var-201507-0039
Vulnerability from variot
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02. Specially crafted packets sent to port 50000/UDP could cause a denial-of-service of the affected device. A manual reboot may be required to recover the service of the device. Siemens SIPROTEC 4 and SIPROTEC Compact Device EN100 Module firmware has a service disruption (DoS) There are vulnerabilities that are put into a state. Supplementary information : CWE Vulnerability type by CWE-19: Data Handling ( Data processing ) Has been identified. http://cwe.mitre.org/data/definitions/19.htmlBy a third party UDP port 50000 Denial of service via the above crafted packets (DoS) There is a possibility of being put into a state. The SIPROTEC 4 and SIPROTEC devices offer a wide range of integrated protection, control, measurement and power substation automation functions; the EN100 module is used for IEC 61850 communication. The EN100 module for multiple Siemens SIPROTEC products are prone to a denial-of-service vulnerability. Remote attackers may exploit this issue to cause denial-of-service conditions, denying service to legitimate users. Both Siemens SIPROTEC 4 and SIPROTEC Compact are products of Siemens, Germany. Siemens SIPROTEC 4 is a series of multifunctional relays with a friendly man-machine interface. SIPROTEC Compact is a microcomputer protection device. EN100 is one of the multi-format encoder modules
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201507-0039", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "siprotec", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "4.24" }, { "model": "siprotec 4", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "siprotec compact", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "siprotec", "scope": "lt", "trust": 0.8, "vendor": "siemens", "version": "4.25" }, { "model": "siprotec", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v4.24" }, { "model": null, "scope": "eq", "trust": 0.4, "vendor": "siprotec", "version": "4.24" }, { "model": "siprotec compact", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "siprotec 7ut686", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "siprotec 7sj686", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "siprotec 7sj66", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "siprotec 7sd686", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "siprotec", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "40" }, { "model": "profinet io", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "modbus tcp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "iec", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "1040" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.9" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.6" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.5" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.4" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.3" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.24" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.23" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.22" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.21" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.20" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.2" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.19" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.18" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.17" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.16" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.15" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.14" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.13" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.12" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.11" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.10" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.1" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.0" }, { "model": "dnp3 tcp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "profinet io", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "1.4.1" }, { "model": "en100", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.25" } ], "sources": [ { "db": "IVD", "id": "78fdecc2-a9af-4a66-b218-01a620b751d5" }, { "db": "IVD", "id": "820a6b4c-2351-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2015-04733" }, { "db": "BID", "id": "75948" }, { "db": "JVNDB", "id": "JVNDB-2015-003890" }, { "db": "CNNVD", "id": "CNNVD-201507-644" }, { "db": "NVD", "id": "CVE-2015-5374" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/h:siemens:siprotec_4", "vulnerable": true }, { "cpe22Uri": "cpe:/h:siemens:siprotec_compact", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:siprotec_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2015-003890" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "M. Can Kurnaz", "sources": [ { "db": "CNNVD", "id": "CNNVD-201507-644" } ], "trust": 0.6 }, "cve": "CVE-2015-5374", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2015-5374", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2015-04733", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "78fdecc2-a9af-4a66-b218-01a620b751d5", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "820a6b4c-2351-11e6-abef-000c29c66e3d", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "VHN-83335", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2015-5374", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2015-5374", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2015-04733", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201507-644", "trust": 