var-201306-0125
Vulnerability from variot
The default configuration of the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 contains a known SSH private key, which makes it easier for remote attackers to obtain root access, and spoof alerts, via an SSH session. An attacker with SSH access to a device could use the key to log in with root privileges. Multiple Vendors EAS Devices are prone to an information-disclosure vulnerability
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201306-0125",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "dasdec eas",
"scope": "eq",
"trust": 1.0,
"vendor": "digital alert",
"version": "2.0-0"
},
{
"model": "r189 one-net eas",
"scope": "eq",
"trust": 1.0,
"vendor": "monroe",
"version": "2.0-0"
},
{
"model": "dasdec eas",
"scope": "lte",
"trust": 1.0,
"vendor": "digital alert",
"version": "2.0-1"
},
{
"model": "r189 one-net eas",
"scope": "lte",
"trust": 1.0,
"vendor": "monroe",
"version": "2.0-1"
},
{
"model": null,
"scope": null,
"trust": 0.8,
"vendor": "digital alert",
"version": null
},
{
"model": null,
"scope": null,
"trust": 0.8,
"vendor": "monroe",
"version": null
},
{
"model": "dasdec",
"scope": "lt",
"trust": 0.8,
"vendor": "digital alert",
"version": "eas 2.0-2"
},
{
"model": "r189 one-net",
"scope": "lt",
"trust": 0.8,
"vendor": "monroe",
"version": "eas 2.0-2"
},
{
"model": "electronics one-net e189 emergency alert system devices",
"scope": null,
"trust": 0.6,
"vendor": "monroe",
"version": null
},
{
"model": "alert systems dasdec",
"scope": null,
"trust": 0.6,
"vendor": "digital",
"version": null
}
],
"sources": [
{
"db": "CERT/CC",
"id": "VU#662676"
},
{
"db": "CNVD",
"id": "CNVD-2013-08540"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-003170"
},
{
"db": "NVD",
"id": "CVE-2013-0137"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/h:digital_alert_systems:dasdec_eas",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/h:monroe_electronics:r189_one-net_eas",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2013-003170"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Mike Davis and Cesar Cerrudo of IOActive",
"sources": [
{
"db": "BID",
"id": "60810"
}
],
"trust": 0.3
},
"cve": "CVE-2013-0137",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CVE-2013-0137",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.8,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"availabilityRequirement": "NOT DEFINED",
"baseScore": 10.0,
"collateralDamagePotential": "LOW-MEDIUM",
"confidentialityImpact": "COMPLETE",
"confidentialityRequirement": "NOT DEFINED",
"enviromentalScore": 6.8,
"exploitability": "NOT DEFINED",
"exploitabilityScore": 10.0,
"id": "CVE-2013-0137",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"integrityRequirement": "MEDIUM",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"remediationLevel": "OFFICIAL FIX",
"reportConfidence": "CONFIRMED",
"severity": "HIGH",
"targetDistribution": "MEDIUM",
"trust": 0.8,
"userInteractionRequired": null,
"vector_string": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2013-08540",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [],
"severity": [
{
"author": "NVD",
"id": "CVE-2013-0137",
"trust": 1.6,
"value": "HIGH"
},
{
"author": "nvd@nist.gov",
"id": "CVE-2013-0137",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2013-08540",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201306-516",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CERT/CC",
"id": "VU#662676"
},
{
"db": "CNVD",
"id": "CNVD-2013-08540"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-003170"
},
{
"db": "CNNVD",
"id": "CNNVD-201306-516"
},
{
"db": "NVD",
"id": "CVE-2013-0137"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The default configuration of the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 contains a known SSH private key, which makes it easier for remote attackers to obtain root access, and spoof alerts, via an SSH session. An attacker with SSH access to a device could use the key to log in with root privileges. Multiple Vendors EAS Devices are prone to an information-disclosure vulnerability",
