          Campbell Scientific dataloggers CR6, CR300, CR800, CR1000 and CR3000 may allow an attacker to download configuration files, which may contain sensitive information about the internal network. From factory defaults, the mentioned datalogges have HTTP and PakBus enabled. The devices, with the default configuration, allow this situation via the PakBus port. The exploitation of this vulnerability may allow an attacker to download, modify, and upload new configuration files.
        
      Aliases
        
      Aliases
        
      {
  "GSD": {
    "alias": "CVE-2023-0321",
    "id": "GSD-2023-0321"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2023-0321"
      ],
      "details": "Campbell Scientific dataloggers CR6, CR300, CR800, CR1000 and CR3000 may allow an attacker to download configuration files, which may contain sensitive information about the internal network. From factory defaults, the mentioned datalogges have HTTP and PakBus enabled. The devices, with the default configuration, allow this situation via the PakBus port. The exploitation of this vulnerability may allow an attacker to download, modify, and upload new configuration files.",
      "id": "GSD-2023-0321",
      "modified": "2023-12-13T01:20:23.159681Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "cve-coordination@incibe.es",
        "DATE_PUBLIC": "2023-01-17T12:00:00.000Z",
        "ID": "CVE-2023-0321",
        "STATE": "PUBLIC",
        "TITLE": "Disclosure of Sensitive Information on Campbell Scientific Products"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "CR6",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "all version"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "CR300",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "all version"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "CR800",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "all version"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "CR1000",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "all version"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "CR3000",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "all version"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Campbell Scientific"
            }
          ]
        }
      },
      "credit": [
        {
          "lang": "eng",
          "value": "Carlos Antonini Cepeda"
        }
      ],
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "Campbell Scientific dataloggers CR6, CR300, CR800, CR1000 and CR3000 may allow an attacker to download configuration files, which may contain sensitive information about the internal network. From factory defaults, the mentioned datalogges have HTTP and PakBus enabled. The devices, with the default configuration, allow this situation via the PakBus port. The exploitation of this vulnerability may allow an attacker to download, modify, and upload new configuration files."
          }
        ]
      },
      "generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "impact": {
        "cvss": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 9.1,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
          "version": "3.1"
        }
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://www.incibe-cert.es/en/early-warning/ics-advisories/disclosure-sensitive-information-campbell-scientific-products",
            "refsource": "CONFIRM",
            "url": "https://www.incibe-cert.es/en/early-warning/ics-advisories/disclosure-sensitive-information-campbell-scientific-products"
          },
          {
            "name": "https://www.hackplayers.com/2023/01/cve-2023-0321-info-sensible-campbell.html",
            "refsource": "CONFIRM",
            "url": "https://www.hackplayers.com/2023/01/cve-2023-0321-info-sensible-campbell.html"
          }
        ]
      },
      "source": {
        "advisory": "INCIBE-2023-0017",
        "defect": [
          "INCIBE-2022-0040"
        ],
        "discovery": "EXTERNAL"
      },
      "work_around": [
        {
          "lang": "eng",
          "value": "HTTP can be disabled or secured through username/password, and Pakbus can be secured through the use of PakBus encryption key and/or PakBus/TCP password. Campbell Scientific offers a guide with instructions to maximize the security of all Internet connectivity of the affected devices (see more in the references)."
        }
      ]
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:campbellsci:cr6_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:campbellsci:cr6:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:campbellsci:cr300_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:campbellsci:cr300:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:campbellsci:cr800_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:campbellsci:cr800:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:campbellsci:cr1000_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:campbellsci:cr1000:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:campbellsci:cr3000_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:campbellsci:cr3000:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "cve-coordination@incibe.es",
          "ID": "CVE-2023-0321"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "Campbell Scientific dataloggers CR6, CR300, CR800, CR1000 and CR3000 may allow an attacker to download configuration files, which may contain sensitive information about the internal network. From factory defaults, the mentioned datalogges have HTTP and PakBus enabled. The devices, with the default configuration, allow this situation via the PakBus port. The exploitation of this vulnerability may allow an attacker to download, modify, and upload new configuration files."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-200"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.incibe-cert.es/en/early-warning/ics-advisories/disclosure-sensitive-information-campbell-scientific-products",
              "refsource": "CONFIRM",
              "tags": [
                "Mitigation",
                "Third Party Advisory"
              ],
              "url": "https://www.incibe-cert.es/en/early-warning/ics-advisories/disclosure-sensitive-information-campbell-scientific-products"
            },
            {
              "name": "https://www.hackplayers.com/2023/01/cve-2023-0321-info-sensible-campbell.html",
              "refsource": "CONFIRM",
              "tags": [
                "Exploit",
                "Third Party Advisory"
              ],
              "url": "https://www.hackplayers.com/2023/01/cve-2023-0321-info-sensible-campbell.html"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          },
          "exploitabilityScore": 3.9,
          "impactScore": 5.2
        }
      },
      "lastModifiedDate": "2023-02-06T16:42Z",
      "publishedDate": "2023-01-26T21:18Z"
    }
  }
}
  Loading…
      Loading…
      Sightings
| Author | Source | Type | Date | 
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
 - Confirmed: The vulnerability is confirmed from an analyst perspective.
 - Published Proof of Concept: A public proof of concept is available for this vulnerability.
 - Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
 - Patched: This vulnerability was successfully patched by the user reporting the sighting.
 - Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
 - Not confirmed: The user expresses doubt about the veracity of the vulnerability.
 - Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
 
Loading…
      Loading…