var-201909-0864
Vulnerability from variot

A vulnerability has been identified in IE/WSN-PA Link WirelessHART Gateway (All versions). The integrated configuration web server of the affected device could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known. IE/WSN-PA Link WirelessHART Gateway Contains a cross-site scripting vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. IE/WSN-PA Link is a gateway that connects a WirelessHART network to Industrial Ethernet. The vulnerability stems from the lack of proper validation of client data for web applications. An attacker could exploit the vulnerability to execute client code

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201909-0864",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ie\\/wsn-pa link wirelesshart gateway",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "ie/wsn-pa link wirelesshart gateway",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "ie/wsn-pa link",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "ie wsn pa link wirelesshart gateway",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "4a774231-21cb-486e-b391-9a0e6e02394c"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-31386"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-009306"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-13923"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:siemens:ie%2fwsn-pa_link_wirelesshart_gateway_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-009306"
      }
    ]
  },
  "cve": "CVE-2019-13923",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.6,
            "id": "CVE-2019-13923",
            "impactScore": 2.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "HIGH",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.6,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 4.9,
            "id": "CNVD-2019-31386",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:H/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "HIGH",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.6,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 4.9,
            "id": "4a774231-21cb-486e-b391-9a0e6e02394c",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:H/Au:N/C:C/I:C/A:C",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.6,
            "id": "VHN-145818",
            "impactScore": 2.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:M/AU:N/C:N/I:P/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.6,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2019-13923",
            "impactScore": 6.0,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "trust": 1.0,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.6,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2019-13923",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Changed",
            "trust": 0.8,
            "userInteraction": "Required",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2019-13923",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2019-13923",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-31386",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201909-459",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "IVD",
            "id": "4a774231-21cb-486e-b391-9a0e6e02394c",
            "trust": 0.2,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-145818",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "4a774231-21cb-486e-b391-9a0e6e02394c"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-31386"
      },
      {
        "db": "VULHUB",
        "id": "VHN-145818"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-009306"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201909-459"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-13923"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in IE/WSN-PA Link WirelessHART Gateway (All versions). The integrated configuration web server of the affected device could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known. IE/WSN-PA Link WirelessHART Gateway Contains a cross-site scripting vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. IE/WSN-PA Link is a gateway that connects a WirelessHART network to Industrial Ethernet. The vulnerability stems from the lack of proper validation of client data for web applications. An attacker could exploit the vulnerability to execute client code",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-13923"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-009306"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-31386"
      },
      {
        "db": "IVD",
        "id": "4a774231-21cb-486e-b391-9a0e6e02394c"
      },
      {
        "db": "VULHUB",
        "id": "VHN-145818"
      }
    ],
    "trust": 2.43
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2019-13923",
        "trust": 3.3
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-19-253-04",
        "trust": 3.1
      },
      {
        "db": "SIEMENS",
        "id": "SSA-191683",
        "trust": 1.7
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201909-459",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-31386",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-009306",
        "trust": 0.8
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2019.3445",
        "trust": 0.6
      },
      {
        "db": "IVD",
        "id": "4A774231-21CB-486E-B391-9A0E6E02394C",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-145818",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "4a774231-21cb-486e-b391-9a0e6e02394c"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-31386"
      },
      {
        "db": "VULHUB",
        "id": "VHN-145818"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-009306"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201909-459"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-13923"
      }
    ]
  },
  "id": "VAR-201909-0864",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "4a774231-21cb-486e-b391-9a0e6e02394c"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-31386"
      },
      {
        "db": "VULHUB",
        "id": "VHN-145818"
      }
    ],
    "trust": 1.9
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS",
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      },
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.2
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "4a774231-21cb-486e-b391-9a0e6e02394c"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-31386"
      }
    ]
  },
  "last_update_date": "2024-11-23T23:08:15.574000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-191683",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-191683.pdf"
      },
      {
        "title": "Siemens IE/WSN-PA Link WirelessHART Gateway Cross-Site Scripting Vulnerability Patch",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/180399"
      },
      {
        "title": "Siemens IE-WSN-PA Link WirelessHART Gateway Fixes for cross-site scripting vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=98052"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-31386"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-009306"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201909-459"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-79",
        "trust": 1.9
      },
      {
        "problemtype": "CWE-80",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-145818"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-009306"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-13923"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "https://www.us-cert.gov/ics/advisories/icsa-19-253-04"
      },
      {
        "trust": 1.7,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-191683.pdf"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-13923"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-13923"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2019.3445/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-31386"
      },
      {
        "db": "VULHUB",
        "id": "VHN-145818"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-009306"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201909-459"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-13923"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "4a774231-21cb-486e-b391-9a0e6e02394c"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-31386"
      },
      {
        "db": "VULHUB",
        "id": "VHN-145818"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-009306"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201909-459"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-13923"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-09-16T00:00:00",
        "db": "IVD",
        "id": "4a774231-21cb-486e-b391-9a0e6e02394c"
      },
      {
        "date": "2019-09-16T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-31386"
      },
      {
        "date": "2019-09-13T00:00:00",
        "db": "VULHUB",
        "id": "VHN-145818"
      },
      {
        "date": "2019-09-18T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-009306"
      },
      {
        "date": "2019-09-10T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201909-459"
      },
      {
        "date": "2019-09-13T17:15:11.977000",
        "db": "NVD",
        "id": "CVE-2019-13923"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-09-16T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-31386"
      },
      {
        "date": "2019-09-24T00:00:00",
        "db": "VULHUB",
        "id": "VHN-145818"
      },
      {
        "date": "2019-10-04T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-009306"
      },
      {
        "date": "2019-09-30T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201909-459"
      },
      {
        "date": "2024-11-21T04:25:42.430000",
        "db": "NVD",
        "id": "CVE-2019-13923"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201909-459"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens IE/WSN-PA Link WirelessHART Gateway Cross-Site Scripting Vulnerability",
    "sources": [
      {
        "db": "IVD",
        "id": "4a774231-21cb-486e-b391-9a0e6e02394c"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-31386"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "XSS",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201909-459"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…