var-201908-0714
Vulnerability from variot
Wind River VxWorks 6.6 through 6.9 has a Buffer Overflow in the DHCP client component. There is an IPNET security vulnerability: Heap overflow in DHCP Offer/ACK parsing inside ipdhcpc. Wind River VxWorks Contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Wind River Systems VxWorks is an embedded real-time operating system (RTOS) from Wind River Systems. An attacker could exploit the vulnerability to overwrite the heap and execute code. The following products and versions are affected: Wind River Systems VxWorks Version 6.9, Version 6.8, Version 6.7, Version 6.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201908-0714", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": null, "scope": "eq", "trust": 2.4, "vendor": "sonicos", "version": "*" }, { "model": "sonicos", "scope": "gte", "trust": 1.0, "vendor": "sonicwall", "version": "6.2.5.0" }, { "model": "sonicos", "scope": "lte", "trust": 1.0, "vendor": "sonicwall", "version": "6.5.0.3" }, { "model": "sonicos", "scope": "gte", "trust": 1.0, "vendor": "sonicwall", "version": "6.2.6.0" }, { "model": "sonicos", "scope": "lte", "trust": 1.0, "vendor": "sonicwall", "version": "6.5.1.4" }, { "model": "sonicos", "scope": "gte", "trust": 1.0, "vendor": "sonicwall", "version": "6.5.4.0." }, { "model": "hirschmann hios", "scope": "lte", "trust": 1.0, "vendor": "belden", "version": "07.5.01" }, { "model": "sonicos", "scope": "gte", "trust": 1.0, "vendor": "sonicwall", "version": "5.9.0.0" }, { "model": "e-series santricity os controller", "scope": "lte", "trust": 1.0, "vendor": "netapp", "version": "8.40.50.00" }, { "model": "vxworks", "scope": "lt", "trust": 1.0, "vendor": "windriver", "version": "6.9.4" }, { "model": "sonicos", "scope": "gte", "trust": 1.0, "vendor": "sonicwall", "version": "6.2.7.0" }, { "model": "ruggedcom win7000", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "bs5.2.461.17" }, { "model": "hirschmann hios", "scope": "lte", "trust": 1.0, "vendor": "belden", "version": "07.2.04" }, { "model": "sonicos", "scope": "lte", "trust": 1.0, "vendor": "sonicwall", "version": "6.2.7.4" }, { "model": "hirschmann hios", "scope": "lte", "trust": 1.0, "vendor": "belden", "version": "05.3.06" }, { "model": "sonicos", "scope": "gte", "trust": 1.0, "vendor": "sonicwall", "version": "5.9.1.0." }, { "model": "ruggedcom win7200", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "bs5.2.461.17" }, { "model": "garrettcom magnum dx940e", "scope": "lte", "trust": 1.0, "vendor": "belden", "version": "1.0.1_y7" }, { "model": "siprotec 5", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "7.59" }, { "model": "sonicos", "scope": "eq", "trust": 1.0, "vendor": "sonicwall", "version": "6.2.7.7" }, { "model": "sonicos", "scope": "gte", "trust": 1.0, "vendor": "sonicwall", "version": "6.2.0.0" }, { "model": "sonicos", "scope": "lte", "trust": 1.0, "vendor": "sonicwall", "version": "6.5.2.3" }, { "model": "e-series santricity os controller", "scope": "gte", "trust": 1.0, "vendor": "netapp", "version": "8.00" }, { "model": "sonicos", "scope": "lte", "trust": 1.0, "vendor": "sonicwall", "version": "5.9.1.12" }, { "model": "sonicos", "scope": "gte", "trust": 1.0, "vendor": "sonicwall", "version": "6.2.9.0" }, { "model": "sonicos", "scope": "gte", "trust": 1.0, "vendor": "sonicwall", "version": "6.5.1.0" }, { "model": "sonicos", "scope": "lte", "trust": 1.0, "vendor": "sonicwall", "version": "6.2.9.2" }, { "model": "sonicos", "scope": "eq", "trust": 1.0, "vendor": "sonicwall", "version": "6.2.7.0" }, { "model": "sonicos", "scope": "lte", "trust": 1.0, "vendor": "sonicwall", "version": "6.2.3.1" }, { "model": "sonicos", "scope": "eq", "trust": 1.0, "vendor": "sonicwall", "version": "6.2.7.1" }, { "model": "ruggedcom win7018", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "bs5.2.461.17" }, { "model": "sonicos", "scope": "gte", "trust": 1.0, "vendor": "sonicwall", "version": "6.2.4.0" }, { "model": "sonicos", "scope": "lte", "trust": 1.0, "vendor": "sonicwall", "version": "6.5.3.3" }, { "model": "sonicos", "scope": "gte", "trust": 