"sources": [
{
"db": "NVD",
"id": "CVE-2013-0137"
},
{
"db": "CERT/CC",
"id": "VU#662676"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-003170"
},
{
"db": "CNVD",
"id": "CNVD-2013-08540"
},
{
"db": "BID",
"id": "60810"
}
],
"trust": 3.15
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "CERT/CC",
"id": "VU#662676",
"trust": 3.8
},
{
"db": "NVD",
"id": "CVE-2013-0137",
"trust": 3.3
},
{
"db": "USCERT",
"id": "TA13-175A",
"trust": 1.6
},
{
"db": "BID",
"id": "60810",
"trust": 0.9
},
{
"db": "JVN",
"id": "JVNVU99235742",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2013-003170",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2013-08540",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-201306-516",
"trust": 0.6
}
],
"sources": [
{
"db": "CERT/CC",
"id": "VU#662676"
},
{
"db": "CNVD",
"id": "CNVD-2013-08540"
},
{
"db": "BID",
"id": "60810"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-003170"
},
{
"db": "CNNVD",
"id": "CNNVD-201306-516"
},
{
"db": "NVD",
"id": "CVE-2013-0137"
}
]
},
"id": "VAR-201306-0125",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2013-08540"
}
],
"trust": 1.6
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2013-08540"
}
]
},
"last_update_date": "2024-09-09T23:03:46.044000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Monroe Electronics Provides New Software Update Enhancing Security and Functionality",
"trust": 0.8,
"url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
},
{
"title": "Monroe Electronics Provides New Software Update Enhancing Security and Functionality",
"trust": 0.8,
"url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
},
{
"title": "TA13-175A",
"trust": 0.8,
"url": "http://software.fujitsu.com/jp/security/vulnerabilities/ta13-175a.html"
},
{
"title": "Patch of SSH private key information disclosure vulnerability of multiple EAS devices from multiple vendors",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/34903"
},
{
"title": "Digital Alert Systems DASDEC EAS Fixes for encryption problem vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=170990"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2013-08540"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-003170"
},
{
"db": "CNNVD",
"id": "CNNVD-201306-516"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-310",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2013-003170"
},
{
"db": "NVD",
"id": "CVE-2013-0137"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.0,
"url": "http://www.kb.cert.org/vuls/id/662676"
},
{
"trust": 2.4,
"url": "http://www.monroe-electronics.com/monroe_electronics_pdf/130604-monroe-security-pr.pdf"
},
{
"trust": 2.4,
"url": "http://www.digitalalertsystems.com/pdf/130604-monroe-security-pr.pdf"
},
{
"trust": 2.4,
"url": "http://www.kb.cert.org/vuls/id/aamn-98muk2"
},
{
"trust": 2.4,
"url": "http://www.kb.cert.org/vuls/id/aamn-98mu7h"
},
{
"trust": 1.6,
"url": "http://www.us-cert.gov/ncas/alerts/ta13-175a"
},
{
"trust": 1.6,
"url": "http://www.monroe-electronics.com/eas_pages/r189se_registration.html"
},
{
"trust": 1.0,
"url": "https://securityledger.com/2020/01/seven-years-later-scores-of-eas-systems-sit-un-patched-vulnerable/"
},
{
"trust": 0.8,
"url": "http://www.monroe-electronics.com/eas_pages/prod_r189se.html"
},
{
"trust": 0.8,
"url": "http://www.digitalalertsystems.com/products_enc-dec.html"
},
{
"trust": 0.8,
"url": "http://www.digitalalertsystems.com/pdf/wpdas-122.pdf"
},
{
"trust": 0.8,
"url": "http://www.fcc.gov/guides/emergency-alert-system-eas"
},
{
"trust": 0.8,
"url": "http://www.ioactive.com/news-events/ioactive_uncovers_vulnerabilities_in_united_states_emergency_alerting_system.html"
},
{
"trust": 0.8,
