var-201711-0630
Vulnerability from variot
Command Injection vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318)cn devices allows remote unauthenticated attackers to execute arbitrary OS commands via a crafted cgi-bin/luci/usbeject?dev_name= GET request from the LAN. This occurs because the "sub_A6E8 usbeject_process_entry" function executes a system function with untrusted input. Shenzhen Tenda Ac9 , Ac15 ,and Ac18 The device contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. ShenzhenTendaAc9 and other are the wireless router products of Tenda. App_data_center is one of the application data centers. There is a command injection vulnerability in app_data_center in several ShenzhenTenda products. The following versions are affected: Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01 Version, Ac9 ac9_kf_V15.03.05.19(6318)cn Version, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01 Version, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01 Version, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01 version, Ac18 ac18_kf_V15.03.05.19(6318)_cn devices version
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201711-0630", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac15", "scope": "eq", "trust": 2.4, "vendor": "tenda", "version": "us_ac15v1.0br_v15.03.05.18_multi_td01" }, { "model": "ac15", "scope": "eq", "trust": 2.4, "vendor": "tenda", "version": "us_ac15v1.0br_v15.03.05.19_multi_td01" }, { "model": "ac18", "scope": "eq", "trust": 2.4, "vendor": "tenda", "version": "us_ac18v1.0br_v15.03.05.05_multi_td01" }, { "model": "ac9", "scope": "eq", "trust": 2.4, "vendor": "tenda", "version": "us_ac9v1.0br_v15.03.05.14_multi_td01" }, { "model": "ac9", "scope": "eq", "trust": 1.6, "vendor": "tenda", "version": "ac9_kf_v15.03.05.19\\(6318_\\)_cn" }, { "model": "ac18", "scope": "eq", "trust": 1.6, "vendor": "tenda", "version": "ac18_kf_v15.03.05.19\\(6318_\\)_cn" }, { "model": "ac18", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac18_kf_v15.03.05.19(6318_)_cn" }, { "model": "ac9", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac9_kf_v15.03.05.19(6318_)_cn" }, { "model": "tenda technology co.,ltd. w15e devices", "scope": null, "trust": 0.6, "vendor": "", "version": null }, { "model": "tenda technology co.,ltd. ac9 us_ac9v1.0br_v15.03.05.14_multi_td01", "scope": null, "trust": 0.6, "vendor": "", "version": null }, { "model": "tenda technology co.,ltd. ac9 ac9_kf_v15.03.05.19 _cn", "scope": null, "trust": 0.6, "vendor": "", "version": null }, { "model": "tenda technology co.,ltd. ac9 ac15 us_ac15v1.0br_v15.03.05.18_multi_td01", "scope": null, "trust": 0.6, "vendor": "", "version": null }, { "model": "tenda technology co.,ltd. ac9 ac15 us_ac15v1.0br_v15.03.05.19_multi_td01", "scope": null, "trust": 0.6, "vendor": "", "version": null }, { "model": "tenda technology co.,ltd. ac9 ac18 us_ac18v1.0br_v15.03.05.05_multi_td01", "scope": null, "trust": 0.6, "vendor": "", "version": null }, { "model": "tenda technology co.,ltd. ac9 ac18 ac18_kf_v15.03.05.19 _cn", "scope": null, "trust": 0.6, "vendor": "", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2017-37811" }, { "db": "JVNDB", "id": "JVNDB-2017-010774" }, { "db": "CNNVD", "id": "CNNVD-201711-888" }, { "db": "NVD", "id": "CVE-2017-16923" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:tenda:ac15_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac18_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tenda:ac9_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2017-010774" } ] }, "cve": "CVE-2017-16923", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 6.5, "id": "CVE-2017-16923", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 6.5, "id": "CNVD-2017-37811", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 6.5, "id": "VHN-107894", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:A/AC:L/AU:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2017-16923", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.8, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2017-16923", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2017-16923", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2017-37811", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201711-888", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-107894", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2017-37811" }, { "db": "VULHUB", "id": "VHN-107894" }, { "db": "JVNDB", "id": "JVNDB-2017-010774" }, { "db": "CNNVD", "id": "CNNVD-201711-888" }, { "db": "NVD", "id": "CVE-2017-16923" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Command