1.0, "vendor": "sonicwall", "version": "6.5.0.0" }, { "model": "sonicos", "scope": "lte", "trust": 1.0, "vendor": "sonicwall", "version": "6.2.5.3" }, { "model": "vxworks", "scope": "gte", "trust": 1.0, "vendor": "windriver", "version": "6.5" }, { "model": "ruggedcom win7025", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "bs5.2.461.17" }, { "model": "sonicos", "scope": "lte", "trust": 1.0, "vendor": "sonicwall", "version": "6.2.4.3" }, { "model": "sonicos", "scope": "gte", "trust": 1.0, "vendor": "sonicwall", "version": "6.5.2.0" }, { "model": "sonicos", "scope": "lte", "trust": 1.0, "vendor": "sonicwall", "version": "6.2.6.1" }, { "model": "sonicos", "scope": "lte", "trust": 1.0, "vendor": "sonicwall", "version": "5.9.0.7" }, { "model": "sonicos", "scope": "gte", "trust": 1.0, "vendor": "sonicwall", "version": "6.5.3.0" }, { "model": "siprotec 5", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "7.91" }, { "model": "hirschmann hios", "scope": "lte", "trust": 1.0, "vendor": "belden", "version": "07.0.07" }, { "model": "sonicos", "scope": "lte", "trust": 1.0, "vendor": "sonicwall", "version": "6.5.4.3" }, { "model": "e-series santricity os controller", "scope": null, "trust": 0.8, "vendor": "netapp", "version": null }, { "model": "sonicos", "scope": null, "trust": 0.8, "vendor": "sonicwall", "version": null }, { "model": "vxworks", "scope": "eq", "trust": 0.8, "vendor": "wind river", "version": "6.6 to 6.9" }, { "model": "siprotec 5", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "river systems wind river systems vxworks", "scope": "eq", "trust": 0.6, "vendor": "wind", "version": "6.9" }, { "model": "river systems wind river systems vxworks", "scope": "eq", "trust": 0.6, "vendor": "wind", "version": "6.8" }, { "model": "river systems wind river systems vxworks", "scope": "eq", "trust": 0.6, "vendor": "wind", "version": "6.7" }, { "model": "river systems wind river systems vxworks", "scope": "eq", "trust": 0.6, "vendor": "wind", "version": "6.6" }, { "model": null, "scope": "eq", "trust": 0.4, "vendor": "siprotec 5", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "vxworks", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "e series santricity os controller", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sonicos", "version": "6.2.7.0" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sonicos", "version": "6.2.7.1" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sonicos", "version": "6.2.7.7" } ], "sources": [ { "db": "IVD", "id": "93543796-4304-43f2-9d14-11a08f3135cc" }, { "db": "CNVD", "id": "CNVD-2019-25704" }, { "db": "JVNDB", "id": "JVNDB-2019-007725" }, { "db": "NVD", "id": "CVE-2019-12257" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:netapp:e-series_santricity_os_controller", "vulnerable": true }, { "cpe22Uri": "cpe:/o:sonicwall:sonicos", "vulnerable": true }, { "cpe22Uri": "cpe:/o:windriver:vxworks", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:siprotec_5_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-007725" } ] }, "cve": "CVE-2019-12257", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CVE-2019-12257", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 6.5, "id": "CNVD-2019-25704", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 6.5, "id": "93543796-4304-43f2-9d14-11a08f3135cc", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "VHN-143985", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:A/AC:L/AU:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2019-12257", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2019-12257", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2019-12257", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2019-12257", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2019-25704", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201907-1498", "trust": 0.6, "value": "HIGH" }, { "author": "IVD", "id": "93543796-4304-43f2-9d14-11a08f3135cc", "trust": 