"url": "http://www.ioactive.com/pdfs/ioactive_dasdec_vulnerabilities.pdf"
},
{
"trust": 0.8,
"url": "http://blog.ioactive.com/2013/10/strike-two-for-emergency-alerting.html"
},
{
"trust": 0.8,
"url": "http://blog.ioactive.com/2013/07/why-vendor-openness-still-matters.html"
},
{
"trust": 0.8,
"url": "http://www.commlawblog.com/2013/02/articles/broadcast/fcc-urges-broadcasters-to-secure-eas-equipment/"
},
{
"trust": 0.8,
"url": "http://www.broadcastlawblog.com/2013/02/articles/emergency-communications/hackers-use-eas-to-send-alert-of-zombie-attack-fcc-issues-urgent-warning-to-broadcasters-to-secure-their-eas-systems/"
},
{
"trust": 0.8,
"url": "http://www.radioworld.com/article/eas-hack-cap-not-the-issue-internet-security-is/217746"
},
{
"trust": 0.8,
"url": "http://www.radioworld.com/article/stations-urged-to-protect-their-eas/217746"
},
{
"trust": 0.8,
"url": "http://transition.fcc.gov/pshs/techtopics/techtopics21.html"
},
{
"trust": 0.8,
"url": "http://www.thebdr.net/articles/fcc/eas/eas.html"
},
{
"trust": 0.8,
"url": "http://www.thebdr.net/articles/fcc/eas/eas-q5.pdf"
},
{
"trust": 0.8,
"url": "http://cwe.mitre.org/data/definitions/798.html"
},
{
"trust": 0.8,
"url": "http://cwe.mitre.org/data/definitions/532.html"
},
{
"trust": 0.8,
"url": "http://cwe.mitre.org/data/definitions/341.html"
},
{
"trust": 0.8,
"url": "http://cwe.mitre.org/data/definitions/320.html"
},
{
"trust": 0.8,
"url": "http://cwe.mitre.org/data/definitions/321.html"
},
{
"trust": 0.8,
"url": "http://www.cert.org/downloads/vuls/662676/ssh-key-test.sh"
},
{
"trust": 0.8,
"url": "https://raw.github.com/aspiers/ssh-config/master/bin/ssh-list-pubkeys"
},
{
"trust": 0.8,
"url": "http://www.wired.com/threatlevel/2013/07/eas-holes/"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2013-0137"
},
{
"trust": 0.8,
"url": "http://jvn.jp/cert/jvnvu99235742"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2013-0137"
}
],
"sources": [
{
"db": "CERT/CC",
"id": "VU#662676"
},
{
"db": "CNVD",
"id": "CNVD-2013-08540"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-003170"
},
{
"db": "CNNVD",
"id": "CNNVD-201306-516"
},
{
"db": "NVD",
"id": "CVE-2013-0137"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CERT/CC",
"id": "VU#662676"
},
{
"db": "CNVD",
"id": "CNVD-2013-08540"
},
{
"db": "BID",
"id": "60810"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-003170"
},
{
"db": "CNNVD",
"id": "CNNVD-201306-516"
},
{
"db": "NVD",
"id": "CVE-2013-0137"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2013-06-26T00:00:00",
"db": "CERT/CC",
"id": "VU#662676"
},
{
"date": "2013-07-02T00:00:00",
"db": "CNVD",
"id": "CNVD-2013-08540"
},
{
"date": "2013-06-26T00:00:00",
"db": "BID",
"id": "60810"
},
{
"date": "2013-07-02T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2013-003170"
},
{
"date": "2013-06-30T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201306-516"
},
{
"date": "2013-06-30T19:28:09.593000",
"db": "NVD",
"id": "CVE-2013-0137"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2014-05-07T00:00:00",
"db": "CERT/CC",
"id": "VU#662676"
},
{
"date": "2013-08-28T00:00:00",
"db": "CNVD",
"id": "CNVD-2013-08540"
},
{
"date": "2013-06-26T00:00:00",
"db": "BID",
"id": "60810"
},
{
"date": "2013-07-02T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2013-003170"
},
{
"date": "2021-11-24T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201306-516"
},
{
"date": "2020-01-29T18:15:11.560000",
"db": "NVD",
"id": "CVE-2013-0137"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201306-516"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Digital Alert Systems DASDEC and Monroe Electronics R189 One-Net firmware exposes private root SSH key",
"sources": [
{
"db": "CERT/CC",
"id": "VU#662676"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "encryption problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201306-516"
}
],
"trust": 0.6
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…