ssa-508677
Vulnerability from csaf_siemens
Published
2023-06-13 00:00
Modified
2023-06-13 00:00
Summary
SSA-508677: Use of Obsolete Function Vulnerability in SIMATIC WinCC before V8
Notes
Summary
Before SIMATIC WinCC V8, legacy OPC services (OPC DA (Data Access), OPC HDA (Historical Data Access), and OPC AE (Alarms & Events)) were used per default. These
services were designed on top of the Windows ActiveX and DCOM mechanisms and do not implement state-of-the-art security mechanisms for authentication and encryption of contents.
Starting with WinCC V8.0 the legacy OPC services are no longer enabled by default in new installations. Siemens recommends to use OPC UA instead and to disable the legacy OPC services. For deployments where the legacy OPC services are still in use, ensure that only trusted users are part of the SIMATIC HMI group.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "Before SIMATIC WinCC V8, legacy OPC services (OPC DA (Data Access), OPC HDA (Historical Data Access), and OPC AE (Alarms \u0026 Events)) were used per default. These\nservices were designed on top of the Windows ActiveX and DCOM mechanisms and do not implement state-of-the-art security mechanisms for authentication and encryption of contents.\n\nStarting with WinCC V8.0 the legacy OPC services are no longer enabled by default in new installations. Siemens recommends to use OPC UA instead and to disable the legacy OPC services. For deployments where the legacy OPC services are still in use, ensure that only trusted users are part of the SIMATIC HMI group.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-508677: Use of Obsolete Function Vulnerability in SIMATIC WinCC before V8 - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-508677.html"
},
{
"category": "self",
"summary": "SSA-508677: Use of Obsolete Function Vulnerability in SIMATIC WinCC before V8 - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-508677.json"
},
{
"category": "self",
"summary": "SSA-508677: Use of Obsolete Function Vulnerability in SIMATIC WinCC before V8 - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-508677.pdf"
},
{
"category": "self",
"summary": "SSA-508677: Use of Obsolete Function Vulnerability in SIMATIC WinCC before V8 - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-508677.txt"
}
],
"title": "SSA-508677: Use of Obsolete Function Vulnerability in SIMATIC WinCC before V8",
"tracking": {
"current_release_date": "2023-06-13T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-508677",
"initial_release_date": "2023-06-13T00:00:00Z",
"revision_history": [
{
"date": "2023-06-13T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
}
],
"status": "interim",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC NET PC Software V14",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "SIMATIC NET PC Software V14"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC NET PC Software V15",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "SIMATIC NET PC Software V15"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC PCS 7 V8.2",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "SIMATIC PCS 7 V8.2"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC PCS 7 V9.0",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "SIMATIC PCS 7 V9.0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC PCS 7 V9.1",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "SIMATIC PCS 7 V9.1"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV8.0",
"product": {
"name": "SIMATIC WinCC",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SINAUT Software ST7sc",
"product_id": "7"
}
}
],
"category": "product_name",
"name": "SINAUT Software ST7sc"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2023-28829",
"cwe": {
"id": "CWE-477",
"name": "Use of Obsolete Function"
},
"notes": [
{
"category": "summary",
"text": "Before SIMATIC WinCC V8, legacy OPC services (OPC DA (Data Access), OPC HDA (Historical Data Access), and OPC AE (Alarms \u0026 Events)) were used per default. These\r\nservices were designed on top of the Windows ActiveX and DCOM mechanisms and do not implement state-of-the-art security mechanisms for authentication and encryption of contents.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Disable the legacy OPC DA/HDA/AE services and switch to OPC UA, if possible",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7"
]
},
{
"category": "mitigation",
"details": "Ensure that only trusted users are part of the SIMATIC HMI group",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"7"
]
},
{
"category": "vendor_fix",
"details": "Update to V8.0 or later version",
"product_ids": [
"6"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109816599/"
},
{
"category": "workaround",
"details": "SINATIC NET PC Software: Ensure that only trusted users are part of the SIMATIC Net group",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.9,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:U/C:L/I:L/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7"
]
}
],
"title": "CVE-2023-28829"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…