var-201704-0745
Vulnerability from variot

A buffer overflow vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pack 1 may allow an authenticated malicious user to cause a buffer overflow leading to a denial of service. JuniperNetworksNorthStarControllerApplication is a traffic planning controller from Juniper Networks. The controller optimizes the service provider's transport network by establishing an open industry standard protocol. An attacker could exploit the vulnerability to cause a denial of service. Successful exploits may allow an attacker to execute arbitrary code or cause denial-of-service conditions

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201704-0745",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "northstar controller",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "juniper",
        "version": "2.1.0"
      },
      {
        "model": "northstar controller",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "juniper",
        "version": "2.1.0 service pack 1"
      },
      {
        "model": "networks northstar controller application service pack",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "juniper",
        "version": "2.1.01"
      },
      {
        "model": "northstar controller",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "juniper",
        "version": "2.1.0"
      },
      {
        "model": "northstar controller application",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "juniper",
        "version": "2.1.0"
      },
      {
        "model": "northstar controller application service pack",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "juniper",
        "version": "2.1.01"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-07222"
      },
      {
        "db": "BID",
        "id": "97602"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-003349"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201704-995"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2325"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:juniper:northstar_controller",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-003349"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "The vendor reported this issue.",
    "sources": [
      {
        "db": "BID",
        "id": "97602"
      }
    ],
    "trust": 0.3
  },
  "cve": "CVE-2017-2325",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 4.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.0,
            "id": "CVE-2017-2325",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 4.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2017-07222",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 4.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.0,
            "id": "VHN-110528",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:S/C:N/I:N/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.8,
            "id": "CVE-2017-2325",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2017-2325",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2017-2325",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2017-07222",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201704-995",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-110528",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-07222"
      },
      {
        "db": "VULHUB",
        "id": "VHN-110528"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-003349"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201704-995"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2325"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A buffer overflow vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pack 1 may allow an authenticated malicious user to cause a buffer overflow leading to a denial of service. JuniperNetworksNorthStarControllerApplication is a traffic planning controller from Juniper Networks. The controller optimizes the service provider\u0027s transport network by establishing an open industry standard protocol. An attacker could exploit the vulnerability to cause a denial of service. \nSuccessful exploits may allow an attacker to execute arbitrary code or cause denial-of-service conditions",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-2325"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-003349"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-07222"
      },
      {
        "db": "BID",
        "id": "97602"
      },
      {
        "db": "VULHUB",
        "id": "VHN-110528"
      }
    ],
    "trust": 2.52
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2017-2325",
        "trust": 3.4
      },
      {
        "db": "BID",
        "id": "97602",
        "trust": 2.6
      },
      {
        "db": "JUNIPER",
        "id": "JSA10783",
        "trust": 2.6
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-003349",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201704-995",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-07222",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-110528",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-07222"
      },
      {
        "db": "VULHUB",
        "id": "VHN-110528"
      },
      {
        "db": "BID",
        "id": "97602"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-003349"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201704-995"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2325"
      }
    ]
  },
  "id": "VAR-201704-0745",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-07222"
      },
      {
        "db": "VULHUB",
        "id": "VHN-110528"
      }
    ],
    "trust": 1.29105265
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-07222"
      }
    ]
  },
  "last_update_date": "2024-11-23T20:22:32.077000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "JSA10783",
        "trust": 0.8,
        "url": "https://kb.juniper.net/JSA10783"
      },
      {
        "title": "Patch for JuniperNetworksNorthStarControllerApplication Buffer Overflow Vulnerability (CNVD-2017-07222)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/94107"
      },
      {
        "title": "Juniper Networks NorthStar Controller Application Buffer error vulnerability fix",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=70259"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-07222"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-003349"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201704-995"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-110528"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-003349"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2325"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.3,
        "url": "http://www.securityfocus.com/bid/97602"
      },
      {
        "trust": 2.3,
        "url": "https://kb.juniper.net/jsa10783"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-2325"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-2325"
      },
      {
        "trust": 0.3,
        "url": "https://www.juniper.net/us/en/products-services/sdn/northstar-network-controller/"
      },
      {
        "trust": 0.3,
        "url": "https://kb.juniper.net/infocenter/index?page=content\u0026id=jsa10783\u0026cat=sirt_1\u0026actp=list"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-07222"
      },
      {
        "db": "VULHUB",
        "id": "VHN-110528"
      },
      {
        "db": "BID",
        "id": "97602"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-003349"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201704-995"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2325"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-07222"
      },
      {
        "db": "VULHUB",
        "id": "VHN-110528"
      },
      {
        "db": "BID",
        "id": "97602"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-003349"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201704-995"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2325"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-05-22T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-07222"
      },
      {
        "date": "2017-04-24T00:00:00",
        "db": "VULHUB",
        "id": "VHN-110528"
      },
      {
        "date": "2017-04-12T00:00:00",
        "db": "BID",
        "id": "97602"
      },
      {
        "date": "2017-05-25T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-003349"
      },
      {
        "date": "2017-04-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201704-995"
      },
      {
        "date": "2017-04-24T15:59:00.567000",
        "db": "NVD",
        "id": "CVE-2017-2325"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-05-23T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-07222"
      },
      {
        "date": "2017-04-27T00:00:00",
        "db": "VULHUB",
        "id": "VHN-110528"
      },
      {
        "date": "2017-04-18T01:04:00",
        "db": "BID",
        "id": "97602"
      },
      {
        "date": "2017-05-25T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-003349"
      },
      {
        "date": "2017-05-17T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201704-995"
      },
      {
        "date": "2024-11-21T03:23:17.293000",
        "db": "NVD",
        "id": "CVE-2017-2325"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201704-995"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Juniper Networks NorthStar Controller Application buffer overflow vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-003349"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer overflow",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201704-995"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…