var-201502-0367
Vulnerability from variot
Siemens SIMATIC STEP 7 (TIA Portal) before 13 SP1 uses a weak password-hash algorithm, which makes it easier for local users to determine cleartext passwords by reading a project file and conducting a brute-force attack. Siemens SIMATIC is an automation software in a single engineering environment. Siemens SIMATIC STEP 7 TIA Portal is prone to an information-disclosure vulnerability. Attackers can exploit this issue to obtain sensitive information that may lead to further attacks. Versions prior to SIMATIC STEP 7 TIA Portal V13 SP1 are vulnerable. The software provides PLC programming, design option packages, advanced drive technology and more
Show details on source website{ "affected_products": { "_id": null, "data": [ { "_id": null, "model": "simatic step 7", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "13.0" }, { "_id": null, "model": "simatic step 7", "scope": "lt", "trust": 0.8, "vendor": "siemens", "version": "13 sp1" }, { "_id": null, "model": "simatic step sp1 upd1", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "7\u003cv13" }, { "_id": null, "model": "simatic step 7", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "13.0" }, { "_id": null, "model": null, "scope": "eq", "trust": 0.4, "vendor": "simatic step 7", "version": "*" } ], "sources": [ { "db": "IVD", "id": "a1199f58-2351-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "965b79b4-7cff-4128-ba70-599b86b4f053" }, { "db": "CNVD", "id": "CNVD-2015-01199" }, { "db": "JVNDB", "id": "JVNDB-2015-001535" }, { "db": "CNNVD", "id": "CNNVD-201502-422" }, { "db": "NVD", "id": "CVE-2015-1355" } ] }, "configurations": { "_id": null, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/a:siemens:simatic_step_7", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2015-001535" } ] }, "credits": { "_id": null, "data": "Aleksandr Timorin from Positive Technologies", "sources": [ { "db": "BID", "id": "72624" } ], "trust": 0.3 }, "cve": "CVE-2015-1355", "cvss": { "_id": null, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 2.1, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 3.9, "id": "CVE-2015-1355", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "LOW", "trust": 1.8, "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 2.1, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 3.9, "id": "CNVD-2015-01199", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "LOW", "trust": 0.6, "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "IVD", "availabilityImpact": "NONE", "baseScore": 2.1, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 3.9, "id": "a1199f58-2351-11e6-abef-000c29c66e3d", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "LOW", "trust": 0.2, "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "IVD", "availabilityImpact": "NONE", "baseScore": 2.1, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 3.9, "id": "965b79b4-7cff-4128-ba70-599b86b4f053", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "LOW", "trust": 0.2, "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "NONE", "baseScore": 2.1, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 3.9, "id": "VHN-79316", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "LOW", "trust": 0.1, "vectorString": "AV:L/AC:L/AU:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2015-1355", "trust": 1.0, "value": "LOW" }, { "author": "NVD", "id": "CVE-2015-1355", "trust": 0.8, "value": "Low" }, { "author": "CNVD", "id": "CNVD-2015-01199", "trust": 0.6, "value": "LOW" }, { "author": "CNNVD", "id": "CNNVD-201502-422", "trust": 0.6, "value": "LOW" }, { "author": "IVD", "id": "a1199f58-2351-11e6-abef-000c29c66e3d", "trust": 