ssa-064257
Vulnerability from csaf_siemens
Published
2024-11-12 00:00
Modified
2024-11-12 00:00
Summary
SSA-064257: Privilege Escalation Vulnerability in SIPORT Before V3.4.0
Notes
Summary
SIPORT before V3.4.0 contains a privilege escalation vulnerability which could allow a local attacker with an unprivileged account to override or modify the service executable and subsequently gain elevated privileges.
Siemens has released a new version for SIPORT and recommends to update to the latest version.
General Recommendations
As a general security measure Siemens strongly recommends to protect network access to affected products with appropriate mechanisms. It is advised to follow recommended security practices in order to run the devices in a protected IT environment.
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)", "tlp": { "label": "WHITE" } }, "lang": "en", "notes": [ { "category": "summary", "text": "SIPORT before V3.4.0 contains a privilege escalation vulnerability which could allow a local attacker with an unprivileged account to override or modify the service executable and subsequently gain elevated privileges.\n\nSiemens has released a new version for SIPORT and recommends to update to the latest version.", "title": "Summary" }, { "category": "general", "text": "As a general security measure Siemens strongly recommends to protect network access to affected products with appropriate mechanisms. It is advised to follow recommended security practices in order to run the devices in a protected IT environment.", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.", "title": "Terms of Use" } ], "publisher": { "category": "vendor", "contact_details": "productcert@siemens.com", "name": "Siemens ProductCERT", "namespace": "https://www.siemens.com" }, "references": [ { "category": "self", "summary": "SSA-064257: Privilege Escalation Vulnerability in SIPORT Before V3.4.0 - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-064257.html" }, { "category": "self", "summary": "SSA-064257: Privilege Escalation Vulnerability in SIPORT Before V3.4.0 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-064257.json" } ], "title": "SSA-064257: Privilege Escalation Vulnerability in SIPORT Before V3.4.0", "tracking": { "current_release_date": "2024-11-12T00:00:00Z", "generator": { "engine": { "name": "Siemens ProductCERT CSAF Generator", "version": "1" } }, "id": "SSA-064257", "initial_release_date": "2024-11-12T00:00:00Z", "revision_history": [ { "date": "2024-11-12T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "interim", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV3.4.0", "product": { "name": "SIPORT", "product_id": "1" } } ], "category": "product_name", "name": "SIPORT" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2024-47783", "cwe": { "id": "CWE-732", "name": "Incorrect Permission Assignment for Critical Resource" }, "notes": [ { "category": "summary", "text": "The affected application improperly assigns file permissions to installation folders.\r\n\r\nThis could allow a local attacker with an unprivileged account to override or modify the service executables and subsequently gain elevated privileges.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "mitigation", "details": "Remove write permissions for non-administrative users on files and folders located under the installation path", "product_ids": [ "1" ] }, { "category": "vendor_fix", "details": "Update to V3.4.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109826608/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-47783" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.