Summary
Schneider Electric CitectSCADA Products Exception Handler Vulnerability (Update A)

Notes

Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
CISA Disclaimer
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Recommended Practices
CISA recommends users take defensive measures to minimize the risk of exploitation.
Recommended Practices
Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Recommended Practices
Locate control system networks and remote devices behind firewalls and isolating them from business networks.
Recommended Practices
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Recommended Practices
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
Recommended Practices
CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.



{
  "document": {
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited",
      "tlp": {
        "label": "WHITE",
        "url": "https://us-cert.cisa.gov/tlp/"
      }
    },
    "lang": "en-US",
    "notes": [
      {
        "category": "legal_disclaimer",
        "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
        "title": "Legal Notice"
      },
      {
        "category": "general",
        "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
        "title": "CISA Disclaimer"
      },
      {
        "category": "general",
        "text": "CISA recommends users take defensive measures to minimize the risk of exploitation.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "Locate control system networks and remote devices behind firewalls and isolating them from business networks.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.",
        "title": "Recommended Practices"
      }
    ],
    "publisher": {
      "category": "coordinator",
      "contact_details": "central@cisa.dhs.gov",
      "name": "CISA",
      "namespace": "https://www.cisa.gov/"
    },
    "references": [
      {
        "category": "self",
        "summary": "ICS Advisory ICSA-13-350-01A JSON",
        "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2013/icsa-13-350-01a.json"
      },
      {
        "category": "self",
        "summary": "ICS Advisory ICSA-13-350-01A - Web Version",
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-13-350-01a"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/topics/industrial-control-systems"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014"
      }
    ],
    "title": "Schneider Electric CitectSCADA Products Exception Handler Vulnerability (Update A)",
    "tracking": {
      "current_release_date": "2025-06-06T18:43:53.863083Z",
      "generator": {
        "date": "2025-06-06T18:43:53.863018Z",
        "engine": {
          "name": "CISA CSAF Generator",
          "version": "1.0.0"
        }
      },
      "id": "ICSA-13-350-01A",
      "initial_release_date": "2013-09-18T06:00:00.000000Z",
      "revision_history": [
        {
          "date": "2013-09-18T06:00:00.000000Z",
          "legacy_version": "Initial",
          "number": "1",
          "summary": "Initial Publication"
        },
        {
          "date": "2025-06-06T18:43:53.863083Z",
          "legacy_version": "CSAF Conversion",
          "number": "2",
          "summary": "Advisory converted into a CSAF"
        }
      ],
      "status": "final",
      "version": "2"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version",
                "name": "v7.40",
                "product": {
                  "name": "Schneider Electric StruxureWare SCADA Expert Vijeo Citect: v7.40",
                  "product_id": "CSAFPID-0001"
                }
              }
            ],
            "category": "product_name",
            "name": "StruxureWare SCADA Expert Vijeo Citect"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003e=v7.20|\u003cv7.30SP1",
                "product": {
                  "name": "Schneider Electric Vijeo Citect: \u003e=v7.20|\u003cv7.30SP1",
                  "product_id": "CSAFPID-0002"
                }
              }
            ],
            "category": "product_name",
            "name": "Vijeo Citect"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003e=v7.20|\u003cv7.30SP1",
                "product": {
                  "name": "Schneider Electric CitectSCADA: \u003e=v7.20|\u003cv7.30SP1",
                  "product_id": "CSAFPID-0003"
                }
              }
            ],
            "category": "product_name",
            "name": "CitectSCADA"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003e=v7.30|\u003cv7.30SR1",
                "product": {
                  "name": "Schneider Electric StruxureWare PowerSCADA Expert: \u003e=v7.30|\u003cv7.30SR1",