0.2, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-143985", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "IVD", "id": "93543796-4304-43f2-9d14-11a08f3135cc" }, { "db": "CNVD", "id": "CNVD-2019-25704" }, { "db": "VULHUB", "id": "VHN-143985" }, { "db": "JVNDB", "id": "JVNDB-2019-007725" }, { "db": "CNNVD", "id": "CNNVD-201907-1498" }, { "db": "NVD", "id": "CVE-2019-12257" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Wind River VxWorks 6.6 through 6.9 has a Buffer Overflow in the DHCP client component. There is an IPNET security vulnerability: Heap overflow in DHCP Offer/ACK parsing inside ipdhcpc. Wind River VxWorks Contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Wind River Systems VxWorks is an embedded real-time operating system (RTOS) from Wind River Systems. An attacker could exploit the vulnerability to overwrite the heap and execute code. The following products and versions are affected: Wind River Systems VxWorks Version 6.9, Version 6.8, Version 6.7, Version 6.6", "sources": [ { "db": "NVD", "id": "CVE-2019-12257" }, { "db": "JVNDB", "id": "JVNDB-2019-007725" }, { "db": "CNVD", "id": "CNVD-2019-25704" }, { "db": "IVD", "id": "93543796-4304-43f2-9d14-11a08f3135cc" }, { "db": "VULHUB", "id": "VHN-143985" } ], "trust": 2.43 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2019-12257", "trust": 3.3 }, { "db": "SIEMENS", "id": "SSA-189842", "trust": 1.7 }, { "db": "SIEMENS", "id": "SSA-632562", "trust": 1.7 }, { "db": "ICS CERT", "id": "ICSA-19-274-01", "trust": 1.4 }, { "db": "ICS CERT", "id": "ICSMA-19-274-01", "trust": 1.4 }, { "db": "ICS CERT", "id": "ICSA-19-211-01", "trust": 1.4 }, { "db": "CNNVD", "id": "CNNVD-201907-1498", "trust": 0.9 }, { "db": "CNVD", "id": "CNVD-2019-25704", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2019-007725", "trust": 0.8 }, { "db": "AUSCERT", "id": "ESB-2019.3695.5", "trust": 0.6 }, { "db": "AUSCERT", "id": "ASB-2019.0224", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2019.3245", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2019.2856", "trust": 0.6 }, { "db": "IVD", "id": "93543796-4304-43F2-9D14-11A08F3135CC", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-143985", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "93543796-4304-43f2-9d14-11a08f3135cc" }, { "db": "CNVD", "id": "CNVD-2019-25704" }, { "db": "VULHUB", "id": "VHN-143985" }, { "db": "JVNDB", "id": "JVNDB-2019-007725" }, { "db": "CNNVD", "id": "CNNVD-201907-1498" }, { "db": "NVD", "id": "CVE-2019-12257" } ] }, "id": "VAR-201908-0714", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "93543796-4304-43f2-9d14-11a08f3135cc" }, { "db": "CNVD", "id": "CNVD-2019-25704" }, { "db": "VULHUB", "id": "VHN-143985" } ], "trust": 1.4289024700000001 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.8 } ], "sources": [ { "db": "IVD", "id": "93543796-4304-43f2-9d14-11a08f3135cc" }, { "db": "CNVD", "id": "CNVD-2019-25704" } ] }, "last_update_date": "2024-11-23T19:56:36.606000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "NTAP-20190802-0001", "trust": 0.8, "url": "https://security.netapp.com/advisory/ntap-20190802-0001/" }, { "title": "SSA-632562", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-632562.pdf" }, { "title": "SNWLID-2019-0009", "trust": 0.8, "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2019-0009" }, { "title": "SECURITY VULNERABILITY RESPONSE INFORMATION", "trust": 0.8, "url": "https://www.windriver.com/security/announcements/tcp-ip-network-stack-ipnet-urgent11/" }, { "title": "CVE-2019-12257", "trust": 0.8, "url": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2019-12257" }, { "title": "Security Notices", "trust": 0.8, "url": "https://support2.windriver.com/index.php?page=security-notices" }, { "title": "Patch for Wind River Systems VxWorks Buffer Overflow Vulnerability (CNVD-2019-25704)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/172945" }, { "title": "Wind River Systems VxWorks Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=95613" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-25704" }, { "db": "JVNDB", "id": "JVNDB-2019-007725" }, { "db": "CNNVD", "id": "CNNVD-201907-1498" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-120", "trust": 1.0 }, { "problemtype": "CWE-119", "trust": 