var-201810-0128
Vulnerability from variot

Advantech WebAccess 8.3.2 and below is vulnerable to a stack buffer overflow vulnerability. A remote authenticated attacker could potentially exploit this vulnerability by sending a crafted HTTP request to broadweb/system/opcImg.asp. Advantech WebAccess Contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Advantech WebAccess is a suite of browser-based HMI/SCADA software from Advantech. The software supports dynamic graphical display and real-time data control, and provides the ability to remotely control and manage automation equipment

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0128",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "webaccess",
        "scope": "lte",
        "trust": 1.8,
        "vendor": "advantech",
        "version": "8.3.2"
      },
      {
        "model": "webaccess",
        "scope": "lte",
        "trust": 0.6,
        "vendor": "advantech",
        "version": "\u003c=8.3.2"
      },
      {
        "model": "webaccess",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "advantech",
        "version": "8.3.2"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "webaccess",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2fe7ab1-39ab-11e9-8710-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-21797"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011103"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1121"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-15704"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:advantech:webaccess",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011103"
      }
    ]
  },
  "cve": "CVE-2018-15704",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CVE-2018-15704",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2018-21797",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "e2fe7ab1-39ab-11e9-8710-000c29342cb1",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "VHN-125990",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2018-15704",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-15704",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-15704",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2018-21797",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201810-1121",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "IVD",
            "id": "e2fe7ab1-39ab-11e9-8710-000c29342cb1",
            "trust": 0.2,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-125990",
            "trust": 0.1,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2018-15704",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2fe7ab1-39ab-11e9-8710-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-21797"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125990"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-15704"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011103"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1121"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-15704"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Advantech WebAccess 8.3.2 and below is vulnerable to a stack buffer overflow vulnerability. A remote authenticated attacker could potentially exploit this vulnerability by sending a crafted HTTP request to broadweb/system/opcImg.asp. Advantech WebAccess Contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Advantech WebAccess is a suite of browser-based HMI/SCADA software from Advantech. The software supports dynamic graphical display and real-time data control, and provides the ability to remotely control and manage automation equipment",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-15704"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011103"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-21797"
      },
      {
        "db": "IVD",
        "id": "e2fe7ab1-39ab-11e9-8710-000c29342cb1"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125990"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-15704"
      }
    ],
    "trust": 2.52
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-15704",
        "trust": 3.4
      },
      {
        "db": "TENABLE",
        "id": "TRA-2018-33",
        "trust": 2.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1121",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-21797",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011103",
        "trust": 0.8
      },
      {
        "db": "IVD",
        "id": "E2FE7AB1-39AB-11E9-8710-000C29342CB1",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-125990",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-15704",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2fe7ab1-39ab-11e9-8710-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-21797"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125990"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-15704"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011103"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1121"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-15704"
      }
    ]
  },
  "id": "VAR-201810-0128",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "e2fe7ab1-39ab-11e9-8710-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-21797"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125990"
      }
    ],
    "trust": 1.33470696
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2fe7ab1-39ab-11e9-8710-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-21797"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:17:17.884000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Advantech WebAccess",
        "trust": 0.8,
        "url": "http://www.advantech.com/industrial-automation/webaccess/webaccessscada"
      },
      {
        "title": "Check Point Security Alerts: Advantech WebAccess Buffer Overflow (CVE-2018-15704)",
        "trust": 0.1,
        "url": "https://vulmon.com/vendoradvisory?qidtp=check_point_security_alerts\u0026qid=ead700aab13b40fd4fe05b6f6af7e21e"
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2018-15704"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011103"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.1
      },
      {
        "problemtype": "CWE-119",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-125990"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011103"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-15704"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.6,
        "url": "https://www.tenable.com/security/research/tra-2018-33"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-15704"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-15704"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/787.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://advisories.checkpoint.com/defense/advisories/public/2024/cpai-2018-2677.html"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-21797"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125990"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-15704"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011103"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1121"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-15704"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "e2fe7ab1-39ab-11e9-8710-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-21797"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125990"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-15704"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011103"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1121"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-15704"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-10-26T00:00:00",
        "db": "IVD",
        "id": "e2fe7ab1-39ab-11e9-8710-000c29342cb1"
      },
      {
        "date": "2018-10-25T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-21797"
      },
      {
        "date": "2018-10-22T00:00:00",
        "db": "VULHUB",
        "id": "VHN-125990"
      },
      {
        "date": "2018-10-22T00:00:00",
        "db": "VULMON",
        "id": "CVE-2018-15704"
      },
      {
        "date": "2019-01-07T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-011103"
      },
      {
        "date": "2018-10-23T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1121"
      },
      {
        "date": "2018-10-22T19:29:00.453000",
        "db": "NVD",
        "id": "CVE-2018-15704"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-10-26T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-21797"
      },
      {
        "date": "2020-08-24T00:00:00",
        "db": "VULHUB",
        "id": "VHN-125990"
      },
      {
        "date": "2020-08-24T00:00:00",
        "db": "VULMON",
        "id": "CVE-2018-15704"
      },
      {
        "date": "2019-01-07T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-011103"
      },
      {
        "date": "2020-08-25T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1121"
      },
      {
        "date": "2024-11-21T03:51:18.577000",
        "db": "NVD",
        "id": "CVE-2018-15704"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1121"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Advantech WebAccess Buffer error vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011103"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1121"
      }
    ],
    "trust": 1.4
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1121"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.