0.6, "value": "HIGH" }, { "author": "IVD", "id": "78fdecc2-a9af-4a66-b218-01a620b751d5", "trust": 0.2, "value": "HIGH" }, { "author": "IVD", "id": "820a6b4c-2351-11e6-abef-000c29c66e3d", "trust": 0.2, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-83335", "trust": 0.1, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2015-5374", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "IVD", "id": "78fdecc2-a9af-4a66-b218-01a620b751d5" }, { "db": "IVD", "id": "820a6b4c-2351-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2015-04733" }, { "db": "VULHUB", "id": "VHN-83335" }, { "db": "VULMON", "id": "CVE-2015-5374" }, { "db": "JVNDB", "id": "JVNDB-2015-003890" }, { "db": "CNNVD", "id": "CNNVD-201507-644" }, { "db": "NVD", "id": "CVE-2015-5374" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. Specially crafted packets sent to port 50000/UDP could cause a denial-of-service of the affected device. A manual reboot may be required to recover the service of the device. Siemens SIPROTEC 4 and SIPROTEC Compact Device EN100 Module firmware has a service disruption (DoS) There are vulnerabilities that are put into a state. Supplementary information : CWE Vulnerability type by CWE-19: Data Handling ( Data processing ) Has been identified. http://cwe.mitre.org/data/definitions/19.htmlBy a third party UDP port 50000 Denial of service via the above crafted packets (DoS) There is a possibility of being put into a state. The SIPROTEC 4 and SIPROTEC devices offer a wide range of integrated protection, control, measurement and power substation automation functions; the EN100 module is used for IEC 61850 communication. The EN100 module for multiple Siemens SIPROTEC products are prone to a denial-of-service vulnerability. \nRemote attackers may exploit this issue to cause denial-of-service conditions, denying service to legitimate users. Both Siemens SIPROTEC 4 and SIPROTEC Compact are products of Siemens, Germany. Siemens SIPROTEC 4 is a series of multifunctional relays with a friendly man-machine interface. SIPROTEC Compact is a microcomputer protection device. EN100 is one of the multi-format encoder modules", "sources": [ { "db": "NVD", "id": "CVE-2015-5374" }, { "db": "JVNDB", "id": "JVNDB-2015-003890" }, { "db": "CNVD", "id": "CNVD-2015-04733" }, { "db": "BID", "id": "75948" }, { "db": "IVD", "id": "78fdecc2-a9af-4a66-b218-01a620b751d5" }, { "db": "IVD", "id": "820a6b4c-2351-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-83335" }, { "db": "VULMON", "id": "CVE-2015-5374" } ], "trust": 2.97 }, "exploit_availability": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/exploit_availability#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "reference": "https://www.scap.org.cn/vuln/vhn-83335", "trust": 0.1, "type": "unknown" }, { "reference": "https://vulmon.com/exploitdetails?qidtp=exploitdb\u0026qid=44103", "trust": 0.1, "type": "exploit" } ], "sources": [ { "db": "VULHUB", "id": "VHN-83335" }, { "db": "VULMON", "id": "CVE-2015-5374" } ] }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2015-5374", "trust": 3.9 }, { "db": "ICS CERT", "id": "ICSA-17-187-03", "trust": 2.3 }, { "db": "ICS CERT", "id": "ICSA-15-202-01", "trust": 2.3 }, { "db": "SIEMENS", "id": "SSA-732541", "trust": 2.1 }, { "db": "BID", "id": "75948", "trust": 2.1 }, { "db": "EXPLOIT-DB", "id": "44103", "trust": 1.2 }, { "db": "SIEMENS", "id": "SSA-323211", "trust": 1.2 }, { "db": "CNNVD", "id": "CNNVD-201507-644", "trust": 1.1 }, { "db": "CNVD", "id": "CNVD-2015-04733", "trust": 1.0 }, { "db": "JVNDB", "id": "JVNDB-2015-003890", "trust": 0.8 }, { "db": "CXSECURITY", "id": "WLB-2018020218", "trust": 0.6 }, { "db": "IVD", "id": "78FDECC2-A9AF-4A66-B218-01A620B751D5", "trust": 0.2 }, { "db": "IVD", "id": "820A6B4C-2351-11E6-ABEF-000C29C66E3D", "trust": 0.2 }, { "db": "PACKETSTORM", "id": "146427", "trust": 0.1 }, { "db": "SEEBUG", "id": "SSVID-89506", "trust": 0.1 }, { "db": "VULHUB", "id": "VHN-83335", "trust": 0.1 }, { "db": "VULMON", "id": "CVE-2015-5374", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "78fdecc2-a9af-4a66-b218-01a620b751d5" }, { "db": "IVD", "id": "820a6b4c-2351-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2015-04733" }, { "db": "VULHUB", "id": "VHN-83335" }, { "db": "VULMON", "id": "CVE-2015-5374" }, { "db": "BID", "id": "75948" }, { "db": "JVNDB", "id": "JVNDB-2015-003890" }, { "db": "CNNVD", "id": "CNNVD-201507-644" }, { "db": "NVD", "id": "CVE-2015-5374" } ] }, "id": "VAR-201507-0039", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "78fdecc2-a9af-4a66-b218-01a620b751d5" }, { "db": "IVD", "id": "820a6b4c-2351-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2015-04733" }, { "db": "VULHUB", "id": "VHN-83335" } ], "trust": 1.6782828066666666 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS", "Network device" ], "sub_category": null, "trust": 0.6 }, { "category": [ "ICS" ], "sub_category": null, "trust": 0.4 } ], "sources": [ { "db": "IVD", "id": "78fdecc2-a9af-4a66-b218-01a620b751d5" }, { "db": "IVD", "id": "820a6b4c-2351-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2015-04733" } ] }, "last_update_date": "2024-11-23T22:13:28.564000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-73254", "trust": 