ssa-267056
Vulnerability from csaf_siemens
Published
2025-11-11 00:00
Modified
2025-11-11 00:00
Summary
SSA-267056: Multiple Vulnerabilities in LOGO! 8 BM Devices
Notes
Summary
LOGO! 8 BM (incl. SIPLUS variants) contains multiple vulnerabilities. These could allow an attacker to execute code remotely, put the device into a denial of service state, or change the behavior of the device.
Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "LOGO! 8 BM (incl. SIPLUS variants) contains multiple vulnerabilities. These could allow an attacker to execute code remotely, put the device into a denial of service state, or change the behavior of the device.\n\nSiemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-267056: Multiple Vulnerabilities in LOGO! 8 BM Devices - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-267056.html"
},
{
"category": "self",
"summary": "SSA-267056: Multiple Vulnerabilities in LOGO! 8 BM Devices - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-267056.json"
}
],
"title": "SSA-267056: Multiple Vulnerabilities in LOGO! 8 BM Devices",
"tracking": {
"current_release_date": "2025-11-11T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-267056",
"initial_release_date": "2025-11-11T00:00:00Z",
"revision_history": [
{
"date": "2025-11-11T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
}
],
"status": "interim",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "LOGO! 12/24RCE (6ED1052-1MD08-0BA2)",
"product_id": "1",
"product_identification_helper": {
"model_numbers": [
"6ED1052-1MD08-0BA2"
]
}
}
}
],
"category": "product_name",
"name": "LOGO! 12/24RCE (6ED1052-1MD08-0BA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "LOGO! 12/24RCEo (6ED1052-2MD08-0BA2)",
"product_id": "2",
"product_identification_helper": {
"model_numbers": [
"6ED1052-2MD08-0BA2"
]
}
}
}
],
"category": "product_name",
"name": "LOGO! 12/24RCEo (6ED1052-2MD08-0BA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "LOGO! 230RCE (6ED1052-1FB08-0BA2)",
"product_id": "3",
"product_identification_helper": {
"model_numbers": [
"6ED1052-1FB08-0BA2"
]
}
}
}
],
"category": "product_name",
"name": "LOGO! 230RCE (6ED1052-1FB08-0BA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "LOGO! 230RCEo (6ED1052-2FB08-0BA2)",
"product_id": "4",
"product_identification_helper": {
"model_numbers": [
"6ED1052-2FB08-0BA2"
]
}
}
}
],
"category": "product_name",
"name": "LOGO! 230RCEo (6ED1052-2FB08-0BA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "LOGO! 24CE (6ED1052-1CC08-0BA2)",
"product_id": "5",
"product_identification_helper": {
"model_numbers": [
"6ED1052-1CC08-0BA2"
]
}
}
}
],
"category": "product_name",
"name": "LOGO! 24CE (6ED1052-1CC08-0BA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "LOGO! 24CEo (6ED1052-2CC08-0BA2)",
"product_id": "6",
"product_identification_helper": {
"model_numbers": [
"6ED1052-2CC08-0BA2"
]
}
}
}
],
"category": "product_name",
"name": "LOGO! 24CEo (6ED1052-2CC08-0BA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "LOGO! 24RCE (6ED1052-1HB08-0BA2)",
"product_id": "7",
"product_identification_helper": {
"model_numbers": [
"6ED1052-1HB08-0BA2"
]
}
}
}
],
"category": "product_name",
"name": "LOGO! 24RCE (6ED1052-1HB08-0BA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "LOGO! 24RCEo (6ED1052-2HB08-0BA2)",
"product_id": "8",
"product_identification_helper": {
"model_numbers": [
"6ED1052-2HB08-0BA2"
]
}
}
}
],
"category": "product_name",
"name": "LOGO! 24RCEo (6ED1052-2HB08-0BA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2)",
"product_id": "9",
"product_identification_helper": {
"model_numbers": [
"6AG1052-1MD08-7BA2"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2)",
"product_id": "10",
"product_identification_helper": {
"model_numbers": [
"6AG1052-2MD08-7BA2"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2)",
"product_id": "11",
"product_identification_helper": {
"model_numbers": [
"6AG1052-1FB08-7BA2"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2)",
"product_id": "12",
"product_identification_helper": {
"model_numbers": [
"6AG1052-2FB08-7BA2"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2)",
"product_id": "13",
"product_identification_helper": {
"model_numbers": [
"6AG1052-1CC08-7BA2"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2)",
"product_id": "14",
"product_identification_helper": {
"model_numbers": [
"6AG1052-2CC08-7BA2"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2)",
"product_id": "15",
"product_identification_helper": {
"model_numbers": [
"6AG1052-1HB08-7BA2"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2)",
"product_id": "16",
"product_identification_helper": {
"model_numbers": [
"6AG1052-2HB08-7BA2"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2)"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2025-40815",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "Affected devices do not properly validate the structure of TCP packets in several methods. This could allow an attacker to cause buffer overflows, get control over the instruction counter and run custom code.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Protect the LSC access to the device with a strong password.",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16"
]
},
{
"category": "none_available",
"details": "Currently no fix is available",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16"
]
}
],
"title": "CVE-2025-40815"
},
{
"cve": "CVE-2025-40816",
"cwe": {
"id": "CWE-306",
"name": "Missing Authentication for Critical Function"
},
"notes": [
{
"category": "summary",
"text": "Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Restrict network access to port 10006/udp to trusted IP addresses.",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16"
]
}
],
"title": "CVE-2025-40816"
},
{
"cve": "CVE-2025-40817",
"cwe": {
"id": "CWE-306",
"name": "Missing Authentication for Critical Function"
},
"notes": [
{
"category": "summary",
"text": "Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to change time of the device, which means the device could behave differently.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Restrict network access to port 10006/udp to trusted IP addresses.",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16"
]
}
],
"title": "CVE-2025-40817"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…