Vulnerability from csaf_ncscnl
Published
2024-10-18 09:10
Modified
2024-10-18 09:10
Summary
Kwetsbaarheden verholpen in SolarWinds Serv-U

Notes

The Netherlands Cyber Security Center (henceforth: NCSC-NL) maintains this page to enhance access to its information and security advisories. The use of this security advisory is subject to the following terms and conditions: NCSC-NL makes every reasonable effort to ensure that the content of this page is kept up to date, and that it is accurate and complete. Nevertheless, NCSC-NL cannot entirely rule out the possibility of errors, and therefore cannot give any warranty in respect of its completeness, accuracy or continuous keeping up-to-date. The information contained in this security advisory is intended solely for the purpose of providing general information to professional users. No rights can be derived from the information provided therein. NCSC-NL and the Kingdom of the Netherlands assume no legal liability or responsibility for any damage resulting from either the use or inability of use of this security advisory. This includes damage resulting from the inaccuracy of incompleteness of the information contained in the advisory. This security advisory is subject to Dutch law. All disputes related to or arising from the use of this advisory will be submitted to the competent court in The Hague. This choice of means also applies to the court in summary proceedings.
Feiten
SolarWinds heeft kwetsbaarheden verholpen in Serv-U.
Interpretaties
Een kwaadwillende kan de kwetsbaarheid met kenmerk CVE-2024-45711 misbruiken om middels path-traversal willekeurige code uit te voeren op het onderliggende systeem. Voor succesvol misbruik moet de kwaadwillende voorafgaand geauthenticeerd zijn en code-uitvoer is mogelijk afhankelijk van de rechten van het account. Ook kan de kwaadwillende de kwetsbaarheid met kenmerk CVE-2024-45714 misbruiken om een Cross-Site-Scripting-aanval uit te voeren. Een dergelijke aanval kan leiden tot uitvoer van willekeurige code in de browser van het slachtoffer, of toegang tot gegevens in de context van de browser van het slachtoffer. Het is aannemelijk dat de kwetsbaarheden in keten kunnen worden misbruikt. Door de aard van het systeem is daarmee niet uit te sluiten dat eventuele code-uitvoer via Cross-Site-Scripting met verhoogde rechten plaatsvindt. Omdat misbruik dan via social engineering plaats kan vinden, hoeft de kwaadwillende niet over voorafgaande authenticatie te beschikken, maar maakt de kwaadwillende misbruik van de rechten van het slachtoffer.
Oplossingen
SolarWinds heeft updates uitgebracht om de kwetsbaarheden te verhelpen. Zie bijgevoegde referenties voor meer informatie.
Kans
medium
Schade
high
CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')