0.8, "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-732541.pdf" }, { "title": "SIPROTEC 4 denial of service vulnerability patch", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/61054" }, { "title": "Siemens SIPROTEC 4 and SIPROTEC Compact EN100 Fixes for module denial of service vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=160157" }, { "title": "The Register", "trust": 0.2, "url": "https://www.theregister.co.uk/2017/06/12/industroyer_malware/" }, { "title": "IDPS", "trust": 0.1, "url": "https://github.com/g4xyk00/IDPS " }, { "title": "CVE-2015-5374-DoS-PoC", "trust": 0.1, "url": "https://github.com/can/CVE-2015-5374-DoS-PoC " }, { "title": "", "trust": 0.1, "url": "https://github.com/khulnasoft-labs/awesome-security " }, { "title": "welivesecurity", "trust": 0.1, "url": "https://www.welivesecurity.com/2017/06/12/industroyer-biggest-threat-industrial-control-systems-since-stuxnet/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2015-04733" }, { "db": "VULMON", "id": "CVE-2015-5374" }, { "db": "JVNDB", "id": "JVNDB-2015-003890" }, { "db": "CNNVD", "id": "CNNVD-201507-644" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-19", "trust": 1.1 }, { "problemtype": "CWE-Other", "trust": 0.8 } ], "sources": [ { "db": "VULHUB", "id": "VHN-83335" }, { "db": "JVNDB", "id": "JVNDB-2015-003890" }, { "db": "NVD", "id": "CVE-2015-5374" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://ics-cert.us-cert.gov/advisories/icsa-15-202-01" }, { "trust": 2.3, "url": "https://ics-cert.us-cert.gov/advisories/icsa-17-187-03" }, { "trust": 2.1, "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-732541.pdf" }, { "trust": 1.3, "url": "https://www.exploit-db.com/exploits/44103/" }, { "trust": 1.2, "url": "http://www.securityfocus.com/bid/75948" }, { "trust": 1.2, "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-323211.pdf" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2015-5374" }, { "trust": 0.8, "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2015-5374" }, { "trust": 0.6, "url": "https://cxsecurity.com/issue/wlb-2018020218" }, { "trust": 0.3, "url": "http://w3.siemens.com/smartgrid/global/en/products-systems-solutions/protection/siprotec4/pages/overview.aspx" }, { "trust": 0.3, "url": "http://w3.siemens.com/smartgrid/global/en/products-systems-solutions/protection/siprotec-compact/pages/overview.aspx" }, { "trust": 0.3, "url": "http://www.siemens.com/" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/19.html" }, { "trust": 0.1, "url": "https://github.com/g4xyk00/idps" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "http://tools.cisco.com/security/center/viewalert.x?alertid=40100" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2015-04733" }, { "db": "VULHUB", "id": "VHN-83335" }, { "db": "VULMON", "id": "CVE-2015-5374" }, { "db": "BID", "id": "75948" }, { "db": "JVNDB", "id": "JVNDB-2015-003890" }, { "db": "CNNVD", "id": "CNNVD-201507-644" }, { "db": "NVD", "id": "CVE-2015-5374" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "78fdecc2-a9af-4a66-b218-01a620b751d5" }, { "db": "IVD", "id": "820a6b4c-2351-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2015-04733" }, { "db": "VULHUB", "id": "VHN-83335" }, { "db": "VULMON", "id": "CVE-2015-5374" }, { "db": "BID", "id": "75948" }, { "db": "JVNDB", "id": "JVNDB-2015-003890" }, { "db": "CNNVD", "id": "CNNVD-201507-644" }, { "db": "NVD", "id": "CVE-2015-5374" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2015-07-23T00:00:00", "db": "IVD", "id": "78fdecc2-a9af-4a66-b218-01a620b751d5" }, { "date": "2015-07-23T00:00:00", "db": "IVD", "id": "820a6b4c-2351-11e6-abef-000c29c66e3d" }, { "date": "2015-07-23T00:00:00", "db": "CNVD", "id": "CNVD-2015-04733" }, { "date": "2015-07-18T00:00:00", "db": "VULHUB", "id": "VHN-83335" }, { "date": "2015-07-18T00:00:00", "db": "VULMON", "id": "CVE-2015-5374" }, { "date": "2015-07-17T00:00:00", "db": "BID", "id": "75948" }, { "date": "2015-07-23T00:00:00", "db": "JVNDB", "id": "JVNDB-2015-003890" }, { "date": "2015-07-20T00:00:00", "db": "CNNVD", "id": "CNNVD-201507-644" }, { "date": "2015-07-18T10:59:04.117000", "db": "NVD", "id": "CVE-2015-5374" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2015-07-25T00:00:00", "db": "CNVD", "id": "CNVD-2015-04733" }, { "date": "2018-03-23T00:00:00", "db": "VULHUB", "id": "VHN-83335" }, { "date": "2018-03-23T00:00:00", "db": "VULMON", "id": "CVE-2015-5374" }, { "date": "2017-07-11T12:06:00", "db": "BID", "id": "75948" }, { "date": "2017-09-11T00:00:00", "db": "JVNDB", "id": "JVNDB-2015-003890" }, { "date": "2021-08-18T00:00:00", "db": "CNNVD", "id": "CNNVD-201507-644" }, { "date": "2024-11-21T02:32:54.457000", "db": "NVD", "id": "CVE-2015-5374" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201507-644" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens SIPROTEC 4 Denial of service vulnerability", "sources": [ { "db": "IVD", "id": "78fdecc2-a9af-4a66-b218-01a620b751d5" }, { "db": "IVD", "id": "820a6b4c-2351-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2015-04733" } ], "trust": 1.0 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "code problem", "sources": [ { "db": "CNNVD", "id": "CNNVD-201507-644" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.