0.2, "value": "LOW" }, { "author": "IVD", "id": "965b79b4-7cff-4128-ba70-599b86b4f053", "trust": 0.2, "value": "LOW" }, { "author": "VULHUB", "id": "VHN-79316", "trust": 0.1, "value": "LOW" } ] } ], "sources": [ { "db": "IVD", "id": "a1199f58-2351-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "965b79b4-7cff-4128-ba70-599b86b4f053" }, { "db": "CNVD", "id": "CNVD-2015-01199" }, { "db": "VULHUB", "id": "VHN-79316" }, { "db": "JVNDB", "id": "JVNDB-2015-001535" }, { "db": "CNNVD", "id": "CNNVD-201502-422" }, { "db": "NVD", "id": "CVE-2015-1355" } ] }, "description": { "_id": null, "data": "Siemens SIMATIC STEP 7 (TIA Portal) before 13 SP1 uses a weak password-hash algorithm, which makes it easier for local users to determine cleartext passwords by reading a project file and conducting a brute-force attack. Siemens SIMATIC is an automation software in a single engineering environment. Siemens SIMATIC STEP 7 TIA Portal is prone to an information-disclosure vulnerability. \nAttackers can exploit this issue to obtain sensitive information that may lead to further attacks. \nVersions prior to SIMATIC STEP 7 TIA Portal V13 SP1 are vulnerable. The software provides PLC programming, design option packages, advanced drive technology and more", "sources": [ { "db": "NVD", "id": "CVE-2015-1355" }, { "db": "JVNDB", "id": "JVNDB-2015-001535" }, { "db": "CNVD", "id": "CNVD-2015-01199" }, { "db": "BID", "id": "72624" }, { "db": "IVD", "id": "a1199f58-2351-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "965b79b4-7cff-4128-ba70-599b86b4f053" }, { "db": "VULHUB", "id": "VHN-79316" } ], "trust": 2.88 }, "external_ids": { "_id": null, "data": [ { "db": "NVD", "id": "CVE-2015-1355", "trust": 3.9 }, { "db": "SIEMENS", "id": "SSA-234789", "trust": 2.3 }, { "db": "CNNVD", "id": "CNNVD-201502-422", "trust": 1.1 }, { "db": "CNVD", "id": "CNVD-2015-01199", "trust": 1.0 }, { "db": "BID", "id": "72624", "trust": 1.0 }, { "db": "JVNDB", "id": "JVNDB-2015-001535", "trust": 0.8 }, { "db": "IVD", "id": "A1199F58-2351-11E6-ABEF-000C29C66E3D", "trust": 0.2 }, { "db": "IVD", "id": "965B79B4-7CFF-4128-BA70-599B86B4F053", "trust": 0.2 }, { "db": "PACKETSTORM", "id": "130405", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-79316", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "a1199f58-2351-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "965b79b4-7cff-4128-ba70-599b86b4f053" }, { "db": "CNVD", "id": "CNVD-2015-01199" }, { "db": "VULHUB", "id": "VHN-79316" }, { "db": "BID", "id": "72624" }, { "db": "JVNDB", "id": "JVNDB-2015-001535" }, { "db": "PACKETSTORM", "id": "130405" }, { "db": "CNNVD", "id": "CNNVD-201502-422" }, { "db": "NVD", "id": "CVE-2015-1355" } ] }, "id": "VAR-201502-0367", "iot": { "_id": null, "data": true, "sources": [ { "db": "IVD", "id": "a1199f58-2351-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "965b79b4-7cff-4128-ba70-599b86b4f053" }, { "db": "CNVD", "id": "CNVD-2015-01199" }, { "db": "VULHUB", "id": "VHN-79316" } ], "trust": 2.1 }, "iot_taxonomy": { "_id": null, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 1.0 } ], "sources": [ { "db": "IVD", "id": "a1199f58-2351-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "965b79b4-7cff-4128-ba70-599b86b4f053" }, { "db": "CNVD", "id": "CNVD-2015-01199" } ] }, "last_update_date": "2024-11-23T21:44:26.609000Z", "patch": { "_id": null, "data": [ { "title": "SSA-234789", "trust": 0.8, "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-234789.pdf" }, { "title": "Patch for Siemens SIMATIC STEP 7 sensitive information disclosure vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/55648" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2015-01199" }, { "db": "JVNDB", "id": "JVNDB-2015-001535" } ] }, "problemtype_data": { "_id": null, "data": [ { "problemtype": "CWE-310", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-79316" }, { "db": "JVNDB", "id": "JVNDB-2015-001535" }, { "db": "NVD", "id": "CVE-2015-1355" } ] }, "references": { "_id": null, "data": [ { "trust": 2.3, "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-234789.pdf" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2015-1355" }, { "trust": 0.8, "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2015-1355" }, { "trust": 0.3, "url": "http://subscriber.communications.siemens.com/" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2015-1356" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2015-1355" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2015-01199" }, { "db": "VULHUB", "id": "VHN-79316" }, { "db": "BID", "id": "72624" }, { "db": "JVNDB", "id": "JVNDB-2015-001535" }, { "db": "PACKETSTORM", "id": "130405" }, { "db": "CNNVD", "id": "CNNVD-201502-422" }, { "db": "NVD", "id": "CVE-2015-1355" } ] }, "sources": { "_id": null, "data": [ { "db": "IVD", "id": "a1199f58-2351-11e6-abef-000c29c66e3d", "ident": null }, { "db": "IVD", "id": "965b79b4-7cff-4128-ba70-599b86b4f053", "ident": null }, { "db": "CNVD", "id": "CNVD-2015-01199", "ident": null }, { "db": "VULHUB", "id": "VHN-79316", "ident": null }, { "db": "BID", "id": "72624", "ident": null }, { "db": "JVNDB", "id": "JVNDB-2015-001535", "ident": null }, { "db": "PACKETSTORM", "id": "130405", "ident": null }, { "db": "CNNVD", "id": "CNNVD-201502-422", "ident": null }, { "db": "NVD", "id": "CVE-2015-1355", "ident": null } ] }, "sources_release_date": { "_id": null, "data": [ { "date": "2015-02-27T00:00:00", "db": "IVD", "id": "a1199f58-2351-11e6-abef-000c29c66e3d", "ident": null }, { "date": "2015-02-27T00:00:00", "db": "IVD", "id": "965b79b4-7cff-4128-ba70-599b86b4f053", "ident": null }, { "date": "2015-02-27T00:00:00", "db": "CNVD", "id": "CNVD-2015-01199", "ident": null }, { "date": "2015-02-18T00:00:00", "db": "VULHUB", "id": "VHN-79316", "ident": null }, { "date": "2015-02-13T00:00:00", "db": "BID", "id": "72624", "ident": null }, { "date": "2015-02-20T00:00:00", "db": "JVNDB", "id": "JVNDB-2015-001535", "ident": null }, { "date": "2015-02-16T17:36:59", "db": "PACKETSTORM", "id": "130405", "ident": null }, { "date": "2015-02-17T00:00:00", "db": "CNNVD", "id": "CNNVD-201502-422", "ident": null }, { "date": "2015-02-18T02:59:05.737000", "db": "NVD", "id": "CVE-2015-1355", "ident": null } ] }, "sources_update_date": { "_id": null, "data": [ { "date": "2015-02-27T00:00:00", "db": "CNVD", "id": "CNVD-2015-01199", "ident": null }, { "date": "2015-02-18T00:00:00", "db": "VULHUB", "id": "VHN-79316", "ident": null }, { "date": "2015-03-08T16:01:00", "db": "BID", "id": "72624", "ident": null }, { "date": "2015-02-20T00:00:00", "db": "JVNDB", "id": "JVNDB-2015-001535", "ident": null }, { "date": "2015-03-02T00:00:00", "db": "CNNVD", "id": "CNNVD-201502-422", "ident": null }, { "date": "2024-11-21T02:25:14.520000", "db": "NVD", "id": "CVE-2015-1355", "ident": null } ] }, "threat_type": { "_id": null, "data": "local", "sources": [ { "db": "BID", "id": "72624" }, { "db": "CNNVD", "id": "CNNVD-201502-422" } ], "trust": 0.9 }, "title": { "_id": null, "data": "Siemens SIMATIC STEP 7 Sensitive Information Disclosure Vulnerability", "sources": [ { "db": "IVD", "id": "a1199f58-2351-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "965b79b4-7cff-4128-ba70-599b86b4f053" }, { "db": "CNVD", "id": "CNVD-2015-01199" } ], "trust": 1.0 }, "type": { "_id": null, "data": "encryption problem", "sources": [ { "db": "CNNVD", "id": "CNNVD-201502-422" } ], "trust": 0.6 } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…