var-201705-3664
Vulnerability from variot
A vulnerability in the web interface of Cisco Remote Expert Manager Software 11.0.0 could allow an unauthenticated, remote attacker to access sensitive Virtual Temporary Directory information on an affected system. The vulnerability exists because the affected software does not sufficiently protect sensitive data when responding to HTTP requests that are sent to the web interface of the software. An attacker could exploit this vulnerability by sending crafted HTTP requests to the web interface of the software on an affected system. A successful exploit could allow the attacker to access sensitive information about the software. The attacker could use this information to conduct additional reconnaissance attacks. Cisco Bug IDs: CSCvc52861. Vendors have confirmed this vulnerability Bug ID CSCvc52861 It is released as.Information may be obtained. The software features collaboration features such as remote screen sharing, screen annotation, and session recording. The vulnerability stems from the program's insufficient protection of sensitive information
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201705-3664", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "remote expert manager", "scope": "eq", "trust": 1.6, "vendor": "cisco", "version": "11.0.0" }, { "model": "remote expert manager software", "scope": "eq", "trust": 0.8, "vendor": "cisco", "version": "11.0.0" }, { "model": "remote expert manager", "scope": "eq", "trust": 0.3, "vendor": "cisco", "version": "11.0" } ], "sources": [ { "db": "BID", "id": "98537" }, { "db": "JVNDB", "id": "JVNDB-2017-004207" }, { "db": "CNNVD", "id": "CNNVD-201705-903" }, { "db": "NVD", "id": "CVE-2017-6645" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/a:cisco:remote_expert_manager", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2017-004207" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Cisco", "sources": [ { "db": "BID", "id": "98537" } ], "trust": 0.3 }, "cve": "CVE-2017-6645", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2017-6645", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "VHN-114848", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 3.9, "id": "CVE-2017-6645", "impactScore": 1.4, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.8, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2017-6645", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "CVE-2017-6645", "trust": 0.8, "value": "Medium" }, { "author": "CNNVD", "id": "CNNVD-201705-903", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULHUB", "id": "VHN-114848", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULHUB", "id": "VHN-114848" }, { "db": "JVNDB", "id": "JVNDB-2017-004207" }, { "db": "CNNVD", "id": "CNNVD-201705-903" }, { "db": "NVD", "id": "CVE-2017-6645" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability in the web interface of Cisco Remote Expert Manager Software 11.0.0 could allow an unauthenticated, remote attacker to access sensitive Virtual Temporary Directory information on an affected system. The vulnerability exists because the affected software does not sufficiently protect sensitive data when responding to HTTP requests that are sent to the web interface of the software. An attacker could exploit this vulnerability by sending crafted HTTP requests to the web interface of the software on an affected system. A successful exploit could allow the attacker to access sensitive information about the software. The attacker could use this information to conduct additional reconnaissance attacks. Cisco Bug IDs: CSCvc52861. Vendors have confirmed this vulnerability Bug ID CSCvc52861 It is released as.Information may be obtained. The software features collaboration features such as remote screen sharing, screen annotation, and session recording. The vulnerability stems from the program\u0027s insufficient protection of sensitive information", "sources": [ { "db": "NVD", "id": "CVE-2017-6645" }, { "db": "JVNDB", "id": "JVNDB-2017-004207" }, { "db": "BID", "id": "98537" }, { "db": "VULHUB", "id": "VHN-114848" } ], "trust": 1.98 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2017-6645", "trust": 2.8 }, { "db": "BID", "id": "98537", "trust": 2.0 }, { "db": "JVNDB", "id": "JVNDB-2017-004207", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201705-903", "trust": 0.7 }, { "db": "VULHUB", "id": "VHN-114848", "trust": 0.1 } ], "sources": [ { "db": "VULHUB", "id": "VHN-114848" }, { "db": "BID", "id": "98537" }, { "db": "JVNDB", "id": "JVNDB-2017-004207" }, { "db": "CNNVD", "id": "CNNVD-201705-903" }, { "db": "NVD", "id": "CVE-2017-6645" } ] }, "id": "VAR-201705-3664", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-114848" } ], "trust": 0.01 }, "last_update_date": "2024-11-23T23:12:27.073000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "cisco-sa-20170517-rem5", "trust": 0.8, "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170517-rem5" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2017-004207" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-200", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-114848" }, { "db": "JVNDB", "id": "JVNDB-2017-004207" }, { "db": "NVD", "id": "CVE-2017-6645" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-20170517-rem5" }, { "trust": 1.7, "url": "http://www.securityfocus.com/bid/98537" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-6645" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2017-6645" }, { "trust": 0.3, "url": "http://www.cisco.com/" } ], "sources": [ { "db": "VULHUB", "id": "VHN-114848" }, { "db": "BID", "id": "98537" }, { "db": "JVNDB", "id": "JVNDB-2017-004207" }, { "db": "CNNVD", "id": "CNNVD-201705-903" }, { "db": "NVD", "id": "CVE-2017-6645" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULHUB", "id": "VHN-114848" }, { "db": "BID", "id": "98537" }, { "db": "JVNDB", "id": "JVNDB-2017-004207" }, { "db": "CNNVD", "id": "CNNVD-201705-903" }, { "db": "NVD", "id": "CVE-2017-6645" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2017-05-22T00:00:00", "db": "VULHUB", "id": "VHN-114848" }, { "date": "2017-05-17T00:00:00", "db": "BID", "id": "98537" }, { "date": "2017-06-20T00:00:00", "db": "JVNDB", "id": "JVNDB-2017-004207" }, { "date": "2017-05-22T00:00:00", "db": "CNNVD", "id": "CNNVD-201705-903" }, { "date": "2017-05-22T01:29:00.650000", "db": "NVD", "id": "CVE-2017-6645" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-10-09T00:00:00", "db": "VULHUB", "id": "VHN-114848" }, { "date": "2017-05-17T00:00:00", "db": "BID", "id": "98537" }, { "date": "2017-06-20T00:00:00", "db": "JVNDB", "id": "JVNDB-2017-004207" }, { "date": "2019-10-17T00:00:00", "db": "CNNVD", "id": "CNNVD-201705-903" }, { "date": "2024-11-21T03:30:12.543000", "db": "NVD", "id": "CVE-2017-6645" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201705-903" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Cisco Remote Expert Manager Information disclosure vulnerability in software", "sources": [ { "db": "JVNDB", "id": "JVNDB-2017-004207" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "information disclosure", "sources": [ { "db": "CNNVD", "id": "CNNVD-201705-903" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.