var-201809-1099
Vulnerability from variot
For some Iomega, Lenovo, LenovoEMC NAS devices versions 4.1.402.34662 and earlier, the file name used for assets accessible through the Content Viewer application are vulnerable to self cross-site scripting self-XSS. As a result, adversaries can add files to shares accessible from the Content Viewer with a cross site scripting payload in its name, and wait for a user to try and rename the file for their payload to trigger. Iomega , Lenovo , LenovoEMC NAS The device contains a cross-site scripting vulnerability.Information may be obtained and information may be altered. Lenovo Iomega StorCenter px12-450r and others are all storage devices of China Lenovo (Lenovo). A cross-site scripting vulnerability exists in the Web UI of several Lenovo products using firmware 4.1.402.34662 and earlier. A remote attacker could exploit this vulnerability to elevate privileges by adding a file. The following products and versions are affected: Lenovo Iomega StorCenter px12-450r, StorCenter px12-400r, StorCenter px4-300r, StorCenter px6-300d, StorCenter px4-300d, StorCenter px2-300d, StorCenter ix4-300d, StorCenter ix2/ix2-dl , EZ Media & Backup Center; LenovoEMC px12-450r, px12-400r, px4-400r, px4-300r, px6-300d, px4-400d, px4-300d, px2-300d; Lenovo ix4-300d, ix2, EZ Media & Backup Center
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201809-1099", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "storcenter px12-400r", "scope": "eq", "trust": 1.6, "vendor": "lenovo", "version": "4.1.402.34662" }, { "model": "storcenter px4-300r", "scope": "eq", "trust": 1.6, "vendor": "lenovo", "version": "4.1.402.34662" }, { "model": "storcenter px2-300d", "scope": "eq", "trust": 1.6, "vendor": "lenovo", "version": "4.1.402.34662" }, { "model": "storcenter ix4-300d", "scope": "eq", "trust": 1.6, "vendor": "lenovo", "version": "4.1.402.34662" }, { "model": "storcenter px12-450r", "scope": "eq", "trust": 1.6, "vendor": "lenovo", "version": "4.1.402.34662" }, { "model": "storcenter px4-300d", "scope": "eq", "trust": 1.6, "vendor": "lenovo", "version": "4.1.402.34662" }, { "model": "ez media \\\u0026 backup center", "scope": "eq", "trust": 1.6, "vendor": "lenovo", "version": "4.1.402.34662" }, { "model": "storcenter px6-300d", "scope": "eq", "trust": 1.6, "vendor": "lenovo", "version": "4.1.402.34662" }, { "model": "storcenter ix2", "scope": "eq", "trust": 1.6, "vendor": "lenovo", "version": "4.1.402.34662" }, { "model": "storcenter ix2-dl", "scope": "eq", "trust": 1.6, "vendor": "lenovo", "version": "4.1.402.34662" }, { "model": "ix4-300d", "scope": "eq", "trust": 1.0, "vendor": "lenovo", "version": "4.1.402.34662" }, { "model": "px12-450r", "scope": "eq", "trust": 1.0, "vendor": "lenovo", "version": "4.1.402.34662" }, { "model": "px4-400r", "scope": "eq", "trust": 1.0, "vendor": "lenovo", "version": "4.1.402.34662" }, { "model": "px4-300d", "scope": "eq", "trust": 1.0, "vendor": "lenovo", "version": "4.1.402.34662" }, { "model": "px12-400r", "scope": "eq", "trust": 1.0, "vendor": "lenovo", "version": "4.1.402.34662" }, { "model": "px4-400d", "scope": "eq", "trust": 1.0, "vendor": "lenovo", "version": "4.1.402.34662" }, { "model": "ix2", "scope": "eq", "trust": 1.0, "vendor": "lenovo", "version": "4.1.402.34662" }, { "model": "px6-300d", "scope": "eq", "trust": 1.0, "vendor": "lenovo", "version": "4.1.402.34662" }, { "model": "px2-300d", "scope": "eq", "trust": 1.0, "vendor": "lenovo", "version": "4.1.402.34662" }, { "model": "px4-300r", "scope": "eq", "trust": 1.0, "vendor": "lenovo", "version": "4.1.402.34662" }, { "model": "lenovoemc", "scope": null, "trust": 0.8, "vendor": "lenovo", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-010432" }, { "db": "CNNVD", "id": "CNNVD-201809-1180" }, { "db": "NVD", "id": "CVE-2018-9081" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/a:lenovo:emc_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-010432" } ] }, "cve": "CVE-2018-9081", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "HIGH", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 2.6, "confidentialityImpact": "NONE", "exploitabilityScore": 4.9, "id": "CVE-2018-9081", "impactScore": 2.9, "integrityImpact": "PARTIAL", "severity": "LOW", "trust": 1.8, "vectorString": "AV:N/AC:H/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "accessComplexity": "HIGH", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "NONE", "baseScore": 2.6, "confidentialityImpact": "NONE", "exploitabilityScore": 4.9, "id": "VHN-139113", "impactScore": 2.9, "integrityImpact": "PARTIAL", "severity": "LOW", "trust": 0.1, "vectorString": "AV:N/AC:H/AU:N/C:N/I:P/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "HIGH", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 4.