                  "product_id": "CSAFPID-0004"
                }
              }
            ],
            "category": "product_name",
            "name": "StruxureWare PowerSCADA Expert"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003e=v7.20|\u003cv7.20SR1",
                "product": {
                  "name": "Schneider Electric PowerLogic SCADA: \u003e=v7.20|\u003cv7.20SR1",
                  "product_id": "CSAFPID-0005"
                }
              }
            ],
            "category": "product_name",
            "name": "PowerLogic SCADA"
          }
        ],
        "category": "vendor",
        "name": "Schneider Electric"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2013-2824",
      "cwe": {
        "id": "CWE-248",
        "name": "Uncaught Exception"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1, CitectSCADA 7.20 through 7.30SP1, StruxureWare PowerSCADA Expert 7.30 through 7.30SR1, and PowerLogic SCADA 7.20 through 7.20SR1 do not properly handle exceptions, which allows remote attackers to cause a denial of service via a crafted packet.",
          "title": "Vulnerability Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002",
          "CSAFPID-0003",
          "CSAFPID-0004",
          "CSAFPID-0005"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Some customers may have experienced a crash after applying the \u201csecurity \u0026 quality fix\u201d released on December 16, 2013. Schneider Electric has determined that the problem is within the quality portion of the fix. They have removed the quality fix from the release and have issued a new patch containing only the security update for this vulnerability.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005"
          ]
        },
        {
          "category": "mitigation",
          "details": "Schneider Electric has developed a cumulative patch that addresses the above security issue as well as a separate quality issue. These patches are available for all products affected: HF740RTM60777.1 for SCADA Expert Vijeo Citect v7.40, (http://www.citect.schneider-electric.com/se-vjc-HF740RTM607771), HF730SP160775.1 for Vijeo Citect v7.30 SP1, (http://www.citect.schneider-electric.com/vc-HF730SP1607751), HF720SP460769.1 for Vijeo Citect v7.20 SP4, (http://www.citect.schneider-electric.com/vc-HF720SP4607691), HF740RTM60777.1 for CitectSCADA v7.40, (http://www.citect.schneider-electric.com/cs-HF740RTM607771), HF730SP160775.1 for CitectSCADA v7.30 SP1, (http://www.citect.schneider-electric.com/cs-HF730SP1607751), HF720SP460769.1 for CitectSCADA v7.20 SP4, (http://www.citect.schneider-electric.com/cs-HF720SP4607691), HF730SP1608004 for PowerSCADA Expert v7.30 SR1, (http://www.citect.schneider-electric.com/pse-HF730SP160804), HF720SP460803 for PowerLogic SCADA v7.20 SR1, (http://www.citect.schneider-electric.com/pls-HF720SP460803)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005"
          ],
          "url": "http://www.citect.schneider-electric.com/se-vjc-HF740RTM607771"
        },
        {
          "category": "mitigation",
          "details": "Schneider Electric has developed a cumulative patch that addresses the above security issue as well as a separate quality issue. These patches are available for all products affected: HF740RTM60777.1 for SCADA Expert Vijeo Citect v7.40, (http://www.citect.schneider-electric.com/se-vjc-HF740RTM607771), HF730SP160775.1 for Vijeo Citect v7.30 SP1, (http://www.citect.schneider-electric.com/vc-HF730SP1607751), HF720SP460769.1 for Vijeo Citect v7.20 SP4, (http://www.citect.schneider-electric.com/vc-HF720SP4607691), HF740RTM60777.1 for CitectSCADA v7.40, (http://www.citect.schneider-electric.com/cs-HF740RTM607771), HF730SP160775.1 for CitectSCADA v7.30 SP1, (http://www.citect.schneider-electric.com/cs-HF730SP1607751), HF720SP460769.1 for CitectSCADA v7.20 SP4, (http://www.citect.schneider-electric.com/cs-HF720SP4607691), HF730SP1608004 for PowerSCADA Expert v7.30 SR1, (http://www.citect.schneider-electric.com/pse-HF730SP160804), HF720SP460803 for PowerLogic SCADA v7.20 SR1, (http://www.citect.schneider-electric.com/pls-HF720SP460803)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005"
          ],
          "url": "http://www.citect.schneider-electric.com/vc-HF730SP1607751"
        },
        {
          "category": "mitigation",
