var-201512-0070
Vulnerability from variot

Eaton Cooper Power Systems ProView 4.x and 5.x before 5.1 on Form 6 controls and Idea and IdeaPLUS relays does not properly initialize padding fields in Ethernet packets, which allows remote attackers to obtain sensitive information by reading packet data. Eaton Form 6 control and Idea/IdeaPLUS are products of Eaton Corporation of the United States. The former is a controller product that provides instant access operations and quickly determines device status and locates device failures. The latter is a relay protection platform. An attacker could exploit the vulnerability to disclose information. Multiple Eaton Cooper Power Systems products are prone to an information-disclosure vulnerability

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201512-0070",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "proview",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "eaton",
        "version": "5.0.2"
      },
      {
        "model": "proview",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "eaton",
        "version": "5.0.9"
      },
      {
        "model": "proview",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "eaton",
        "version": "5.0.5"
      },
      {
        "model": "proview",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "eaton",
        "version": "5.0.6"
      },
      {
        "model": "proview",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "eaton",
        "version": "5.0.1"
      },
      {
        "model": "proview",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "eaton",
        "version": "5.0.3"
      },
      {
        "model": "proview",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "eaton",
        "version": "4.0"
      },
      {
        "model": "proview",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "eaton",
        "version": "5.0.10"
      },
      {
        "model": "proview",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "eaton",
        "version": "5.0"
      },
      {
        "model": "proview",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "eaton",
        "version": "5.0.4"
      },
      {
        "model": "proview",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "eaton",
        "version": "5.0.8"
      },
      {
        "model": "proview",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "eaton",
        "version": "5.0.7"
      },
      {
        "model": "proview",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "eaton",
        "version": "5.1"
      },
      {
        "model": "proview",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "eaton",
        "version": "4.x"
      },
      {
        "model": "proview",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "eaton",
        "version": "5.x"
      },
      {
        "model": "form control",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "eaton",
        "version": "6"
      },
      {
        "model": "dea/ideaplus",
        "scope": null,
        "trust": 0.6,
        "vendor": "eaton",
        "version": null
      },
      {
        "model": "cooper power systems form recloser control pro view",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "eaton",
        "version": "65.0"
      },
      {
        "model": "cooper power systems form recloser control pro view",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "eaton",
        "version": "64.0"
      },
      {
        "model": "cooper power systems edison idea relays pro view",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "eaton",
        "version": "5.0"
      },
      {
        "model": "cooper power systems edison idea relays pro view",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "eaton",
        "version": "4.0"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "proview",
        "version": "4.0"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "proview",
        "version": "5.0"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "proview",
        "version": "5.0.1"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "proview",
        "version": "5.0.2"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "proview",
        "version": "5.0.3"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "proview",
        "version": "5.0.4"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "proview",
        "version": "5.0.5"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "proview",
        "version": "5.0.6"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "proview",
        "version": "5.0.7"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "proview",
        "version": "5.0.8"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "proview",
        "version": "5.0.9"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "proview",
        "version": "5.0.10"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "1899dbe4-82f8-4e24-a1ab-d648877eec3f"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-07811"
      },
      {
        "db": "BID",
        "id": "77819"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-006511"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201511-420"
      },
      {
        "db": "NVD",
        "id": "CVE-2015-6471"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:eaton:proview",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-006511"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "David Formby and Raheem Beyah of Georgia Tech",
    "sources": [
      {
        "db": "BID",
        "id": "77819"
      }
    ],
    "trust": 0.3
  },
  "cve": "CVE-2015-6471",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CVE-2015-6471",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.9,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 4.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2015-07811",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "IVD",
            "availabilityImpact": "NONE",
            "baseScore": 4.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "id": "1899dbe4-82f8-4e24-a1ab-d648877eec3f",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
            "version": "2.9 [IVD]"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 3.9,
            "id": "CVE-2015-6471",
            "impactScore": 1.4,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2015-6471",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2015-6471",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2015-07811",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201511-420",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "IVD",
            "id": "1899dbe4-82f8-4e24-a1ab-d648877eec3f",
            "trust": 0.2,
            "value": "MEDIUM"
          },
          {
            "author": "VULMON",
            "id": "CVE-2015-6471",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "1899dbe4-82f8-4e24-a1ab-d648877eec3f"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-07811"
      },
      {
        "db": "VULMON",
        "id": "CVE-2015-6471"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-006511"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201511-420"
