gsd-2024-32303
Vulnerability from gsd
Modified
2024-04-13 05:02
Details
Tenda AC15 v15.03.20_multi, v15.03.05.19, and v15.03.05.18 firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function.
Aliases
{
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2024-32303"
],
"details": "Tenda AC15 v15.03.20_multi, v15.03.05.19, and v15.03.05.18 firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function.",
"id": "GSD-2024-32303",
"modified": "2024-04-13T05:02:29.106667Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2024-32303",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Tenda AC15 v15.03.20_multi, v15.03.05.19, and v15.03.05.18 firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/fromWizardHandle.md",
"refsource": "MISC",
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/fromWizardHandle.md"
}
]
}
},
"nvd.nist.gov": {
"cve": {
"descriptions": [
{
"lang": "en",
"value": "Tenda AC15 v15.03.20_multi, v15.03.05.19, and v15.03.05.18 firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function."
},
{
"lang": "es",
"value": "El firmware Tenda AC15 v15.03.20_multi, v15.03.05.19 y v15.03.05.18 tiene una vulnerabilidad de desbordamiento de pila ubicada a trav\u00e9s del par\u00e1metro PPW en la funci\u00f3n fromWizardHandle."
}
],
"id": "CVE-2024-32303",
"lastModified": "2024-04-17T16:51:07.347",
"metrics": {},
"published": "2024-04-17T16:15:08.837",
"references": [
{
"source": "cve@mitre.org",
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/fromWizardHandle.md"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Awaiting Analysis"
}
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…