          "details": "Schneider Electric has developed a cumulative patch that addresses the above security issue as well as a separate quality issue. These patches are available for all products affected: HF740RTM60777.1 for SCADA Expert Vijeo Citect v7.40, (http://www.citect.schneider-electric.com/se-vjc-HF740RTM607771), HF730SP160775.1 for Vijeo Citect v7.30 SP1, (http://www.citect.schneider-electric.com/vc-HF730SP1607751), HF720SP460769.1 for Vijeo Citect v7.20 SP4, (http://www.citect.schneider-electric.com/vc-HF720SP4607691), HF740RTM60777.1 for CitectSCADA v7.40, (http://www.citect.schneider-electric.com/cs-HF740RTM607771), HF730SP160775.1 for CitectSCADA v7.30 SP1, (http://www.citect.schneider-electric.com/cs-HF730SP1607751), HF720SP460769.1 for CitectSCADA v7.20 SP4, (http://www.citect.schneider-electric.com/cs-HF720SP4607691), HF730SP1608004 for PowerSCADA Expert v7.30 SR1, (http://www.citect.schneider-electric.com/pse-HF730SP160804), HF720SP460803 for PowerLogic SCADA v7.20 SR1, (http://www.citect.schneider-electric.com/pls-HF720SP460803)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005"
          ],
          "url": "http://www.citect.schneider-electric.com/vc-HF720SP4607691"
        },
        {
          "category": "mitigation",
          "details": "Schneider Electric has developed a cumulative patch that addresses the above security issue as well as a separate quality issue. These patches are available for all products affected: HF740RTM60777.1 for SCADA Expert Vijeo Citect v7.40, (http://www.citect.schneider-electric.com/se-vjc-HF740RTM607771), HF730SP160775.1 for Vijeo Citect v7.30 SP1, (http://www.citect.schneider-electric.com/vc-HF730SP1607751), HF720SP460769.1 for Vijeo Citect v7.20 SP4, (http://www.citect.schneider-electric.com/vc-HF720SP4607691), HF740RTM60777.1 for CitectSCADA v7.40, (http://www.citect.schneider-electric.com/cs-HF740RTM607771), HF730SP160775.1 for CitectSCADA v7.30 SP1, (http://www.citect.schneider-electric.com/cs-HF730SP1607751), HF720SP460769.1 for CitectSCADA v7.20 SP4, (http://www.citect.schneider-electric.com/cs-HF720SP4607691), HF730SP1608004 for PowerSCADA Expert v7.30 SR1, (http://www.citect.schneider-electric.com/pse-HF730SP160804), HF720SP460803 for PowerLogic SCADA v7.20 SR1, (http://www.citect.schneider-electric.com/pls-HF720SP460803)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005"
          ],
          "url": "http://www.citect.schneider-electric.com/cs-HF740RTM607771"
        },
        {
          "category": "mitigation",
          "details": "Schneider Electric has developed a cumulative patch that addresses the above security issue as well as a separate quality issue. These patches are available for all products affected: HF740RTM60777.1 for SCADA Expert Vijeo Citect v7.40, (http://www.citect.schneider-electric.com/se-vjc-HF740RTM607771), HF730SP160775.1 for Vijeo Citect v7.30 SP1, (http://www.citect.schneider-electric.com/vc-HF730SP1607751), HF720SP460769.1 for Vijeo Citect v7.20 SP4, (http://www.citect.schneider-electric.com/vc-HF720SP4607691), HF740RTM60777.1 for CitectSCADA v7.40, (http://www.citect.schneider-electric.com/cs-HF740RTM607771), HF730SP160775.1 for CitectSCADA v7.30 SP1, (http://www.citect.schneider-electric.com/cs-HF730SP1607751), HF720SP460769.1 for CitectSCADA v7.20 SP4, (http://www.citect.schneider-electric.com/cs-HF720SP4607691), HF730SP1608004 for PowerSCADA Expert v7.30 SR1, (http://www.citect.schneider-electric.com/pse-HF730SP160804), HF720SP460803 for PowerLogic SCADA v7.20 SR1, (http://www.citect.schneider-electric.com/pls-HF720SP460803)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005"
          ],
          "url": "http://www.citect.schneider-electric.com/cs-HF730SP1607751"
        },
        {
          "category": "mitigation",
          "details": "Schneider Electric has developed a cumulative patch that addresses the above security issue as well as a separate quality issue. These patches are available for all products affected: HF740RTM60777.1 for SCADA Expert Vijeo Citect v7.40, (http://www.citect.schneider-electric.com/se-vjc-HF740RTM607771), HF730SP160775.1 for Vijeo Citect v7.30 SP1, (http://www.citect.schneider-electric.com/vc-HF730SP1607751), HF720SP460769.1 for Vijeo Citect v7.20 SP4, (http://www.citect.schneider-electric.com/vc-HF720SP4607691), HF740RTM60777.1 for CitectSCADA v7.40, (http://www.citect.schneider-electric.com/cs-HF740RTM607771), HF730SP160775.1 for CitectSCADA v7.30 SP1, (http://www.citect.schneider-electric.com/cs-HF730SP1607751), HF720SP460769.1 for CitectSCADA v7.20 SP4, (http://www.citect.schneider-electric.com/cs-HF720SP4607691), HF730SP1608004 for PowerSCADA Expert v7.30 SR1, (http://www.citect.schneider-electric.com/pse-HF730SP160804), HF720SP460803 for PowerLogic SCADA v7.20 SR1, (http://www.citect.schneider-electric.com/pls-HF720SP460803)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005"
          ],
          "url": "http://www.citect.schneider-electric.com/cs-HF720SP4607691"
