Vulnerability from variot
A potential remote denial of service security vulnerability has been identified in HPE Integrated Lights Out 4 prior to v2.60 and iLO 5 for Gen 10 servers prior to v1.30. HPE Integrated Lights Out 4 and iLO 5 Contains an input validation vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. HP Integrated Lights-Out is prone to an unspecified remote denial-of-service vulnerability. Exploiting this issue allows remote attackers to trigger denial-of-service conditions. Through an integrated remote management port, Monitor and maintain the running status of the server, remotely manage and control the server, etc. A remote attacker could exploit this vulnerability to cause a denial of service
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201809-1079", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "integrated lights-out 4", "scope": "lt", "trust": 1.0, "vendor": "hp", "version": "2.60" }, { "model": "integrated lights-out 5", "scope": "lt", "trust": 1.0, "vendor": "hp", "version": "1.30" }, { "model": "hpe integrated lights-out 4", "scope": "lt", "trust": 0.8, "vendor": "hewlett packard", "version": "2.60" }, { "model": "hpe integrated lights-out 5", "scope": "lt", "trust": 0.8, "vendor": "hewlett packard", "version": "1.30" }, { "model": "integrated lights-out 4", "scope": "eq", "trust": 0.6, "vendor": "hp", "version": "2.03" }, { "model": "integrated lights-out 4", "scope": "eq", "trust": 0.6, "vendor": "hp", "version": "1.13" }, { "model": "integrated lights-out 4", "scope": "eq", "trust": 0.6, "vendor": "hp", "version": "1.11" }, { "model": "integrated lights-out 4", "scope": "eq", "trust": 0.6, "vendor": "hp", "version": "1.20" }, { "model": "integrated lights-out 4", "scope": "eq", "trust": 0.6, "vendor": "hp", "version": "2.01" }, { "model": "integrated lights-out", "scope": "eq", "trust": 0.3, "vendor": "hp", "version": "51.11" }, { "model": "integrated lights-out", "scope": "eq", "trust": 0.3, "vendor": "hp", "version": "42.53" }, { "model": "integrated lights-out", "scope": "eq", "trust": 0.3, "vendor": "hp", "version": "42.50" }, { "model": "integrated lights-out", "scope": "eq", "trust": 0.3, "vendor": "hp", "version": "42.44" }, { "model": "integrated lights-out", "scope": "eq", "trust": 0.3, "vendor": "hp", "version": "42.22" }, { "model": "integrated lights-out", "scope": "eq", "trust": 0.3, "vendor": "hp", "version": "42.20" }, { "model": "integrated lights-out", "scope": "eq", "trust": 0.3, "vendor": "hp", "version": "42.03" }, { "model": "integrated lights-out", "scope": "eq", "trust": 0.3, "vendor": "hp", "version": "41.32" }, { "model": "integrated lights-out", "scope": "eq", "trust": 0.3, "vendor": "hp", "version": "41.30" }, { "model": "integrated lights-out", "scope": "eq", "trust": 0.3, "vendor": "hp", "version": "41.22" }, { "model": "integrated lights-out", "scope": "eq", "trust": 0.3, "vendor": "hp", "version": "41.13" }, { "model": "integrated lights-out", "scope": "eq", "trust": 0.3, "vendor": "hp", "version": "41.11" }, { "model": "integrated lights-out", "scope": "eq", "trust": 0.3, "vendor": "hp", "version": "42.10" }, { "model": "gen servers", "scope": "eq", "trust": 0.3, "vendor": "hp", "version": "100" }, { "model": "integrated lights-out", "scope": "ne", "trust": 0.3, "vendor": "hp", "version": "51.30" }, { "model": "integrated lights-out", "scope": "ne", "trust": 0.3, "vendor": "hp", "version": "42.60" } ], "sources": [ { "db": "BID", "id": "107298" }, { "db": "JVNDB", "id": "JVNDB-2018-010850" }, { "db": "CNNVD", "id": "CNNVD-201809-1234" }, { "db": "NVD", "id": "CVE-2018-7101" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:hp:integrated_lights-out_4_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:hp:integrated_lights-out_5_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-010850" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Matias Soler", "sources": [ { "db": "BID", "id": "107298" } ], "trust": 0.3 }, "cve": "CVE-2018-7101", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2018-7101", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "VHN-137133", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2018-7101", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.8, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2018-7101", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2018-7101", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-201809-1234", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-137133", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULHUB", "id": "VHN-137133" }, { "db": "JVNDB", "id": "JVNDB-2018-010850" }, { "db": "CNNVD", "id": "CNNVD-201809-1234" }, { "db": "NVD", "id": "CVE-2018-7101" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A