var-201810-0621
Vulnerability from variot
A vulnerability in the web interface for specific feature sets of Cisco Integrated Management Controller (IMC) Supervisor and Cisco UCS Director could allow an authenticated, remote attacker to access sensitive information. The vulnerability is due to an authorization check that does not properly include the access level of the web interface user. An attacker who has valid application credentials could exploit this vulnerability by sending a crafted HTTP request to the web interface. A successful exploit could allow the attacker to view sensitive information that belongs to other users. The attacker could then use this information to conduct additional reconnaissance attacks. Multiple Cisco Products are prone to an information-disclosure vulnerability. This issue is being tracked by Cisco Bug IDs CSCvj95420 and CSCvk10260. UCS Director Software is a converged infrastructure management solution
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0621", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ucs director", "scope": "eq", "trust": 1.6, "vendor": "cisco", "version": "6.6\\(1.0\\)" }, { "model": "ucs director", "scope": "eq", "trust": 1.6, "vendor": "cisco", "version": "2.1\\(0.0\\)" }, { "model": "ucs director", "scope": null, "trust": 0.8, "vendor": "cisco", "version": null }, { "model": "ucs director", "scope": "eq", "trust": 0.3, "vendor": "cisco", "version": "0" }, { "model": "integrated management controller supervisor software", "scope": "eq", "trust": 0.3, "vendor": "cisco", "version": "0" } ], "sources": [ { "db": "BID", "id": "105708" }, { "db": "JVNDB", "id": "JVNDB-2018-013489" }, { "db": "CNNVD", "id": "CNNVD-201810-196" }, { "db": "NVD", "id": "CVE-2018-15405" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/a:cisco:ucs_director", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-013489" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Cisco", "sources": [ { "db": "BID", "id": "105708" } ], "trust": 0.3 }, "cve": "CVE-2018-15405", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 4.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "id": "CVE-2018-15405", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "VULHUB", "availabilityImpact": "NONE", "baseScore": 4.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "id": "VHN-125661", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:S/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2018-15405", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 6.5, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2018-15405", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2018-15405", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "CVE-2018-15405", "trust": 0.8, "value": "Medium" }, { "author": "CNNVD", "id": "CNNVD-201810-196", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULHUB", "id": "VHN-125661", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULHUB", "id": "VHN-125661" }, { "db": "JVNDB", "id": "JVNDB-2018-013489" }, { "db": "CNNVD", "id": "CNNVD-201810-196" }, { "db": "NVD", "id": "CVE-2018-15405" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability in the web interface for specific feature sets of Cisco Integrated Management Controller (IMC) Supervisor and Cisco UCS Director could allow an authenticated, remote attacker to access sensitive information. The vulnerability is due to an authorization check that does not properly include the access level of the web interface user. An attacker who has valid application credentials could exploit this vulnerability by sending a crafted HTTP request to the web interface. A successful exploit could allow the attacker to view sensitive information that belongs to other users. The attacker could then use this information to conduct additional reconnaissance attacks. Multiple Cisco Products are prone to an information-disclosure vulnerability. \nThis issue is being tracked by Cisco Bug IDs CSCvj95420 and CSCvk10260. UCS Director Software is a converged infrastructure management solution", "sources": [ { "db": "NVD", "id": "CVE-2018-15405" }, { "db": "JVNDB", "id": "JVNDB-2018-013489" }, { "db": "BID", "id": "105708" }, { "db": "VULHUB", "id": "VHN-125661" } ], "trust": 1.98 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2018-15405", "trust": 2.8 }, { "db": "SECTRACK", "id": "1041779", "trust": 1.7 }, { "db": "JVNDB", "id": "JVNDB-2018-013489", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201810-196", "trust": 0.7 }, { "db": "BID", "id": "105708", "trust": 0.3 }, { "db": "VULHUB", "id": "VHN-125661", "trust": 0.1 } ], "sources": [ { "db": "VULHUB", "id": "VHN-125661" }, { "db": "BID", "id": "105708" }, { "db": "JVNDB", "id": "JVNDB-2018-013489" }, { "db": "CNNVD", "id": "CNNVD-201810-196" }, { "db": "NVD", "id": "CVE-2018-15405" } ] }, "id": "VAR-201810-0621", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-125661" } ], "trust": 0.01 }, "last_update_date": "2024-11-23T23:02:00.354000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "cisco-sa-20181003-imcs-ucsd-id", "trust": 0.8, "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20181003-imcs-ucsd-id" }, { "title": "Cisco Integrated Management Controller Supervisor and Director Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=85410" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-013489" }, { "db": "CNNVD", "id": "CNNVD-201810-196" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-863", "trust": 1.1 }, { "problemtype": "CWE-285", "trust": 1.0 }, { "problemtype": "CWE-200", "trust": 0.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-125661" }, { "db": "JVNDB", "id": "JVNDB-2018-013489" }, { "db": "NVD", "id": "CVE-2018-15405" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-20181003-imcs-ucsd-id" }, { "trust": 1.7, "url": "http://www.securitytracker.com/id/1041779" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-15405" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-15405" }, { "trust": 0.3, "url": "http://www.cisco.com/" } ], "sources": [ { "db": "VULHUB", "id": "VHN-125661" }, { "db": "BID", "id": "105708" }, { "db": "JVNDB", "id": "JVNDB-2018-013489" }, { "db": "CNNVD", "id": "CNNVD-201810-196" }, { "db": "NVD", "id": "CVE-2018-15405" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULHUB", "id": "VHN-125661" }, { "db": "BID", "id": "105708" }, { "db": "JVNDB", "id": "JVNDB-2018-013489" }, { "db": "CNNVD", "id": "CNNVD-201810-196" }, { "db": "NVD", "id": "CVE-2018-15405" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2018-10-05T00:00:00", "db": "VULHUB", "id": "VHN-125661" }, { "date": "2018-10-03T00:00:00", "db": "BID", "id": "105708" }, { "date": "2019-02-21T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-013489" }, { "date": "2018-10-08T00:00:00", "db": "CNNVD", "id": "CNNVD-201810-196" }, { "date": "2018-10-05T14:29:08.903000", "db": "NVD", "id": "CVE-2018-15405" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-08-31T00:00:00", "db": "VULHUB", "id": "VHN-125661" }, { "date": "2018-10-03T00:00:00", "db": "BID", "id": "105708" }, { "date": "2019-02-21T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-013489" }, { "date": "2020-10-22T00:00:00", "db": "CNNVD", "id": "CNNVD-201810-196" }, { "date": "2024-11-21T03:50:43.180000", "db": "NVD", "id": "CVE-2018-15405" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201810-196" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Cisco Integrated Management Controller Supervisor and UCS Director Vulnerable to information disclosure", "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-013489" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "information disclosure", "sources": [ { "db": "CNNVD", "id": "CNNVD-201810-196" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.