        },
        {
          "category": "mitigation",
          "details": "Schneider Electric has developed a cumulative patch that addresses the above security issue as well as a separate quality issue. These patches are available for all products affected: HF740RTM60777.1 for SCADA Expert Vijeo Citect v7.40, (http://www.citect.schneider-electric.com/se-vjc-HF740RTM607771), HF730SP160775.1 for Vijeo Citect v7.30 SP1, (http://www.citect.schneider-electric.com/vc-HF730SP1607751), HF720SP460769.1 for Vijeo Citect v7.20 SP4, (http://www.citect.schneider-electric.com/vc-HF720SP4607691), HF740RTM60777.1 for CitectSCADA v7.40, (http://www.citect.schneider-electric.com/cs-HF740RTM607771), HF730SP160775.1 for CitectSCADA v7.30 SP1, (http://www.citect.schneider-electric.com/cs-HF730SP1607751), HF720SP460769.1 for CitectSCADA v7.20 SP4, (http://www.citect.schneider-electric.com/cs-HF720SP4607691), HF730SP1608004 for PowerSCADA Expert v7.30 SR1, (http://www.citect.schneider-electric.com/pse-HF730SP160804), HF720SP460803 for PowerLogic SCADA v7.20 SR1, (http://www.citect.schneider-electric.com/pls-HF720SP460803)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005"
          ],
          "url": "http://www.citect.schneider-electric.com/pse-HF730SP160804"
        },
        {
          "category": "mitigation",
          "details": "Schneider Electric has developed a cumulative patch that addresses the above security issue as well as a separate quality issue. These patches are available for all products affected: HF740RTM60777.1 for SCADA Expert Vijeo Citect v7.40, (http://www.citect.schneider-electric.com/se-vjc-HF740RTM607771), HF730SP160775.1 for Vijeo Citect v7.30 SP1, (http://www.citect.schneider-electric.com/vc-HF730SP1607751), HF720SP460769.1 for Vijeo Citect v7.20 SP4, (http://www.citect.schneider-electric.com/vc-HF720SP4607691), HF740RTM60777.1 for CitectSCADA v7.40, (http://www.citect.schneider-electric.com/cs-HF740RTM607771), HF730SP160775.1 for CitectSCADA v7.30 SP1, (http://www.citect.schneider-electric.com/cs-HF730SP1607751), HF720SP460769.1 for CitectSCADA v7.20 SP4, (http://www.citect.schneider-electric.com/cs-HF720SP4607691), HF730SP1608004 for PowerSCADA Expert v7.30 SR1, (http://www.citect.schneider-electric.com/pse-HF730SP160804), HF720SP460803 for PowerLogic SCADA v7.20 SR1, (http://www.citect.schneider-electric.com/pls-HF720SP460803)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005"
          ],
          "url": "http://www.citect.schneider-electric.com/pls-HF720SP460803"
        },
        {
          "category": "mitigation",
          "details": "Schneider Electric recommends all customers using the affected software packages listed above download and apply the relevant patch. They have published a notification that tells more about this security issue and a quality issue not discussed here. Customers with access may find it here: (http://www.citect.schneider-electric.com/security-DoS)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005"
          ],
          "url": "http://www.citect.schneider-electric.com/security-DoS"
        },
        {
          "category": "mitigation",
          "details": "SCADA Expert Vijeo Citect or CitectSCADA customers may contact the SCADA \u0026 MES Software Global Support Centre for more information at the following location: (http://www.citect.schneider-electric.com/contact-support)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005"
          ],
          "url": "http://www.citect.schneider-electric.com/contact-support"
        },
        {
          "category": "mitigation",
          "details": "PowerSCADA Expert or PowerLogic SCADA customers may contact their local country support organization at the following locations: (http://www2.schneider-electric.com/sites/corporate/en/support/support.page)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005"
          ],
          "url": "http://www2.schneider-electric.com/sites/corporate/en/support/support.page"
        },
        {
          "category": "mitigation",
          "details": "or (http://www.schneider-electric.com/sites/corporate/en/support/operations/local-operations/local-operations.page)",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005"
          ],
          "url": "http://www.schneider-electric.com/sites/corporate/en/support/operations/local-operations/local-operations.page"
        }
      ],
      "scores": [
        {
          "cvss_v2": {
            "baseScore": 7.8,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005"
          ]
        }
      ]
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…