0.9 }, { "problemtype": "CWE-787", "trust": 0.1 } ], "sources": [ { "db": "VULHUB", "id": "VHN-143985" }, { "db": "JVNDB", "id": "JVNDB-2019-007725" }, { "db": "NVD", "id": "CVE-2019-12257" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.3, "url": "https://www.windriver.com/security/announcements/tcp-ip-network-stack-ipnet-urgent11/" }, { "trust": 2.2, "url": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=cve-2019-12257" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-189842.pdf" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-632562.pdf" }, { "trust": 1.7, "url": "https://psirt.global.sonicwall.com/vuln-detail/snwlid-2019-0009" }, { "trust": 1.7, "url": "https://security.netapp.com/advisory/ntap-20190802-0001/" }, { "trust": 1.7, "url": "https://support.f5.com/csp/article/k41190253" }, { "trust": 1.7, "url": "https://support2.windriver.com/index.php?page=security-notices" }, { "trust": 1.4, "url": "https://www.us-cert.gov/ics/advisories/icsa-19-274-01" }, { "trust": 1.4, "url": "https://www.us-cert.gov/ics/advisories/icsma-19-274-01" }, { "trust": 1.4, "url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-01" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-12257" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-12257" }, { "trust": 0.6, "url": "https://www.windriver.com/security/announcements/tcp-ip-network-stack-ipnet-urgent11/security-advisory-ipnet/security-advisory-ipnet.pdf" }, { "trust": 0.6, "url": "https://www.tenable.com/blog/critical-vulnerabilities-dubbed-urgent11-place-devices-running-vxworks-at-risk-of-rce-attacks" }, { "trust": 0.6, "url": "https://fortiguard.com/psirt/fg-ir-19-222" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2019.3695.5/" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2019.2856/" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/wind-river-vxworks-multiple-vulnerabilities-via-ipnet-29905" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/asb-2019.0224/" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2019.3245/" }, { "trust": 0.1, "url": "https://support2.windriver.com/index.php?page=cve\u0026amp;on=view\u0026amp;id=cve-2019-12257" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-25704" }, { "db": "VULHUB", "id": "VHN-143985" }, { "db": "JVNDB", "id": "JVNDB-2019-007725" }, { "db": "CNNVD", "id": "CNNVD-201907-1498" }, { "db": "NVD", "id": "CVE-2019-12257" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "93543796-4304-43f2-9d14-11a08f3135cc" }, { "db": "CNVD", "id": "CNVD-2019-25704" }, { "db": "VULHUB", "id": "VHN-143985" }, { "db": "JVNDB", "id": "JVNDB-2019-007725" }, { "db": "CNNVD", "id": "CNNVD-201907-1498" }, { "db": "NVD", "id": "CVE-2019-12257" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-08-02T00:00:00", "db": "IVD", "id": "93543796-4304-43f2-9d14-11a08f3135cc" }, { "date": "2019-08-02T00:00:00", "db": "CNVD", "id": "CNVD-2019-25704" }, { "date": "2019-08-09T00:00:00", "db": "VULHUB", "id": "VHN-143985" }, { "date": "2019-08-20T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-007725" }, { "date": "2019-07-29T00:00:00", "db": "CNNVD", "id": "CNNVD-201907-1498" }, { "date": "2019-08-09T18:15:11.320000", "db": "NVD", "id": "CVE-2019-12257" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-08-02T00:00:00", "db": "CNVD", "id": "CNVD-2019-25704" }, { "date": "2020-08-24T00:00:00", "db": "VULHUB", "id": "VHN-143985" }, { "date": "2019-10-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-007725" }, { "date": "2022-03-10T00:00:00", "db": "CNNVD", "id": "CNNVD-201907-1498" }, { "date": "2024-11-21T04:22:30.007000", "db": "NVD", "id": "CVE-2019-12257" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-201907-1498" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Wind River VxWorks Buffer error vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-007725" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Buffer error", "sources": [ { "db": "IVD", "id": "93543796-4304-43f2-9d14-11a08f3135cc" }, { "db": "CNNVD", "id": "CNNVD-201907-1498" } ], "trust": 0.8 } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.