VT-Designer Version 2.1.7.31 is vulnerable by the program populating objects with user supplied input via a file without first checking for validity, allowing attacker supplied input to be written to known memory locations. This may cause the program to crash or allow remote code execution. VT-Designer Contains a vulnerability in the deserialization of unreliable data.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the handling of CArchive objects. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of the current process. INVT Electric VT-Designer is a graphics development tool from China's INVT Electric Company. A vulnerability exists in the INVT Electric VT-Designer version 2.1.7.31. Failed exploit attempts will likely result in denial-of-service conditions

Show details on source website


{
  "affected_products": {
    "_id": null,
    "data": [
      {
        "_id": null,
        "model": "vt-designer",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "invt",
        "version": "2.1.7.31"
      },
      {
        "_id": null,
        "model": "electric vt-designer",
        "scope": "eq",
        "trust": 0.9,
        "vendor": "invt",
        "version": "2.1.7.31"
      },
      {
        "_id": null,
        "model": "vt designer",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "invt electric",
        "version": "2.1.7.31"
      },
      {
        "_id": null,
        "model": "vt-designer",
        "scope": null,
        "trust": 0.7,
        "vendor": "invt",
        "version": null
      },
      {
        "_id": null,
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "vt designer",
        "version": "2.1.7.31"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d705aae-463f-11e9-82c7-000c29342cb1"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1361"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-24485"
      },
      {
        "db": "BID",
        "id": "106071"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-012627"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-915"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18987"
      }
    ]
  },
  "configurations": {
    "_id": null,
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:invt:vt-designer",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-012627"
      }
    ]
  },
  "credits": {
    "_id": null,
    "data": "Ariele Caltabiano (kimiya)",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-18-1361"
      }
    ],
    "trust": 0.7
  },
  "cve": "CVE-2018-18987",
  "cvss": {
    "_id": null,
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CVE-2018-18987",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 2.5,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2018-24485",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "7d705aae-463f-11e9-82c7-000c29342cb1",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.9 [IVD]"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2018-18987",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-18987",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-18987",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "ZDI",
            "id": "CVE-2018-18987",
            "trust": 0.7,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2018-24485",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201811-915",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "IVD",
            "id": "7d705aae-463f-11e9-82c7-000c29342cb1",
            "trust": 0.2,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d705aae-463f-11e9-82c7-000c29342cb1"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1361"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-24485"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-012627"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-915"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18987"
      }
    ]
  },
  "description": {
    "_id": null,
    "data": "VT-Designer Version 2.1.7.31 is vulnerable by the program populating objects with user supplied input via a file without first checking for validity, allowing attacker supplied input to be written to known memory locations. This may cause the program to crash or allow remote code execution. VT-Designer Contains a vulnerability in the deserialization of unreliable data.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the handling of CArchive objects. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of the current process. INVT Electric VT-Designer is a graphics development tool from China\u0027s INVT Electric Company. A vulnerability exists in the INVT Electric VT-Designer version 2.1.7.31. Failed exploit attempts will likely result in denial-of-service conditions",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-18987"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-012627"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1361"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-24485"
      },
      {
        "db": "BID",
        "id": "106071"
      },
      {
        "db": "IVD",
        "id": "7d705aae-463f-11e9-82c7-000c29342cb1"
      }
    ],
    "trust": 3.24
  },
  "external_ids": {
    "_id": null,
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-18987",
        "trust": 4.2
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-18-333-01",
        "trust": 3.3
      },
      {
        "db": "BID",
        "id": "106071",
        "trust": 1.3
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-24485",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-915",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-012627",
        "trust": 0.8
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-6428",
        "trust": 0.7
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1361",
        "trust": 0.7
      },
      {
        "db": "IVD",
        "id": "7D705AAE-463F-11E9-82C7-000C29342CB1",
        "trust": 0.2
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d705aae-463f-11e9-82c7-000c29342cb1"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1361"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-24485"
      },
      {
        "db": "BID",
        "id": "106071"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-012627"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-915"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18987"
      }
    ]
  },
  "id": "VAR-201811-0350",
  "iot": {
    "_id": null,
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "7d705aae-463f-11e9-82c7-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-24485"
      }
    ],
    "trust": 1.65416665
  },
  "iot_taxonomy": {
    "_id": null,
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d705aae-463f-11e9-82c7-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-24485"
      }
    ]
  },
  "last_update_date": "2024-11-23T21:38:02.313000Z",
  "patch": {
    "_id": null,
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.invt.com/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-012627"
      }
    ]
  },
  "problemtype_data": {
    "_id": null,
    "data": [
      {
        "problemtype": "CWE-502",
        "trust": 1.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-012627"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18987"
      }
    ]
  },
  "references": {
    "_id": null,
    "data": [
      {
        "trust": 3.3,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-333-01"
      },
      {
        "trust": 1.0,
        "url": "http://www.securityfocus.com/bid/106071"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18987"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-18987"
      },
      {
        "trust": 0.3,
        "url": "https://www.invt.com/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-24485"
      },
      {
        "db": "BID",
        "id": "106071"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-012627"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-915"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18987"
      }
    ]
  },
  "sources": {
    "_id": null,
    "data": [
      {
        "db": "IVD",
        "id": "7d705aae-463f-11e9-82c7-000c29342cb1",
        "ident": null
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1361",
        "ident": null
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-24485",
        "ident": null
      },
      {
        "db": "BID",
        "id": "106071",
        "ident": null
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-012627",
        "ident": null
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-915",
        "ident": null
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18987",
        "ident": null
      }
    ]
  },
  "sources_release_date": {
    "_id": null,
    "data": [
      {
        "date": "2018-12-04T00:00:00",
        "db": "IVD",
        "id": "7d705aae-463f-11e9-82c7-000c29342cb1",
        "ident": null
      },
      {
        "date": "2018-11-26T00:00:00",
        "db": "ZDI",
        "id": "ZDI-18-1361",
        "ident": null
      },
      {
        "date": "2018-12-03T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-24485",
        "ident": null
      },
      {
        "date": "2018-12-05T00:00:00",
        "db": "BID",
        "id": "106071",
        "ident": null
      },
      {
        "date": "2019-02-06T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-012627",
        "ident": null
      },
      {
        "date": "2018-11-30T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201811-915",
        "ident": null
      },
      {
        "date": "2018-11-30T18:29:00.537000",
        "db": "NVD",
        "id": "CVE-2018-18987",
        "ident": null
      }
    ]
  },
  "sources_update_date": {
    "_id": null,
    "data": [
      {
        "date": "2018-11-29T00:00:00",
        "db": "ZDI",
        "id": "ZDI-18-1361",
        "ident": null
      },
      {
        "date": "2018-12-04T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-24485",
        "ident": null
      },
      {
        "date": "2018-12-05T00:00:00",
        "db": "BID",
        "id": "106071",
        "ident": null
      },
      {
        "date": "2019-02-06T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-012627",
        "ident": null
      },
      {
        "date": "2018-12-03T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201811-915",
        "ident": null
      },
      {
        "date": "2024-11-21T03:56:59.507000",
        "db": "NVD",
        "id": "CVE-2018-18987",
        "ident": null
      }
    ]
  },
  "threat_type": {
    "_id": null,
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-915"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "_id": null,
    "data": "INVT Electric VT-Designer Code execution vulnerability",
    "sources": [
      {
        "db": "IVD",
        "id": "7d705aae-463f-11e9-82c7-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-24485"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "_id": null,
    "data": "lack of information",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-915"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…