icsa-25-037-03
Vulnerability from csaf_cisa
Published
2025-01-10 04:30
Modified
2025-01-10 03:30
Summary
ABB Drive Composer

Notes

Summary
An update is available that resolves vulnerability in the product versions as affected in this advisory. An attacker who successfully exploits the vulnerability could get unauthorized access to the file system on the host machine. This can lead to the execution of arbitrary code, data leakage, or even complete system compromise.
General security recommendations
For any installation of software-related ABB products we strongly recommend the following (non-exhaustive) list of cyber security practices: Isolate special purpose networks (e.g. for automation systems) and remote devices behind firewalls and separate them from any general-purpose network (e.g. office or home networks). Install physical controls so no unauthorized personnel can access your devices, components, peripheral equipment, and networks. Never connect programming software or computers containing programing software to any net-work other than the network for the devices that it is intended for. Scan all data imported into your environment before use to detect potential malware infections. Minimize network exposure for all applications and endpoints to ensure that they are not accessible from the Internet unless they are designed for such exposure and the intended use requires such. Ensure all nodes are always up to date in terms of installed software, operating system, and firmware patches as well as anti-virus and firewall. When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. More information on recommended practices can be found in the reference section (3AXD10000492137)
Support
For additional instructions and support please contact your local ABB service organization. For contact information, see www.abb.com/contactcenters. Information about ABB’s cyber security program and capabilities can be found at www.abb.com/cybersecurity.
Notice
The information in this document is subject to change without notice, and should not be construed as a commitment by ABB. ABB provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall ABB or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if ABB or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from ABB, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners.
Mitigating factors
The identified vulnerability could be exploited when a user opens a tampered Drive Composer file (such as a support package or parameter backup). Users are advised to only open Drive Composer files received from trusted sources and ensure they are free from any alterations by scanning the files through a malware scanner. Refer to section “General security recommendations” for further advise on how to keep your system secure.
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Advisory Conversion Disclaimer
This CISA CSAF advisory was converted from ABB PSIRT's CSAF advisory.
Critical infrastructure sectors
Critical Manufacturing
Countries/areas deployed
Worldwide
Company headquarters location
Switzerland
Recommended Practices
CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.
Recommended Practices
Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.
Recommended Practices
Locate control system networks and remote devices behind firewalls and isolate them from business networks.
Recommended Practices
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.



