var-202003-0928
Vulnerability from variot

Ricoh SP C250DN 1.05 devices have an Authentication Method Vulnerable to Brute Force Attacks. Some Ricoh printers did not implement account lockout. Therefore, it was possible to obtain the local account credentials by brute force. plural Ricoh SP C250DN Devices contain vulnerabilities in insufficient protection of credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. RICOH SP C250DN is a printer from RICOH Corporation of Japan.

There is a security vulnerability in Ricoh SP C250DN version 1.05, which originated from the device's failure to lock accounts

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202003-0928",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "sp c250dn",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "ricoh",
        "version": "1.05"
      },
      {
        "model": "sp c250sf",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "ricoh",
        "version": "*"
      },
      {
        "model": "sp c252dn",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "ricoh",
        "version": "*"
      },
      {
        "model": "sp c252sf",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "ricoh",
        "version": "*"
      },
      {
        "model": "sp c250sf",
        "scope": null,
        "trust": 0.8,
        "vendor": "ricoh",
        "version": null
      },
      {
        "model": "sp c252dn",
        "scope": null,
        "trust": 0.8,
        "vendor": "ricoh",
        "version": null
      },
      {
        "model": "sp c252sf",
        "scope": null,
        "trust": 0.8,
        "vendor": "ricoh",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-19586"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-014957"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-14299"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:ricoh:sp_c250dn_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:ricoh:sp_c250sf_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:ricoh:sp_c252dn_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:ricoh:sp_c252sf_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-014957"
      }
    ]
  },
  "cve": "CVE-2019-14299",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2019-14299",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 5.0,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "JVNDB-2019-014957",
            "impactScore": null,
            "integrityImpact": "None",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2020-19586",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2019-14299",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2019-014957",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2019-14299",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "JVNDB-2019-014957",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2020-19586",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202003-867",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-19586"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-014957"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202003-867"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-14299"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Ricoh SP C250DN 1.05 devices have an Authentication Method Vulnerable to Brute Force Attacks. Some Ricoh printers did not implement account lockout. Therefore, it was possible to obtain the local account credentials by brute force. plural Ricoh SP C250DN Devices contain vulnerabilities in insufficient protection of credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. RICOH SP C250DN is a printer from RICOH Corporation of Japan. \n\r\n\r\nThere is a security vulnerability in Ricoh SP C250DN version 1.05, which originated from the device\u0027s failure to lock accounts",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-14299"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-014957"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-19586"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2019-14299",
        "trust": 3.0
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-014957",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-19586",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2020.4167",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202003-867",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-19586"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-014957"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202003-867"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-14299"
      }
    ]
  },
  "id": "VAR-202003-0928",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-19586"
      }
    ],
    "trust": 1.1948718
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-19586"
      }
    ]
  },
  "last_update_date": "2024-11-23T21:32:11.205000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Support \u0026 Downloads",
        "trust": 0.8,
        "url": "https://www.ricoh-usa.com/en/support-and-download"
      },
      {
        "title": "Patch for RICOH SP C250DN logic flaw vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/211087"
      },
      {
        "title": "RICOH SP C250DN Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=112087"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-19586"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-014957"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202003-867"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-307",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-522",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-014957"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-14299"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.2,
        "url": "https://www.nccgroup.trust/us/our-research/technical-advisory-multiple-vulnerabilities-in-ricoh-printers/"
      },
      {
        "trust": 2.0,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-14299"
      },
      {
        "trust": 1.6,
        "url": "https://www.ricoh-usa.com/en/support-and-download"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-14299"
      },
      {
        "trust": 0.8,
        "url": "https://www.nccgroup.trust/us/our-research/technical-advisory-multiple-vulnerabilities-in-ricoh-printers/#d"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2020.4167/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-19586"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-014957"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202003-867"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-14299"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-19586"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-014957"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202003-867"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-14299"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-03-26T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-19586"
      },
      {
        "date": "2020-03-31T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-014957"
      },
      {
        "date": "2020-03-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202003-867"
      },
      {
        "date": "2020-03-13T19:15:16.697000",
        "db": "NVD",
        "id": "CVE-2019-14299"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-03-26T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-19586"
      },
      {
        "date": "2020-03-31T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-014957"
      },
      {
        "date": "2020-11-25T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202003-867"
      },
      {
        "date": "2024-11-21T04:26:24.413000",
        "db": "NVD",
        "id": "CVE-2019-14299"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202003-867"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Ricoh SP C250DN Inadequate protection of credentials on devices",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-014957"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202003-867"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…