var-201502-0270
Vulnerability from variot
Buffer overflow on Advantech EKI-1200 gateways with firmware before 1.63 allows remote attackers to execute arbitrary code via unspecified vectors. Advantech EKI-1200 Gateway is Advantech's EKI-1200 series Modbus data gateway product, which is mainly used to integrate Modbus/RTU and Modbus/ASCI serial devices into a two-way gateway based on TCP/IP network. An unknown buffer overflow vulnerability exists in the Advantech EKI-1200 Series. Advantech EKI-1200 Series is prone to an unspecified buffer-overflow vulnerability because the application fails to properly bounds-check user-supplied data before copying it into an insufficiently sized buffer. Failed exploit attempts will likely result in denial-of-service conditions
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201502-0270", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "eki-1200 gateway series", "scope": "lte", "trust": 1.0, "vendor": "advantech", "version": "1.62" }, { "model": "eki-1200 modbus gateway series", "scope": "lt", "trust": 0.8, "vendor": "advantech", "version": "1.63" }, { "model": "eki-1221", "scope": null, "trust": 0.8, "vendor": "advantech", "version": null }, { "model": "eki-1221d", "scope": null, "trust": 0.8, "vendor": "advantech", "version": null }, { "model": "eki-1222", "scope": null, "trust": 0.8, "vendor": "advantech", "version": null }, { "model": "eki-1222d", "scope": null, "trust": 0.8, "vendor": "advantech", "version": null }, { "model": "eki-1224", "scope": null, "trust": 0.8, "vendor": "advantech", "version": null }, { "model": "eki-1200 gateway", "scope": "lt", "trust": 0.6, "vendor": "advantech", "version": "1.63" }, { "model": "eki-1200 gateway series", "scope": "eq", "trust": 0.6, "vendor": "advantech", "version": "1.62" }, { "model": "eki-1200", "scope": "eq", "trust": 0.3, "vendor": "advantech", "version": "1.6" }, { "model": "eki-1200", "scope": "ne", "trust": 0.3, "vendor": "advantech", "version": "1.63" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "eki 1200 gateway series", "version": "*" } ], "sources": [ { "db": "IVD", "id": "a23796e2-2351-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2015-01247" }, { "db": "BID", "id": "72580" }, { "db": "JVNDB", "id": "JVNDB-2014-007887" }, { "db": "CNNVD", "id": "CNNVD-201502-296" }, { "db": "NVD", "id": "CVE-2014-8385" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:advantech:eki-1200_gateway_series_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/h:advantech:eki-1221", "vulnerable": true }, { "cpe22Uri": "cpe:/h:advantech:eki-1221d", "vulnerable": true }, { "cpe22Uri": "cpe:/h:advantech:eki-1222", "vulnerable": true }, { "cpe22Uri": "cpe:/h:advantech:eki-1222d", "vulnerable": true }, { "cpe22Uri": "cpe:/h:advantech:eki-1224", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2014-007887" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Enrique Nissim and Pablo Lorenzzato from Core Security Engineering Team", "sources": [ { "db": "BID", "id": "72580" }, { "db": "CNNVD", "id": "CNNVD-201502-296" } ], "trust": 0.9 }, "cve": "CVE-2014-8385", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CVE-2014-8385", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2015-01247", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "a23796e2-2351-11e6-abef-000c29c66e3d", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "VHN-76330", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2014-8385", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2014-8385", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2015-01247", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201502-296", "trust": 0.6, "value": "CRITICAL" }, { "author": "IVD", "id": "a23796e2-2351-11e6-abef-000c29c66e3d", "trust": 0.2, "value": "CRITICAL" }, { "author": "VULHUB", "id": "VHN-76330", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "IVD", "id": "a23796e2-2351-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2015-01247" }, { "db": "VULHUB", "id": "VHN-76330" }, { "db": "JVNDB", "id": "JVNDB-2014-007887" }, { "db": "CNNVD", "id": "CNNVD-201502-296" }, { "db": "NVD", "id": "CVE-2014-8385" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Buffer overflow on Advantech EKI-1200 gateways with firmware before 1.63 allows remote attackers to execute arbitrary code via unspecified vectors. Advantech EKI-1200 Gateway is Advantech\u0027s EKI-1200 series Modbus data gateway product, which is mainly used to integrate Modbus/RTU and Modbus/ASCI serial devices into a two-way gateway based on TCP/IP network. An unknown buffer overflow vulnerability exists in the Advantech EKI-1200 Series. Advantech EKI-1200 Series is prone to an unspecified buffer-overflow vulnerability because the application fails to properly bounds-check user-supplied data before copying it into an insufficiently sized buffer. Failed exploit attempts will likely result in denial-of-service conditions", "sources": [ { "db": "NVD", "id": "CVE-2014-8385" }, { "db": "JVNDB", "id": "JVNDB-2014-007887" }, { "db": "CNVD", "id": "CNVD-2015-01247" }, { "db": "BID", "id": "72580" }, { "db": "IVD", "id": "a23796e2-2351-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-76330" } ], "trust": 2.7 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2014-8385", "trust": 3.6 }, { "db": "ICS CERT", "id": "ICSA-15-041-01", "trust": 3.4 }, { "db": "BID", "id": "72580", "trust": 1.6 }, { "db": "CNNVD", "id": "CNNVD-201502-296", "trust": 0.9 }, { "db": "CNVD", "id": "CNVD-2015-01247", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2014-007887", "trust": 0.8 }, { "db": "IVD", "id": "A23796E2-2351-11E6-ABEF-000C29C66E3D", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-76330", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "a23796e2-2351-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2015-01247" }, { "db": "VULHUB", "id": "VHN-76330" }, { "db": "BID", "id": "72580" }, { "db": "JVNDB", "id": "JVNDB-2014-007887" }, { "db": "CNNVD", "id": "CNNVD-201502-296" }, { "db": "NVD", "id": "CVE-2014-8385" } ] }, "id": "VAR-201502-0270", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "a23796e2-2351-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2015-01247" }, { "db": "VULHUB", "id": "VHN-76330" } ], "trust": 1.7000000000000002 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS", "Network device" ], "sub_category": null, "trust": 0.6 }, { "category": [ "ICS" ], "sub_category": null, "trust": 0.2 } ], "sources": [ { "db": "IVD", "id": "a23796e2-2351-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2015-01247" } ] }, "last_update_date": "2024-11-23T22:27:11.774000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Modbus\u30b2\u30fc\u30c8\u30a6\u30a7\u30a4", "trust": 0.8, "url": "http://www.advantech.co.jp/products/Modbus-Gateway/sub_GF-5TZ5.aspx" }, { "title": "Firmware Ver. 1.63 for Modbus Gateway EKI-1221D-AE", "trust": 0.8, "url": "http://support.advantech.com.tw/Support/DownloadSRDetail_New.aspx?SR_ID=1-V6XOHK\u0026amp;Doc_Source=Download" }, { "title": "Patch for Unknown Buffer Overflow Vulnerability in Advantech EKI-1200 Series", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/55469" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2015-01247" }, { "db": "JVNDB", "id": "JVNDB-2014-007887" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-119", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-76330" }, { "db": "JVNDB", "id": "JVNDB-2014-007887" }, { "db": "NVD", "id": "CVE-2014-8385" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.4, "url": "https://ics-cert.us-cert.gov/advisories/icsa-15-041-01" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2014-8385" }, { "trust": 0.8, "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2014-8385" }, { "trust": 0.6, "url": "http://www.securityfocus.com/bid/72580/info" }, { "trust": 0.6, "url": "http://www.securityfocus.com/bid/72580" }, { "trust": 0.3, "url": "http://www.advantech.com" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2015-01247" }, { "db": "VULHUB", "id": "VHN-76330" }, { "db": "BID", "id": "72580" }, { "db": "JVNDB", "id": "JVNDB-2014-007887" }, { "db": "CNNVD", "id": "CNNVD-201502-296" }, { "db": "NVD", "id": "CVE-2014-8385" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "a23796e2-2351-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2015-01247" }, { "db": "VULHUB", "id": "VHN-76330" }, { "db": "BID", "id": "72580" }, { "db": "JVNDB", "id": "JVNDB-2014-007887" }, { "db": "CNNVD", "id": "CNNVD-201502-296" }, { "db": "NVD", "id": "CVE-2014-8385" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2015-02-27T00:00:00", "db": "IVD", "id": "a23796e2-2351-11e6-abef-000c29c66e3d" }, { "date": "2015-02-27T00:00:00", "db": "CNVD", "id": "CNVD-2015-01247" }, { "date": "2015-02-13T00:00:00", "db": "VULHUB", "id": "VHN-76330" }, { "date": "2015-02-10T00:00:00", "db": "BID", "id": "72580" }, { "date": "2015-02-18T00:00:00", "db": "JVNDB", "id": "JVNDB-2014-007887" }, { "date": "2015-02-13T00:00:00", "db": "CNNVD", "id": "CNNVD-201502-296" }, { "date": "2015-02-13T02:59:07.127000", "db": "NVD", "id": "CVE-2014-8385" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2015-02-27T00:00:00", "db": "CNVD", "id": "CNVD-2015-01247" }, { "date": "2015-02-13T00:00:00", "db": "VULHUB", "id": "VHN-76330" }, { "date": "2015-02-10T00:00:00", "db": "BID", "id": "72580" }, { "date": "2015-02-18T00:00:00", "db": "JVNDB", "id": "JVNDB-2014-007887" }, { "date": "2015-02-15T00:00:00", "db": "CNNVD", "id": "CNNVD-201502-296" }, { "date": "2024-11-21T02:18:59.953000", "db": "NVD", "id": "CVE-2014-8385" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201502-296" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Advantech EKI-1200 Gateway firmware buffer overflow vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2014-007887" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Buffer overflow", "sources": [ { "db": "IVD", "id": "a23796e2-2351-11e6-abef-000c29c66e3d" }, { "db": "CNNVD", "id": "CNNVD-201502-296" } ], "trust": 0.8 } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…