var-201703-0644
Vulnerability from variot

Siemens RUGGEDCOM ROX I (all versions) contain a vulnerability in the integrated web server at port 10000/TCP which is prone to reflected Cross-Site Scripting attacks if an unsuspecting user is induced to click on a malicious link. SiemensRuggedCom's ROX-based firewall devices are used to connect devices in harsh environments such as substations, traffic management chassis, and more. Siemens RUGGEDCOM ROX I is prone to the following security vulnerabilities: : 1. A HTML-injection vulnerability 2. An information-disclosure vulnerability 4. An authorization-bypass vulnerability 5. A cross-site request-forgery vulnerability An attacker may leverage these issues to execute HTML and script code in the browser of an unsuspecting user in the context of the affected site, disclose sensitive information, perform certain unauthorized actions actions, gain unauthorized access, or bypass certain security restrictions

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201703-0644",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ruggedcom rox i",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.9.0"
      },
      {
        "model": "ruggedcom rox i",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "ruggedcom rox i",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "ruggedcom rox i",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "2.9.0"
      },
      {
        "model": "ruggedcom rox i",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "ruggedcom rox i",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "2f332dd1-8155-4d9b-81db-31bf76d9ed5e"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-03651"
      },
      {
        "db": "BID",
        "id": "97170"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-002721"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201703-1334"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2687"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:siemens:ruggedcom_rox_i",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-002721"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Maxim Rupp",
    "sources": [
      {
        "db": "BID",
        "id": "97170"
      }
    ],
    "trust": 0.3
  },
  "cve": "CVE-2017-2687",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.6,
            "id": "CVE-2017-2687",
            "impactScore": 2.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 6.4,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2017-03651",
            "impactScore": 4.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "NONE",
            "baseScore": 6.4,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "2f332dd1-8155-4d9b-81db-31bf76d9ed5e",
            "impactScore": 4.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N",
            "version": "2.9 [IVD]"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 2.8,
            "id": "CVE-2017-2687",
            "impactScore": 2.7,
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "trust": 1.8,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2017-2687",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2017-2687",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2017-03651",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201703-1334",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "IVD",
            "id": "2f332dd1-8155-4d9b-81db-31bf76d9ed5e",
            "trust": 0.2,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "2f332dd1-8155-4d9b-81db-31bf76d9ed5e"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-03651"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-002721"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201703-1334"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2687"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens RUGGEDCOM ROX I (all versions) contain a vulnerability in the integrated web server at port 10000/TCP which is prone to reflected Cross-Site Scripting attacks if an unsuspecting user is induced to click on a malicious link. SiemensRuggedCom\u0027s ROX-based firewall devices are used to connect devices in harsh environments such as substations, traffic management chassis, and more. Siemens RUGGEDCOM ROX I is prone to the following security vulnerabilities: :\n1. A HTML-injection vulnerability\n2. An information-disclosure vulnerability\n4. An authorization-bypass vulnerability\n5. A cross-site request-forgery vulnerability\nAn attacker may leverage these issues to execute HTML and script code in the browser of an unsuspecting user in the context of the affected site, disclose sensitive information, perform certain unauthorized actions actions, gain unauthorized access, or bypass certain security restrictions",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-2687"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-002721"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-03651"
      },
      {
        "db": "BID",
        "id": "97170"
      },
      {
        "db": "IVD",
        "id": "2f332dd1-8155-4d9b-81db-31bf76d9ed5e"
      }
    ],
    "trust": 2.61
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2017-2687",
        "trust": 3.5
      },
      {
        "db": "SIEMENS",
        "id": "SSA-327980",
        "trust": 2.5
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-17-087-01",
        "trust": 1.3
      },
      {
        "db": "BID",
        "id": "97170",
        "trust": 1.3
      },
      {
        "db": "SECTRACK",
        "id": "1038160",
        "trust": 1.0
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-03651",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201703-1334",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-002721",
        "trust": 0.8
      },
      {
        "db": "IVD",
        "id": "2F332DD1-8155-4D9B-81DB-31BF76D9ED5E",
        "trust": 0.2
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "2f332dd1-8155-4d9b-81db-31bf76d9ed5e"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-03651"
      },
      {
        "db": "BID",
        "id": "97170"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-002721"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201703-1334"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2687"
      }
    ]
  },
  "id": "VAR-201703-0644",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "2f332dd1-8155-4d9b-81db-31bf76d9ed5e"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-03651"
      }
    ],
    "trust": 1.32540106
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS",
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      },
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.2
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "2f332dd1-8155-4d9b-81db-31bf76d9ed5e"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-03651"
      }
    ]
  },
  "last_update_date": "2024-11-23T21:41:38.278000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-327980",
        "trust": 0.8,
        "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-327980.pdf"
      },
      {
        "title": "Patch for SiemensRUGGEDCOMROXI Cross-Site Scripting Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/91178"
      },
      {
        "title": "Siemens RUGGEDCOM ROX I Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=68862"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-03651"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-002721"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201703-1334"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-79",
        "trust": 1.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-002721"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2687"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-327980.pdf"
      },
      {
        "trust": 1.3,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-17-087-01"
      },
      {
        "trust": 1.0,
        "url": "http://www.securityfocus.com/bid/97170"
      },
      {
        "trust": 1.0,
        "url": "http://www.securitytracker.com/id/1038160"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-2687"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-2687"
      },
      {
        "trust": 0.3,
        "url": "http://subscriber.communications.siemens.com/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-03651"
      },
      {
        "db": "BID",
        "id": "97170"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-002721"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201703-1334"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2687"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "2f332dd1-8155-4d9b-81db-31bf76d9ed5e"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-03651"
      },
      {
        "db": "BID",
        "id": "97170"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-002721"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201703-1334"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2687"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-03-29T00:00:00",
        "db": "IVD",
        "id": "2f332dd1-8155-4d9b-81db-31bf76d9ed5e"
      },
      {
        "date": "2017-03-29T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-03651"
      },
      {
        "date": "2017-03-28T00:00:00",
        "db": "BID",
        "id": "97170"
      },
      {
        "date": "2017-04-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-002721"
      },
      {
        "date": "2017-03-30T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201703-1334"
      },
      {
        "date": "2017-03-29T01:59:01.737000",
        "db": "NVD",
        "id": "CVE-2017-2687"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-03-29T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-03651"
      },
      {
        "date": "2017-03-28T00:00:00",
        "db": "BID",
        "id": "97170"
      },
      {
        "date": "2017-04-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-002721"
      },
      {
        "date": "2017-03-30T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201703-1334"
      },
      {
        "date": "2024-11-21T03:23:58.803000",
        "db": "NVD",
        "id": "CVE-2017-2687"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201703-1334"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens RUGGEDCOM ROX I Cross-Site Scripting Vulnerability",
    "sources": [
      {
        "db": "IVD",
        "id": "2f332dd1-8155-4d9b-81db-31bf76d9ed5e"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-03651"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "XSS",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201703-1334"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…