{
  "document": {
    "acknowledgments": [
      {
        "organization": "ABB PSIRT",
        "summary": "reporting this vulnerability to CISA."
      }
    ],
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited",
      "tlp": {
        "label": "WHITE",
        "url": "https://us-cert.cisa.gov/tlp/"
      }
    },
    "lang": "en",
    "notes": [
      {
        "category": "summary",
        "text": "An update is available that resolves vulnerability in the product versions as affected in this advisory.\nAn attacker who successfully exploits the vulnerability could get unauthorized access to the file system\non the host machine. This can lead to the execution of arbitrary code, data leakage, or even complete\nsystem compromise.",
        "title": "Summary"
      },
      {
        "category": "other",
        "text": "For any installation of software-related ABB products we strongly recommend the following (non-exhaustive) list of cyber security practices:\nIsolate special purpose networks (e.g. for automation systems) and remote devices behind firewalls and\nseparate them from any general-purpose network (e.g. office or home networks).\nInstall physical controls so no unauthorized personnel can access your devices, components, peripheral\nequipment, and networks.\nNever connect programming software or computers containing programing software to any net-work\nother than the network for the devices that it is intended for.\nScan all data imported into your environment before use to detect potential malware infections.\nMinimize network exposure for all applications and endpoints to ensure that they are not accessible\nfrom the Internet unless they are designed for such exposure and the intended use requires such.\nEnsure all nodes are always up to date in terms of installed software, operating system, and firmware\npatches as well as anti-virus and firewall.\nWhen remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available.\nAlso, understand that VPNs are only as secure as the connected devices.\nMore information on recommended practices can be found in the reference section (3AXD10000492137)\n",
        "title": "General security recommendations"
      },
      {
        "category": "other",
        "text": "For additional instructions and support please contact your local ABB service organization. For contact\ninformation, see www.abb.com/contactcenters.\nInformation about ABB\u2019s cyber security program and capabilities can be found at www.abb.com/cybersecurity.\n",
        "title": "Support"
      },
      {
        "category": "legal_disclaimer",
        "text": "The information in this document is subject to change without notice, and should not be construed as a\ncommitment by ABB.\nABB provides no warranty, express or implied, including warranties of merchantability and fitness for a\nparticular purpose, for the information contained in this document, and assumes no responsibility for\nany errors that may appear in this document. In no event shall ABB or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of\nthis document, or from the use of any hardware or software described in this document, even if ABB or\nits suppliers have been advised of the possibility of such damages.\nThis document and parts hereof must not be reproduced or copied without written permission from\nABB, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose.\nAll rights to registrations and trademarks reside with their respective owners.\n",
        "title": "Notice"
      },
      {
        "category": "general",
        "text": "The identified vulnerability could be exploited when a user opens a tampered Drive Composer file (such\nas a support package or parameter backup). Users are advised to only open Drive Composer files received from trusted sources and ensure they are free from any alterations by scanning the files through\na malware scanner.\nRefer to section \u201cGeneral security recommendations\u201d for further advise on how to keep your system secure.",
        "title": "Mitigating factors"
      },
      {
        "category": "legal_disclaimer",
        "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
        "title": "Legal Notice"
      },
      {
        "category": "other",
        "text": "This CISA CSAF advisory was converted from ABB PSIRT\u0027s CSAF advisory.",
        "title": "Advisory Conversion Disclaimer"
      },
      {
        "category": "other",
        "text": "Critical Manufacturing",
        "title": "Critical infrastructure sectors"
      },
      {
        "category": "other",
        "text": "Worldwide",
        "title": "Countries/areas deployed"
      },
      {
        "category": "other",
        "text": "Switzerland",
        "title": "Company headquarters location"
      },
      {
        "category": "general",
        "text": "CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
        "title": "Recommended Practices"
      }
    ],
    "publisher": {
      "category": "other",
      "contact_details": "central@cisa.dhs.gov",
      "name": "CISA",
      "namespace": "https://www.cisa.gov/"
    },
    "references": [
      {
        "category": "self",
        "summary": "ICS Advisory ICSA-25-037-03 JSON",
        "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-037-03.json"
      },
      {
        "summary": "Technical Guide - Cybersecurity for ABB Drives (3AXD10000492137)",
        "url": "https://search.abb.com/library/Download.aspx?DocumentID=3AXD10000492137\u0026LanguageCode=en\u0026DocumentPartId=1\u0026Action=Launch"
      },
      {
        "summary": "ABB CYBERSECURITY ADVISORY - PDF version ",
        "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108470A5466\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
      },
      {
        "summary": "Directory Traversal vulnerability in DotNetZip",
        "url": "https://nvd.nist.gov/vuln/detail/CVE-2024-48510"
      },
      {
        "category": "self",
        "summary": "ICS Advisory ICSA-25-037-03 - Web Version",
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-037-03"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/topics/industrial-control-systems"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
      }
    ],
    "title": "ABB Drive Composer",
    "tracking": {
      "current_release_date": "2025-01-10T03:30:00.000000Z",
      "generator": {
        "date": "2025-01-18T03:38:19.141000Z",
        "engine": {
          "name": "CISA CSAF Generator",
          "version": "1.0.0"
        }
      },
      "id": "ICSA-25-037-03",
      "initial_release_date": "2025-01-10T04:30:00.000000Z",
      "revision_history": [
        {
          "date": "2025-01-10T06:30:00.000000Z",
          "number": "1.0.0",
          "summary": "Initial version"
        }
      ],
      "status": "final",
      "version": "1.0.0"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c=2.9.0.1",
                "product": {
                  "name": "Drive Composer entry \u003c= 2.9.0.1",
                  "product_id": "CSAFPID-0001"
                }
              },
              {
                "category": "product_version",
                "name": "2.9.1",
                "product": {
                  "name": "Drive Composer entry 2.9.1",
                  "product_id": "CSAFPID-0002"
                }
              }
            ],
            "category": "product_name",
            "name": "Drive Composer entry"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c=2.9.0.1",
                "product": {
                  "name": "Drive Composer pro \u003c= 2.9.0.1",
                  "product_id": "CSAFPID-0003"
                }
              },
              {
                "category": "product_version",
                "name": "2.9.1",
                "product": {
                  "name": "Drive Composer pro 2.9.1",
                  "product_id": "CSAFPID-0004"
                }
              }
            ],
            "category": "product_name",
            "name": "Drive Composer pro"
          }
        ],
        "category": "vendor",
        "name": "ABB"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2024-48510",
      "cwe": {
        "id": "CWE-22",
        "name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
      },
      "notes": [
        {
          "category": "description",
          "text": "Vulnerability in drive composer can allow attackers unauthorized access to the file system on the host\nmachine. An attacker can exploit this flaw to run malicious code, which could lead to the compromise of\nthe affected system.",
          "title": "CVE Description"
        }
      ],
      "product_status": {
        "fixed": [
          "CSAFPID-0002",
          "CSAFPID-0004"
        ],
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0003"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "NVD - CVE-2024-48510",
          "url": "https://nvd.nist.gov/vuln/detail/CVE-2024-48510"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "date": "2025-01-10T06:30:00.000000Z",
          "details": "The vulnerability mentioned in this advisory has been corrected in Drive Composer version 2.9.1.\nDrive Composer version 2.9.1 (both entry and pro) is downloadable from the product page:\nhttps://new.abb.com/drives/software-tools/drive-composer\nABB recommends that customers apply the update at earliest convenience.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0003"
          ],
          "url": "https://new.abb.com/drives/software-tools/drive-composer"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "environmentalScore": 9.8,
            "environmentalSeverity": "CRITICAL",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "temporalScore": 9.8,
            "temporalSeverity": "CRITICAL",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0003"
          ]
        }
      ],
      "title": "CVE-2024-48510"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…