Injection vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to execute arbitrary OS commands via a crafted cgi-bin/luci/usbeject?dev_name= GET request from the LAN. This occurs because the \"sub_A6E8 usbeject_process_entry\" function executes a system function with untrusted input. Shenzhen Tenda Ac9 , Ac15 ,and Ac18 The device contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. ShenzhenTendaAc9 and other are the wireless router products of Tenda. App_data_center is one of the application data centers. There is a command injection vulnerability in app_data_center in several ShenzhenTenda products. The following versions are affected: Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01 Version, Ac9 ac9_kf_V15.03.05.19(6318_)_cn Version, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01 Version, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01 Version, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01 version, Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices version", "sources": [ { "db": "NVD", "id": "CVE-2017-16923" }, { "db": "JVNDB", "id": "JVNDB-2017-010774" }, { "db": "CNVD", "id": "CNVD-2017-37811" }, { "db": "VULHUB", "id": "VHN-107894" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2017-16923", "trust": 3.1 }, { "db": "JVNDB", "id": "JVNDB-2017-010774", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201711-888", "trust": 0.7 }, { "db": "CNVD", "id": "CNVD-2017-37811", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-107894", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2017-37811" }, { "db": "VULHUB", "id": "VHN-107894" }, { "db": "JVNDB", "id": "JVNDB-2017-010774" }, { "db": "CNNVD", "id": "CNNVD-201711-888" }, { "db": "NVD", "id": "CVE-2017-16923" } ] }, "id": "VAR-201711-0630", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2017-37811" }, { "db": "VULHUB", "id": "VHN-107894" } ], "trust": 1.1153522033333332 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2017-37811" } ] }, "last_update_date": "2024-11-23T22:45:33.771000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top Page", "trust": 0.8, "url": "http://tendacn.com/en/default.html" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2017-010774" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-78", "trust": 1.1 }, { "problemtype": "CWE-77", "trust": 0.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-107894" }, { "db": "JVNDB", "id": "JVNDB-2017-010774" }, { "db": "NVD", "id": "CVE-2017-16923" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://github.com/iolop/poc/tree/master/router/tenda" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2017-16923" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-16923" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2017-37811" }, { "db": "VULHUB", "id": "VHN-107894" }, { "db": "JVNDB", "id": "JVNDB-2017-010774" }, { "db": "CNNVD", "id": "CNNVD-201711-888" }, { "db": "NVD", "id": "CVE-2017-16923" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2017-37811" }, { "db": "VULHUB", "id": "VHN-107894" }, { "db": "JVNDB", "id": "JVNDB-2017-010774" }, { "db": "CNNVD", "id": "CNNVD-201711-888" }, { "db": "NVD", "id": "CVE-2017-16923" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2017-12-21T00:00:00", "db": "CNVD", "id": "CNVD-2017-37811" }, { "date": "2017-11-21T00:00:00", "db": "VULHUB", "id": "VHN-107894" }, { "date": "2017-12-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2017-010774" }, { "date": "2017-11-24T00:00:00", "db": "CNNVD", "id": "CNNVD-201711-888" }, { "date": "2017-11-21T14:29:00.260000", "db": "NVD", "id": "CVE-2017-16923" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2017-12-21T00:00:00", "db": "CNVD", "id": "CNVD-2017-37811" }, { "date": "2019-10-03T00:00:00", "db": "VULHUB", "id": "VHN-107894" }, { "date": "2017-12-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2017-010774" }, { "date": "2019-10-23T00:00:00", "db": "CNNVD", "id": "CNNVD-201711-888" }, { "date": "2024-11-21T03:17:14.913000", "db": "NVD", "id": "CVE-2017-16923" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-201711-888" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Shenzhen Tenda Command injection vulnerability in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2017-010774" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "operating system commend injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-201711-888" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.