potential remote denial of service security vulnerability has been identified in HPE Integrated Lights Out 4 prior to v2.60 and iLO 5 for Gen 10 servers prior to v1.30. HPE Integrated Lights Out 4 and iLO 5 Contains an input validation vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. HP Integrated Lights-Out is prone to an unspecified remote denial-of-service vulnerability. \nExploiting this issue allows remote attackers to trigger denial-of-service conditions. Through an integrated remote management port, Monitor and maintain the running status of the server, remotely manage and control the server, etc. A remote attacker could exploit this vulnerability to cause a denial of service", "sources": [ { "db": "NVD", "id": "CVE-2018-7101" }, { "db": "JVNDB", "id": "JVNDB-2018-010850" }, { "db": "BID", "id": "107298" }, { "db": "VULHUB", "id": "VHN-137133" } ], "trust": 1.98 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2018-7101", "trust": 2.8 }, { "db": "SECTRACK", "id": "1041488", "trust": 1.7 }, { "db": "JVNDB", "id": "JVNDB-2018-010850", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201809-1234", "trust": 0.7 }, { "db": "BID", "id": "107298", "trust": 0.3 }, { "db": "VULHUB", "id": "VHN-137133", "trust": 0.1 } ], "sources": [ { "db": "VULHUB", "id": "VHN-137133" }, { "db": "BID", "id": "107298" }, { "db": "JVNDB", "id": "JVNDB-2018-010850" }, { "db": "CNNVD", "id": "CNNVD-201809-1234" }, { "db": "NVD", "id": "CVE-2018-7101" } ] }, "id": "VAR-201809-1079", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-137133" } ], "trust": 0.01 }, "last_update_date": "2024-11-23T22:55:43.801000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "hpesbhf03875en_us", "trust": 0.8, "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03875en_us" }, { "title": "HPE Integrated Lights Out 4 and 5 for Gen Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=85250" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-010850" }, { "db": "CNNVD", "id": "CNNVD-201809-1234" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "CWE-20", "trust": 0.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-137133" }, { "db": "JVNDB", "id": "JVNDB-2018-010850" }, { "db": "NVD", "id": "CVE-2018-7101" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.9, "url": "https://support.hpe.com/hpsc/doc/public/display?doclocale=en_us\u0026docid=emr_na-hpesbhf03875en_us" }, { "trust": 1.7, "url": "http://www.securitytracker.com/id/1041488" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-7101" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-7101" }, { "trust": 0.3, "url": "http://www.hp.com/" }, { "trust": 0.1, "url": "https://support.hpe.com/hpsc/doc/public/display?doclocale=en_us\u0026amp;docid=emr_na-hpesbhf03875en_us" } ], "sources": [ { "db": "VULHUB", "id": "VHN-137133" }, { "db": "BID", "id": "107298" }, { "db": "JVNDB", "id": "JVNDB-2018-010850" }, { "db": "CNNVD", "id": "CNNVD-201809-1234" }, { "db": "NVD", "id": "CVE-2018-7101" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULHUB", "id": "VHN-137133" }, { "db": "BID", "id": "107298" }, { "db": "JVNDB", "id": "JVNDB-2018-010850" }, { "db": "CNNVD", "id": "CNNVD-201809-1234" }, { "db": "NVD", "id": "CVE-2018-7101" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2018-09-27T00:00:00", "db": "VULHUB", "id": "VHN-137133" }, { "date": "2018-08-14T00:00:00", "db": "BID", "id": "107298" }, { "date": "2018-12-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-010850" }, { "date": "2018-09-28T00:00:00", "db": "CNNVD", "id": "CNNVD-201809-1234" }, { "date": "2018-09-27T18:29:00.300000", "db": "NVD", "id": "CVE-2018-7101" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-08-24T00:00:00", "db": "VULHUB", "id": "VHN-137133" }, { "date": "2018-08-14T00:00:00", "db": "BID", "id": "107298" }, { "date": "2018-12-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-010850" }, { "date": "2020-10-22T00:00:00", "db": "CNNVD", "id": "CNNVD-201809-1234" }, { "date": "2024-11-21T04:11:38.753000", "db": "NVD", "id": "CVE-2018-7101" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201809-1234" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "HPE Integrated Lights Out 4 and iLO 5 Input validation vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-010850" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "input validation error", "sources": [ { "db": "CNNVD", "id": "CNNVD-201809-1234" } ], "trust": 0.6 } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.