var-201906-0328
Vulnerability from variot

Fuji Electric V-Server before 6.0.33.0 stores database credentials in project files as plaintext. An attacker that can gain access to the project file can recover the database credentials and gain access to the database server. Fuji Electric V-Server Contains vulnerabilities related to certificate and password management.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Fuji Electric V-Server is prone to multiple security vulnerabilities: 1. A remote denial-of-service vulnerability 2. An information disclosure vulnerability An attacker can exploit these issues to cause a denial-of-service condition or obtain sensitive information that may lead to further attacks . Versions prior to V-SFT 6.0.33.0 are vulnerable

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201906-0328",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "v-server",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "6.0.33.0"
      },
      {
        "model": "v-server",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "fuji electric",
        "version": "6.0.33.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.9.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.8.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.7.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.6.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.5.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.4.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.32.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.31.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.30.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.3.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.29.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.28.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.27.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.26.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.25.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.24.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.23.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.22.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.21.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.20.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.2.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.19.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.18.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.17.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.16.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.15.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.14.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.13.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.12.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.11.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.10.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.33.0"
      }
    ],
    "sources": [
      {
        "db": "BID",
        "id": "108740"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005462"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-3947"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:fujielectric:v-server",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005462"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenable",
    "sources": [
      {
        "db": "BID",
        "id": "108740"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201906-558"
      }
    ],
    "trust": 0.9
  },
  "cve": "CVE-2019-3947",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2019-3947",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.9,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2019-3947",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2019-3947",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2019-3947",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201906-558",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULMON",
            "id": "CVE-2019-3947",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2019-3947"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005462"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201906-558"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-3947"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Fuji Electric V-Server before 6.0.33.0 stores database credentials in project files as plaintext. An attacker that can gain access to the project file can recover the database credentials and gain access to the database server. Fuji Electric V-Server Contains vulnerabilities related to certificate and password management.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Fuji Electric V-Server is prone to multiple security vulnerabilities:\n1. A remote denial-of-service vulnerability\n2. An information disclosure vulnerability\nAn attacker can exploit these issues to cause a denial-of-service condition or obtain sensitive information that may lead to further attacks . \nVersions prior to V-SFT 6.0.33.0 are vulnerable",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-3947"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005462"
      },
      {
        "db": "BID",
        "id": "108740"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-3947"
      }
    ],
    "trust": 1.98
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "TENABLE",
        "id": "TRA-2019-27",
        "trust": 2.8
      },
      {
        "db": "NVD",
        "id": "CVE-2019-3947",
        "trust": 2.8
      },
      {
        "db": "BID",
        "id": "108740",
        "trust": 2.0
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005462",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201906-558",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-3947",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2019-3947"
      },
      {
        "db": "BID",
        "id": "108740"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005462"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201906-558"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-3947"
      }
    ]
  },
  "id": "VAR-201906-0328",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.65
  },
  "last_update_date": "2024-11-23T22:33:54.379000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "V-Server",
        "trust": 0.8,
        "url": "https://monitouch.fujielectric.com/site/tellus-e/tellus03-01.html"
      },
      {
        "title": "Fuji Electric V-Server Repair measures for trust management problem vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=93790"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005462"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201906-558"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-522",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-255",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005462"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-3947"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.8,
        "url": "https://www.tenable.com/security/research/tra-2019-27"
      },
      {
        "trust": 1.8,
        "url": "http://www.securityfocus.com/bid/108740"
      },
      {
        "trust": 0.9,
        "url": "http://www.fujielectric.com/"
      },
      {
        "trust": 0.9,
        "url": "https://monitouch.fujielectric.com/site/support-e/more-index-t.html"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-3947"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-3947"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/522.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2019-3947"
      },
      {
        "db": "BID",
        "id": "108740"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005462"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201906-558"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-3947"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULMON",
        "id": "CVE-2019-3947"
      },
      {
        "db": "BID",
        "id": "108740"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005462"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201906-558"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-3947"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-06-12T00:00:00",
        "db": "VULMON",
        "id": "CVE-2019-3947"
      },
      {
        "date": "2019-06-11T00:00:00",
        "db": "BID",
        "id": "108740"
      },
      {
        "date": "2019-06-20T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-005462"
      },
      {
        "date": "2019-06-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201906-558"
      },
      {
        "date": "2019-06-12T15:29:00.910000",
        "db": "NVD",
        "id": "CVE-2019-3947"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-08-24T00:00:00",
        "db": "VULMON",
        "id": "CVE-2019-3947"
      },
      {
        "date": "2019-06-11T00:00:00",
        "db": "BID",
        "id": "108740"
      },
      {
        "date": "2019-06-20T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-005462"
      },
      {
        "date": "2020-08-25T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201906-558"
      },
      {
        "date": "2024-11-21T04:42:55.407000",
        "db": "NVD",
        "id": "CVE-2019-3947"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201906-558"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Fuji Electric V-Server Vulnerabilities related to certificate and password management",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005462"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "trust management problem",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201906-558"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…