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 1.6, "id": "CVE-2018-9081", "impactScore": 2.7, "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.8, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2018-9081", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "CVE-2018-9081", "trust": 0.8, "value": "Medium" }, { "author": "CNNVD", "id": "CNNVD-201809-1180", "trust": 0.6, "value": "LOW" }, { "author": "VULHUB", "id": "VHN-139113", "trust": 0.1, "value": "LOW" } ] } ], "sources": [ { "db": "VULHUB", "id": "VHN-139113" }, { "db": "JVNDB", "id": "JVNDB-2018-010432" }, { "db": "CNNVD", "id": "CNNVD-201809-1180" }, { "db": "NVD", "id": "CVE-2018-9081" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "For some Iomega, Lenovo, LenovoEMC NAS devices versions 4.1.402.34662 and earlier, the file name used for assets accessible through the Content Viewer application are vulnerable to self cross-site scripting self-XSS. As a result, adversaries can add files to shares accessible from the Content Viewer with a cross site scripting payload in its name, and wait for a user to try and rename the file for their payload to trigger. Iomega , Lenovo , LenovoEMC NAS The device contains a cross-site scripting vulnerability.Information may be obtained and information may be altered. Lenovo Iomega StorCenter px12-450r and others are all storage devices of China Lenovo (Lenovo). A cross-site scripting vulnerability exists in the Web UI of several Lenovo products using firmware 4.1.402.34662 and earlier. A remote attacker could exploit this vulnerability to elevate privileges by adding a file. The following products and versions are affected: Lenovo Iomega StorCenter px12-450r, StorCenter px12-400r, StorCenter px4-300r, StorCenter px6-300d, StorCenter px4-300d, StorCenter px2-300d, StorCenter ix4-300d, StorCenter ix2/ix2-dl , EZ Media \u0026 Backup Center; LenovoEMC px12-450r, px12-400r, px4-400r, px4-300r, px6-300d, px4-400d, px4-300d, px2-300d; Lenovo ix4-300d, ix2, EZ Media \u0026 Backup Center", "sources": [ { "db": "NVD", "id": "CVE-2018-9081" }, { "db": "JVNDB", "id": "JVNDB-2018-010432" }, { "db": "VULHUB", "id": "VHN-139113" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2018-9081", "trust": 2.5 }, { "db": "LENOVO", "id": "LEN-24224", "trust": 1.7 }, { "db": "JVNDB", "id": "JVNDB-2018-010432", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201809-1180", "trust": 0.7 }, { "db": "VULHUB", "id": "VHN-139113", "trust": 0.1 } ], "sources": [ { "db": "VULHUB", "id": "VHN-139113" }, { "db": "JVNDB", "id": "JVNDB-2018-010432" }, { "db": "CNNVD", "id": "CNNVD-201809-1180" }, { "db": "NVD", "id": "CVE-2018-9081" } ] }, "id": "VAR-201809-1099", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-139113" } ], "trust": 0.01 }, "last_update_date": "2024-11-23T22:00:17.248000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "LEN-24224", "trust": 0.8, "url": "https://support.lenovo.com/jp/ja/solutions/len-24224" }, { "title": "Multiple Lenovo Product security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=85214" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-010432" }, { "db": "CNNVD", "id": "CNNVD-201809-1180" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-79", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-139113" }, { "db": "JVNDB", "id": "JVNDB-2018-010432" }, { "db": "NVD", "id": "CVE-2018-9081" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://support.lenovo.com/us/en/solutions/len-24224" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-9081" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-9081" } ], "sources": [ { "db": "VULHUB", "id": "VHN-139113" }, { "db": "JVNDB", "id": "JVNDB-2018-010432" }, { "db": "CNNVD", "id": "CNNVD-201809-1180" }, { "db": "NVD", "id": "CVE-2018-9081" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULHUB", "id": "VHN-139113" }, { "db": "JVNDB", "id": "JVNDB-2018-010432" }, { "db": "CNNVD", "id": "CNNVD-201809-1180" }, { "db": "NVD", "id": "CVE-2018-9081" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2018-09-28T00:00:00", "db": "VULHUB", "id": "VHN-139113" }, { "date": "2018-12-14T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-010432" }, { "date": "2018-09-27T00:00:00", "db": "CNNVD", "id": "CNNVD-201809-1180" }, { "date": "2018-09-28T20:29:01.423000", "db": "NVD", "id": "CVE-2018-9081" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2018-11-16T00:00:00", "db": "VULHUB", "id": "VHN-139113" }, { "date": "2018-12-14T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-010432" }, { "date": "2018-09-30T00:00:00", "db": "CNNVD", "id": "CNNVD-201809-1180" }, { "date": "2024-11-21T04:14:56.240000", "db": "NVD", "id": "CVE-2018-9081" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201809-1180" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Lenovo Product site cross-site scripting vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-010432" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "XSS", "sources": [ { "db": "CNNVD", "id": "CNNVD-201809-1180" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.