{
  "document": {
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "tlp": {
        "label": "WHITE"
      }
    },
    "lang": "nl",
    "notes": [
      {
        "category": "legal_disclaimer",
        "text": "The Netherlands Cyber Security Center (henceforth: NCSC-NL) maintains this page to enhance access to its information and security advisories. The use of this security advisory is subject to the following terms and conditions:\n\n    NCSC-NL makes every reasonable effort to ensure that the content of this page is kept up to date, and that it is accurate and complete. Nevertheless, NCSC-NL cannot entirely rule out the possibility of errors, and therefore cannot give any warranty in respect of its completeness, accuracy or continuous keeping up-to-date. The information contained in this security advisory is intended solely for the purpose of providing general information to professional users. No rights can be derived from the information provided therein.\n\n    NCSC-NL and the Kingdom of the Netherlands assume no legal liability or responsibility for any damage resulting from either the use or inability of use of this security advisory. This includes damage resulting from the inaccuracy of incompleteness of the information contained in the advisory.\n    This security advisory is subject to Dutch law. All disputes related to or arising from the use of this advisory will be submitted to the competent court in The Hague. This choice of means also applies to the court in summary proceedings."
      },
      {
        "category": "description",
        "text": "SolarWinds heeft kwetsbaarheden verholpen in Serv-U.",
        "title": "Feiten"
      },
      {
        "category": "description",
        "text": "Een kwaadwillende kan de kwetsbaarheid met kenmerk CVE-2024-45711 misbruiken om middels path-traversal willekeurige code uit te voeren op het onderliggende systeem.\nVoor succesvol misbruik moet de kwaadwillende voorafgaand geauthenticeerd zijn en code-uitvoer is mogelijk afhankelijk van de rechten van het account.\n\nOok kan de kwaadwillende de kwetsbaarheid met kenmerk CVE-2024-45714 misbruiken om een Cross-Site-Scripting-aanval uit te voeren. Een dergelijke aanval kan leiden tot uitvoer van willekeurige code in de browser van het slachtoffer, of toegang tot gegevens in de context van de browser van het slachtoffer.\n\nHet is aannemelijk dat de kwetsbaarheden in keten kunnen worden misbruikt. Door de aard van het systeem is daarmee niet uit te sluiten dat eventuele code-uitvoer via Cross-Site-Scripting met verhoogde rechten plaatsvindt. Omdat misbruik dan via social engineering plaats kan vinden, hoeft de kwaadwillende niet over voorafgaande authenticatie te beschikken, maar maakt de kwaadwillende misbruik van de rechten van het slachtoffer.",
        "title": "Interpretaties"
      },
      {
        "category": "description",
        "text": "SolarWinds heeft updates uitgebracht om de kwetsbaarheden te verhelpen. Zie bijgevoegde referenties voor meer informatie.",
        "title": "Oplossingen"
      },
      {
        "category": "general",
        "text": "medium",
        "title": "Kans"
      },
      {
        "category": "general",
        "text": "high",
        "title": "Schade"
      },
      {
        "category": "general",
        "text": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
        "title": "CWE-79"
      },
      {
        "category": "general",
        "text": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
        "title": "CWE-22"
      }
    ],
    "publisher": {
      "category": "coordinator",
      "contact_details": "cert@ncsc.nl",
      "name": "Nationaal Cyber Security Centrum",
      "namespace": "https://www.ncsc.nl/"
    },
    "references": [
      {
        "category": "external",
        "summary": "Reference - cveprojectv5; nvd",
        "url": "https://www.solarwinds.com/trust-center/security-advisories/CVE-2024-45711"
      },
      {
        "category": "external",
        "summary": "Reference - cveprojectv5; nvd",
        "url": "https://www.solarwinds.com/trust-center/security-advisories/CVE-2024-45714"
      }
    ],
    "title": "Kwetsbaarheden verholpen in SolarWinds Serv-U",
    "tracking": {
      "current_release_date": "2024-10-18T09:10:48.856424Z",
      "id": "NCSC-2024-0421",
      "initial_release_date": "2024-10-18T09:10:48.856424Z",
      "revision_history": [
        {
          "date": "2024-10-18T09:10:48.856424Z",
          "number": "0",
          "summary": "Initiele versie"
        }
      ],
      "status": "final",
      "version": "1.0.0"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "category": "product_name",
            "name": "serv-u",
            "product": {
              "name": "serv-u",
              "product_id": "CSAFPID-2765",
              "product_identification_helper": {
                "cpe": "cpe:2.3:a:solarwinds:serv-u:*:*:*:*:*:*:*:*"
              }
            }
          },
          {
            "category": "product_name",
            "name": "serv-u",
            "product": {
              "name": "serv-u",
              "product_id": "CSAFPID-1674745",
              "product_identification_helper": {
                "cpe": "cpe:2.3:a:solarwinds:serv-u:15.4.2_hf2:*:*:*:*:*:*:*"
              }
            }
          },
          {
            "category": "product_name",
            "name": "serv-u",
            "product": {
              "name": "serv-u",
              "product_id": "CSAFPID-1674928",
              "product_identification_helper": {
                "cpe": "cpe:2.3:a:solarwinds:serv-u:15.4.2_hf_2:*:*:*:*:*:*:*"
              }
            }
          },
          {
            "category": "product_name",
            "name": "serv-u",
            "product": {
              "name": "serv-u",
              "product_id": "CSAFPID-1673897",
              "product_identification_helper": {
                "cpe": "cpe:2.3:a:solarwinds:serv-u:serv-u_15.4.2_hf2_and_previous_versions:*:*:*:*:*:*:*"
              }
            }
          },
          {
            "category": "product_name",
            "name": "serv-u",
            "product": {
              "name": "serv-u",
              "product_id": "CSAFPID-1673896",
              "product_identification_helper": {
                "cpe": "cpe:2.3:a:solarwinds:serv-u:serv-u_15.4.2_hf_2_and_previous_versions:*:*:*:*:*:*:*"
              }
            }
          },
          {
            "category": "product_name",
            "name": "solarwinds_serv-u_managed_file_transfer_server__15.5",
            "product": {
              "name": "solarwinds_serv-u_managed_file_transfer_server__15.5",
              "product_id": "CSAFPID-1676135",
              "product_identification_helper": {
                "cpe": "cpe:2.3:a:solarwinds:solarwinds_serv-u_managed_file_transfer_server__15.5:*:*:*:*:*:*:*:*"
              }
            }
          }
        ],
        "category": "vendor",
        "name": "solarwinds"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2024-45711",
      "cwe": {
        "id": "CWE-22",
        "name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
      },
      "notes": [
        {
          "category": "other",
          "text": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
          "title": "CWE-22"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-1673896",
          "CSAFPID-1676135",
          "CSAFPID-2765"
        ]
      },
      "references": [
        {
          "category": "self",
          "summary": "CVE-2024-45711",
          "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-45711.json"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-1673896",
            "CSAFPID-1676135",
            "CSAFPID-2765"
          ]
        }
      ],
      "title": "CVE-2024-45711"
    },
    {
      "cve": "CVE-2024-45714",
      "cwe": {
        "id": "CWE-79",
        "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
      },
      "notes": [
        {
          "category": "other",
          "text": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
          "title": "CWE-79"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-1673897",
          "CSAFPID-1676135"
        ]
      },
      "references": [
        {
          "category": "self",
          "summary": "CVE-2024-45714",
          "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-45714.json"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 4.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-1673897",
            "CSAFPID-1676135"
          ]
        }
      ],
      "title": "CVE-2024-45714"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.