      },
      {
        "db": "NVD",
        "id": "CVE-2015-6471"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Eaton Cooper Power Systems ProView 4.x and 5.x before 5.1 on Form 6 controls and Idea and IdeaPLUS relays does not properly initialize padding fields in Ethernet packets, which allows remote attackers to obtain sensitive information by reading packet data. Eaton Form 6 control and Idea/IdeaPLUS are products of Eaton Corporation of the United States. The former is a controller product that provides instant access operations and quickly determines device status and locates device failures. The latter is a relay protection platform. An attacker could exploit the vulnerability to disclose information. Multiple Eaton Cooper Power Systems products are prone to an information-disclosure vulnerability",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2015-6471"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-006511"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-07811"
      },
      {
        "db": "BID",
        "id": "77819"
      },
      {
        "db": "IVD",
        "id": "1899dbe4-82f8-4e24-a1ab-d648877eec3f"
      },
      {
        "db": "VULMON",
        "id": "CVE-2015-6471"
      }
    ],
    "trust": 2.7
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2015-6471",
        "trust": 3.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-15-295-01",
        "trust": 3.4
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-07811",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201511-420",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-006511",
        "trust": 0.8
      },
      {
        "db": "BID",
        "id": "77819",
        "trust": 0.4
      },
      {
        "db": "IVD",
        "id": "1899DBE4-82F8-4E24-A1AB-D648877EEC3F",
        "trust": 0.2
      },
      {
        "db": "VULMON",
        "id": "CVE-2015-6471",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "1899dbe4-82f8-4e24-a1ab-d648877eec3f"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-07811"
      },
      {
        "db": "VULMON",
        "id": "CVE-2015-6471"
      },
      {
        "db": "BID",
        "id": "77819"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-006511"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201511-420"
      },
      {
        "db": "NVD",
        "id": "CVE-2015-6471"
      }
    ]
  },
  "id": "VAR-201512-0070",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "1899dbe4-82f8-4e24-a1ab-d648877eec3f"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-07811"
      }
    ],
    "trust": 1.8
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "1899dbe4-82f8-4e24-a1ab-d648877eec3f"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-07811"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:22:48.651000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "ProView Software Download",
        "trust": 0.8,
        "url": "http://www.cooperindustries.com/content/public/en/power_systems/products/controls_and_relays/recloser_controls/proview-software-for-form-6-control.html"
      },
      {
        "title": "Patch for Eaton Form 6 control and Idea/IdeaPLUS Information Disclosure Vulnerabilities",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/67229"
      },
      {
        "title": "Eaton Form 6 control  and Idea/IdeaPLUS Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=58855"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2015-07811"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-006511"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201511-420"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-200",
        "trust": 1.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-006511"
      },
      {
        "db": "NVD",
        "id": "CVE-2015-6471"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.5,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-15-295-01"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2015-6471"
      },
      {
        "trust": 0.8,
        "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2015-6471"
      },
      {
        "trust": 0.3,
        "url": "http://www.ibm.com"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/200.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://www.securityfocus.com/bid/77819"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2015-07811"
      },
      {
        "db": "VULMON",
        "id": "CVE-2015-6471"
      },
      {
        "db": "BID",
        "id": "77819"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-006511"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201511-420"
      },
      {
        "db": "NVD",
        "id": "CVE-2015-6471"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "1899dbe4-82f8-4e24-a1ab-d648877eec3f"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-07811"
      },
      {
        "db": "VULMON",
        "id": "CVE-2015-6471"
      },
      {
        "db": "BID",
        "id": "77819"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-006511"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201511-420"
      },
      {
        "db": "NVD",
        "id": "CVE-2015-6471"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2015-11-27T00:00:00",
        "db": "IVD",
        "id": "1899dbe4-82f8-4e24-a1ab-d648877eec3f"
      },
      {
        "date": "2015-11-27T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2015-07811"
      },
      {
        "date": "2015-12-23T00:00:00",
        "db": "VULMON",
        "id": "CVE-2015-6471"
      },
      {
        "date": "2015-11-24T00:00:00",
        "db": "BID",
        "id": "77819"
      },
      {
        "date": "2015-12-24T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2015-006511"
      },
      {
        "date": "2015-11-25T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201511-420"
      },
      {
        "date": "2015-12-23T03:59:01.170000",
        "db": "NVD",
        "id": "CVE-2015-6471"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2015-11-27T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2015-07811"
      },
      {
        "date": "2015-12-23T00:00:00",
        "db": "VULMON",
        "id": "CVE-2015-6471"
      },
      {
        "date": "2015-11-24T00:00:00",
        "db": "BID",
        "id": "77819"
      },
      {
        "date": "2015-12-24T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2015-006511"
      },
      {
        "date": "2015-12-24T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201511-420"
      },
      {
        "date": "2024-11-21T02:35:02.023000",
        "db": "NVD",
        "id": "CVE-2015-6471"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201511-420"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Eaton Cooper Power System Form 6 Control and  Idea/IdeaPLUS Relays Run on  ProView Vulnerability where important information is obtained",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-006511"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "information disclosure",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201511-420"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…