var-201702-0428
Vulnerability from variot
An issue was discovered in Schneider Electric PowerLogic PM8ECC device 2.651 and older. Undocumented hard-coded credentials allow access to the device.
Schneider Electric PowerLogic PM8ECC for PowerMeter 800 versions prior to 2.651 have a security bypass vulnerability that could be exploited by an attacker to bypass security restrictions and perform unauthorized operations. Attackers can exploit this issue to bypass the authentication mechanism and gain access to the vulnerable device
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201702-0428", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "powerlogic pm8ecc", "scope": "eq", "trust": 1.9, "vendor": "schneider electric", "version": "2.651" }, { "model": "powerlogic pm8ecc", "scope": null, "trust": 0.8, "vendor": "schneider electric", "version": null }, { "model": "powerlogic pm8ecc", "scope": "lte", "trust": 0.8, "vendor": "schneider electric", "version": "2.651" }, { "model": "electric powerlogic pm8ecc", "scope": "lte", "trust": 0.6, "vendor": "schneider", "version": "\u003c=2.651" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2016-10041" }, { "db": "BID", "id": "93602" }, { "db": "JVNDB", "id": "JVNDB-2016-007629" }, { "db": "CNNVD", "id": "CNNVD-201610-478" }, { "db": "NVD", "id": "CVE-2016-5818" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/h:schneider_electric:powerlogic_pm8ecc", "vulnerable": true }, { "cpe22Uri": "cpe:/o:schneider_electric:powerlogic_pm8ecc_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2016-007629" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "He Congwen.", "sources": [ { "db": "BID", "id": "93602" }, { "db": "CNNVD", "id": "CNNVD-201610-478" } ], "trust": 0.9 }, "cve": "CVE-2016-5818", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2016-5818", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "CNVD-2016-10041", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "VHN-94637", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2016-5818", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.8, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2016-5818", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2016-5818", "trust": 0.8, "value": "Critical" }, { "author": "CNVD", "id": "CNVD-2016-10041", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-201610-478", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-94637", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2016-10041" }, { "db": "VULHUB", "id": "VHN-94637" }, { "db": "JVNDB", "id": "JVNDB-2016-007629" }, { "db": "CNNVD", "id": "CNNVD-201610-478" }, { "db": "NVD", "id": "CVE-2016-5818" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "An issue was discovered in Schneider Electric PowerLogic PM8ECC device 2.651 and older. Undocumented hard-coded credentials allow access to the device. \n\nSchneider Electric PowerLogic PM8ECC for PowerMeter 800 versions prior to 2.651 have a security bypass vulnerability that could be exploited by an attacker to bypass security restrictions and perform unauthorized operations. \nAttackers can exploit this issue to bypass the authentication mechanism and gain access to the vulnerable device", "sources": [ { "db": "NVD", "id": "CVE-2016-5818" }, { "db": "JVNDB", "id": "JVNDB-2016-007629" }, { "db": "CNVD", "id": "CNVD-2016-10041" }, { "db": "BID", "id": "93602" }, { "db": "VULHUB", "id": "VHN-94637" } ], "trust": 2.52 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2016-5818", "trust": 3.4 }, { "db": "ICS CERT", "id": "ICSA-16-292-01", "trust": 2.8 }, { "db": "BID", "id": "93602", "trust": 2.6 }, { "db": "JVNDB", "id": "JVNDB-2016-007629", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201610-478", "trust": 0.7 }, { "db": "CNVD", "id": "CNVD-2016-10041", "trust": 0.6 }, { "db": "SEEBUG", "id": "SSVID-91958", "trust": 0.1 }, { "db": "VULHUB", "id": "VHN-94637", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2016-10041" }, { "db": "VULHUB", "id": "VHN-94637" }, { "db": "BID", "id": "93602" }, { "db": "JVNDB", "id": "JVNDB-2016-007629" }, { "db": "CNNVD", "id": "CNNVD-201610-478" }, { "db": "NVD", "id": "CVE-2016-5818" } ] }, "id": "VAR-201702-0428", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2016-10041" }, { "db": "VULHUB", "id": "VHN-94637" } ], "trust": 1.7 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2016-10041" } ] }, "last_update_date": "2024-11-23T22:30:51.308000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "PM8ECC", "trust": 0.8, "url": "http://www.schneider-electric.com/en/product/PM8ECC/ethernet-communication-module---10-100basetx-utp-port" }, { "title": "Patch for Schneider Electric PowerLogic PM8ECC Security Bypass Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/83039" }, { "title": "Schneider Electric PowerLogic PM8ECC Repair measures for security bypass vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=64847" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2016-10041" }, { "db": "JVNDB", "id": "JVNDB-2016-007629" }, { "db": "CNNVD", "id": "CNNVD-201610-478" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-798", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-94637" }, { "db": "JVNDB", "id": "JVNDB-2016-007629" }, { "db": "NVD", "id": "CVE-2016-5818" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.8, "url": "https://ics-cert.us-cert.gov/advisories/icsa-16-292-01" }, { "trust": 2.3, "url": "http://www.securityfocus.com/bid/93602" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2016-5818" }, { "trust": 0.8, "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2016-5818" }, { "trust": 0.3, "url": "http://www.schneider-electric.com/site/home/index.cfm/ww/?selectcountry=true" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2016-10041" }, { "db": "VULHUB", "id": "VHN-94637" }, { "db": "BID", "id": "93602" }, { "db": "JVNDB", "id": "JVNDB-2016-007629" }, { "db": "CNNVD", "id": "CNNVD-201610-478" }, { "db": "NVD", "id": "CVE-2016-5818" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2016-10041" }, { "db": "VULHUB", "id": "VHN-94637" }, { "db": "BID", "id": "93602" }, { "db": "JVNDB", "id": "JVNDB-2016-007629" }, { "db": "CNNVD", "id": "CNNVD-201610-478" }, { "db": "NVD", "id": "CVE-2016-5818" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2016-10-26T00:00:00", "db": "CNVD", "id": "CNVD-2016-10041" }, { "date": "2017-02-13T00:00:00", "db": "VULHUB", "id": "VHN-94637" }, { "date": "2016-10-18T00:00:00", "db": "BID", "id": "93602" }, { "date": "2017-03-08T00:00:00", "db": "JVNDB", "id": "JVNDB-2016-007629" }, { "date": "2016-10-19T00:00:00", "db": "CNNVD", "id": "CNNVD-201610-478" }, { "date": "2017-02-13T21:59:00.533000", "db": "NVD", "id": "CVE-2016-5818" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2016-10-26T00:00:00", "db": "CNVD", "id": "CNVD-2016-10041" }, { "date": "2017-02-17T00:00:00", "db": "VULHUB", "id": "VHN-94637" }, { "date": "2016-10-26T02:08:00", "db": "BID", "id": "93602" }, { "date": "2017-03-08T00:00:00", "db": "JVNDB", "id": "JVNDB-2016-007629" }, { "date": "2016-10-19T00:00:00", "db": "CNNVD", "id": "CNNVD-201610-478" }, { "date": "2024-11-21T02:55:04.053000", "db": "NVD", "id": "CVE-2016-5818" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201610-478" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Schneider Electric PowerLogic PM8ECC Security Bypass Vulnerability", "sources": [ { "db": "CNVD", "id": "CNVD-2016-10041" }, { "db": "CNNVD", "id": "CNNVD-201610-478" } ], "trust": 1.2 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-201610-478" } ], "trust": 0.6 } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…