exists within the handling of fileName parameter in the RegisterEDSFiles tag. The issue results in the lack of proper validation of a user-supplied path prior to using it in file operations.  An attacker can leverage this vulnerability to execute code in the context of SYSTEM.",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-20-734"
      }
    ],
    "trust": 0.7
  },
  "external_ids": {
    "_id": null,
    "data": [
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-10298",
        "trust": 0.7
      },
      {
        "db": "ZDI",
        "id": "ZDI-20-734",
        "trust": 0.7
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-20-734"
      }
    ]
  },
  "id": "VAR-202006-1966",
  "iot": {
    "_id": null,
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.67777777
  },
  "last_update_date": "2022-05-17T01:46:20.239000Z",
  "patch": {
    "_id": null,
    "data": [
      {
        "title": "Rockwell Automation has issued an update to correct this vulnerability.",
        "trust": 0.7,
        "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1126945"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-20-734"
      }
    ]
  },
  "references": {
    "_id": null,
    "data": [
      {
        "trust": 0.7,
        "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1126945"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-20-734"
      }
    ]
  },
  "sources": {
    "_id": null,
    "data": [
      {
        "db": "ZDI",
        "id": "ZDI-20-734",
        "ident": null
      }
    ]
  },
  "sources_release_date": {
    "_id": null,
    "data": [
      {
        "date": "2020-06-22T00:00:00",
        "db": "ZDI",
        "id": "ZDI-20-734",
        "ident": null
      }
    ]
  },
  "sources_update_date": {
    "_id": null,
    "data": [
      {
        "date": "2020-06-22T00:00:00",
        "db": "ZDI",
        "id": "ZDI-20-734",
        "ident": null
      }
    ]
  },
  "title": {
    "_id": null,
    "data": "(Pwn2Own) Rockwell Automation FactoryTalk View SE RegisterEDSFiles Directory Traversal Remote Code Execution Vulnerability",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-20-734"
      }
    ],
    "trust": 0.7
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…